Search Result 264, Processing Time 0.025 seconds

Design of a LTCC Front End Module with Power Detecting Function (전력 검출 기능을 포함하는 LTCC 프런트 엔드 모듈 설계)

  • Hwang, Mun-Su;Koo, Jae-Jin;Koo, Ja-Kyung;Lim, Jong-Sik;Ahn, Dal;Yang, Gyu-Yeol;Kim, Jun-Chul;Kim, Dong-Su;Park, Ung-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.844-853
    • /
    • 2008
  • This paper describes the design of a FEM(Front End Module) having power detection function for mobile handset application. The designed FEM consists of a MMIC(Monolithic Microwave Integrated Circuits) power amplifier chip, SAW Tx filter and duplexer, diode power detector and stripline matching circuit. An LTCC(Low Temperature Co-fired Ceramics) technology is adopted for miniaturized FEM. The frequency band is $824{\sim}869$ MHz which is the uplink Tx band of the CDMA mobile system. The size of designed FEM is $7.0{\times}5.5{\times}1.5\;mm^3$, which is an ultra-small size even though the power detector circuit is included. All sub-components of FEM have been developed and measured in advance before being integrated into FEM. The measured output power and gain are 27 dBm and 27 dB, respectively. In addition, the measured ACPR characteristics are 46.59 dBc and 55.5 dBc at 885 kHz and 1.98 MHz offset, respectively.

Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator (배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF

Comparison of Vibration Characteristics in IPM and SPM BLDC Motors with Rotor Eccentricity : (1) Electro-magnetic Force Due to PM (회전자 편심을 가지는 IPM, SPM 전동기 진동 특성 비교: (1) 영구 자석에 의한 전자기력)

  • 황근배;김경태;황상문
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.454-461
    • /
    • 2001
  • Acoustic noise and vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and electromagnetic origins through the motor air-gap. When a relative misalignment of rotor in the air-gap center exists on the assemblage, it is considered to influence the motor system characteristics. In this paper, the back electro motive force(BEMF) is analyzed by Finite Element Method(FEM) and verified by experiments for the SPM and IPM type motors. For magnetic field analysis, a FEM is used to account for the magnetic saturation. Using these results, the FEM is made to determine the appropriate electromagnetic field analysis in BLDC motors with rotor eccentricity ratio. A radial magnetic imbalance force of BLDC motor with rotor eccentricity is analyzed. Results demonstrate that the imbalance force is increased according to the degree of misalignment. An IPM motor, mostly chosen to realize high-speed operation, shows a worse effect on magnetic unbalanced forces and dynamic responses compared with SPM motor due to magnetic saturation when the rotor eccentricity exists.

  • PDF

Analysis of Dynamic Characteristics of Electromagnetic Suspension system with Lateral Displacement by FEM (FEM에의한 부상마그네트의 횡방향 편위를 고려한 자기부상시스템의 안내력변화 특성해석)

  • Im, Dal-Ho;Kwon, Byung-Il;Hong, Jung-Pyo;Im, Jee-Won
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.570-572
    • /
    • 1992
  • In this paper, an analysis of lift and lateral forces as a function of speed in electromagnetic suspension system (EMS) using the finite element method is presented. It is shown that, as in the case of the lift force, the lateral restoring force decreases with increasing speed, and the lateral dynamic characterisitic for lateral disturbance at low speed is different from that at high speed.

  • PDF

A FEM Analysis of Remote Field Eddy Current Distribution to CANDU Fuel Channel Tube(I) (CANDU형 핵연료 채널 압력관에 대한 원거리장 와전류의 자계분포 특성해석(I))

  • Huh, Hyung;Jung, Hyun-Kyu;Kim, Kern-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.690-692
    • /
    • 2001
  • A FEM model of the remote-field eddy current effect is presented for zirconium-2.5percent niobium(Zr-2.5%Nb) nuclear reactor pressure tubes to demonstrate the important electromagnetic field. Phenomena that describe this effect. This model is applied to evaluate the optimal operating frequency and detector position. There are many ambiguous experimental results connected with this technique. Finite element calculations can be used in the interpretation of these experimental results even though the electromagnetic fields measured in the remote-field technique are very small.

  • PDF

The Insulation Design of Enclosure for Diagnostic Device in Extra High Voltage Line (초고압 선로 진단장치용 외함 절연설계)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, in order to avoid equipment malfunction due to electromagnetic waves, which can occur when high-voltage live line diagnostic device fabrication, the enclosure structure of the diagnostic device with power lines that can minimize the EMI (electromagnetic interference) was modeled using the FEM (finite element method). Simulation examined the strength of the electric field in the required thickness, material and regions where there is a control board while changing the curvature radius of the corner making the enclosure, and By applying a mechanical design and simulation results that occur during the actual production has been designed for the final design. Most of the simulation results for the electric field is concentrated in the final model, the inner edge of the enclosure could be confirmed that the stable structure.

Investigation on Radiation Characteristics of 42″ AC-PDP (42″ AC-PDP의 방사특성에 대한 연구)

  • Lim Heon-Yong;Kim Min-Seok;Park Dongwook;Lee Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.841-847
    • /
    • 2004
  • EMI emission characteristics of 42" AC-PDP panel are investigated in this paper. First, EMI emission source was modeled the scan electrode and the sustain electrode to a simple electric and magnetic dipole type radiator. Second, EMI emission source was modeled as reconfigured the scan electrode and the sustain electrode. The primary source of EMI emission was investigated using FEM calculation of the wave impedance and 3 dB beam width. The third. the EMI emission level was estimated using the measured sustain electrode current. Also, EMI emission level of 42" AC-PDP was measured. The results show that the calculated EMI emission level from the simple electric dipole model was shown to agree with that from the corresponding FEM simulation.

A Mathematical and Physical Model for the Design of a Single Stage Coilgun (단일 스테이지 코일건 설계를 위한 수학적 및 물리적 모델)

  • Kim, Ji-Hun;Jeon, Sang-Woon;Kim, Joonyun
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.74-82
    • /
    • 2013
  • This paper deals with a single stage coilgun which is a variety of EML(ElectroMagnetic Launcher) and can be applied to launching a small satellite. We propose a mathematical and physical model in order to design a single stage coilgun and study physical characteristics related to design parameters. A proposed mathematical and physical model is verified by electromagnetic FEM software FEMM 4.2.

Electromagnetic Field Analysis based on Java Multi-Threads (자바 스레드 기반 고속 전자계 해석)

  • Kim, Tae Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.53-55
    • /
    • 2013
  • In general, various numerical techniques such as MoM, TLM, FEM, and BEM can be introduced to analyze some microwave device and electromagnetic propagation problems. Numerical simulator based on Java thread-level parallelism for improving computation performance is implemented and estimated.

  • PDF

Analysis of the Electromagnetic Phenomena in Vacuum Interrupter with Axial Magnetic Field Type (축자계형 진공인터럽터의 전자계 현상 해석)

  • 하성철;서상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.952-957
    • /
    • 2003
  • The purpose of this paper is analyses about in 12kV/50kA vacuum interrupter with an axial magnetic field type electrode system through the studies of electromagnetic phenomena. Vacuum interrupter is important in electric safety part. In this paper, we performed analysis of electric field, magnetic field, current density in AMF electrode using the Maxwell 3D simulation. The current distribution and magnetic field in simple models are analyzed to verify its efficiency and accuracy. In addition the validity of FEM is confirmed by performing the analyses of distribution in current density and magnetic flux density.