• 제목/요약/키워드: Electromagnetic Circuit

검색결과 1,153건 처리시간 0.038초

전자기 션트 감쇠기를 이용한 빔의 진동억제에 관한 연구 (Vibration Suppression of Beam by Using Electromagnetic Shunt Damper)

  • 성태홍;임승현;오일권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.77-80
    • /
    • 2008
  • In this paper the electromagnetic shunt damper was newly employed for vibration suppression of the flexible structures. The electromagnetic shunt damper consists of a coil and a permanent magnet. The ends of the coil were connected to the RLC shunt circuit. The numerical solutions of resonant frequency of the shunt circuits were calculated by using Pspice. The vibration and damping characteristics of the flexible beams with the electromagnetic shunt damper were investigated by tuning the circuit parameters. Also, the effect of the magnetic intensity on the shunt damping was studied with the variation of the gap between the aluminum beam and the permanent magnet. Present results show that the magnet shunt damper can be successfully applied to reduce the vibration of the flexible structures.

  • PDF

Electromagnetic Susceptibility Analysis of I/O Buffers Using the Bulk Current Injection Method

  • Kwak, SangKeun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권2호
    • /
    • pp.114-126
    • /
    • 2013
  • In this paper, we present a set of methodologies to model the electromagnetic susceptibility (EMS) testing of I/O buffers for mobile system memory based on the bulk current injection (BCI) method. An efficient equivalent circuit model is developed for the current injection probe, line impedance stabilization network (LISN), printed circuit board (PCB), and package. The simulation results show good correlation with the measurements and thus, the work presented here will enable electromagnetic susceptibility analysis at the integrated circuit (IC) design stage.

외부 전자파의 입사방향에 대한 각진 두 스트립으로 구성된 전송선의 반응, I:회로개념의 해석 (Response of angled two-strip transmission lines to the incdent angle of an external electromagnetic field, I : Circuit-concept analysis)

  • 홍성용;김세윤;라정웅
    • 한국전자파학회지:전자파기술
    • /
    • 제3권2호
    • /
    • pp.3-9
    • /
    • 1992
  • The reponse of the angled two-strip transmission lines illuminated by an external electromagnetic field is estimated by using the circuit concept approach. Calculated terminal voltages reveal convergence to a fixed value as the number of discretization increases. The amplitude patterns of two terminal voltages to all the direction and polarization of the incident field are also calculated.

  • PDF

Electromagnetic Actuator with Novel Electric Brake for Circuit Breaker

  • Bae, Byungjun;Kim, Minjae
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.340-347
    • /
    • 2016
  • At the stroke end of an electromagnetic circuit breaker, the high speed of the mover makes a huge impact at the contact point, which induces the rebound problem of the mover that causes a breaker failure. Thus, a speed reduction equipment is required to address such problems. This study suggests to use an electric brake reduces the speed at the end of the stroke. The proposed circuit breaker which adopts the electric brake has a variable speed reduction function such that the continued rebound phenomenon ceases to occur. The electric brake is designed by the Finite Element Method (FEM) and the circuit and motion equations are solved using Time Difference Method (TDM). The comparisons between the simulation and experiments demonstrated the usefulness and validity of this study.

Analysis of Magnetically Coupled Wireless Power Transmission for Maximum Efficiency

  • Kim, Chung-Ju;Lee, Bom-Son
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.156-160
    • /
    • 2011
  • We have proposed and analyzed an equivalent circuit for a magnetically coupled wireless power transmission (WPT) system between two loop resonators by considering its coupling coefficient and radiation-related parameters. A complete formulation is provided for all the necessary circuit parameters. The mechanism of radiation loss is sufficiently explained. The circuit and electromagnetic (EM) simulation results have been shown to be in good agreement. Based on the proposed circuit formulation, a specific load impedance for maximum WPT efficiency was found to exist. The proposed modeling of the WPT in terms of circuit characterizations provides sufficient insight into the problems associated with WPT.

전자장 해석을 통한 보호 개전기용 CT 설계 (Design of CT used Protection Relay by Electromagnetic Field Analysis)

  • 손종만;송희찬;최종웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.155-158
    • /
    • 1997
  • In design of current transformer, equivalent circuit parameters is obtained by electromagnetic analysis and used circuit simulation. Precise core secton area and turns of coil can be determined by circuit analysis. Therefore exact design of current transformer is possible by field and circuit analysis.

  • PDF

Noise Injection Path의 주파수 특성을 고려한 IC의 전자파 전도내성 시험 방법에 관한 연구 (Evaluation of IC Electromagnetic Conducted Immunity Test Methods Based on the Frequency Dependency of Noise Injection Path)

  • 곽상근;김소영
    • 한국전자파학회논문지
    • /
    • 제24권4호
    • /
    • pp.436-447
    • /
    • 2013
  • 본 논문에서는 IC(Integrated Circuit) 전자파 전도내성 시험 방법인 BCI(Bulk Current Injection)와 DPI(Direct Power Injection)를 이용하여 1.8 V I/O 버퍼에 대한 IC 전자파 전도내성을 시험하였다. IC 전자파 전도내성 시험을 회로 해석기를 사용하여 시뮬레이션 할 수 있는 등가회로 모델(model)을 개발하고 검증하였다. BCI와 DPI의 주파수에 따른 forward 전력을 비교한 결과는 주파수 성분에 따라 실제 IC에 도달하는 전자파(electromagnetic, EM) 노이즈의 양이 제한됨을 보여준다. 시뮬레이션을 통해, 가해지는 RF(Radio Frequency) 노이즈가 전달되는 경로의 삽입손실을 구하여, 하나의 시험 방법만으로는 넓은 주파수 영역에서 실질적인 IC 전자파 내성시험의 어려움을 발견하였다. 따라서 규정된 시험 방법을 보완하여 넓은 주파수 영역의 노이즈에 대해 신뢰도 높은 IC 전자파 전도내성 시험 방법을 제안한다.

VOF 방법을 이용한 GMA 용접의 금속 이행에 관한 동적 해석 (II) - 단락 이행 모드의 해석 - (Dynamic Analysis of Metal Transfer using VOF Method in GMAW (II) - Short Circuit Transfer Mode -)

  • 최상균;고성훈;유중돈;김희진
    • Journal of Welding and Joining
    • /
    • 제15권3호
    • /
    • pp.47-55
    • /
    • 1997
  • Dynamic characteristics of the short circuit mode are investigated using the Volume of Fluid (VOF) method. When the initial molten drop volume, contact area and wire feed rate are given, rate change of the molten bridge profiles, pressure and velocity distributions are predicted. The electromagnetic force with proper boundary conditions are included in the formulation to consider the effects of welding current. It is found that the molten metal is transferred to the weld pool mainly due to the pressure difference caused by the curvatures in the initial stage, and electromagnetic force becomes dominant factor in the final stage of short circuit transfer. Necking occurs at the contact position between the molten drop and weld pool, and the initial molten drop volume and welding current have significant effects on break-up time.

  • PDF

A Simple Model for a DGS Microstrip Line with Stepped Impedance Slot-Lines

  • Woo, Duk-Jae;Lee, Taek-Kyung;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • 제15권1호
    • /
    • pp.26-30
    • /
    • 2015
  • In this paper, a simple equivalent circuit model for a defected ground structure (DGS) microstrip line with stepped impedance slot-lines in the ground plane is presented. In addition, an analytic expression for the resonance frequency of the proposed structure is derived. In equivalent circuit modeling, the capacitance and the inductance of the resonance circuit are evaluated from the dimensions of the etched pattern in the ground plane. The resonance frequencies calculated from the proposed method are compared with those obtained with an electromagnetic (EM) simulation.

케이블 삼상단락 실증시험을 통한 전자력 영향 검토 (The Study of Electromagnetic Force by Three Phase Short-Circuit Test of Cable)

  • 홍동석;김해준;박성민;장우석;박흥석;장태인;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.395_396
    • /
    • 2009
  • This paper handles with effect of electromagnetic force on the cables by fault current accompanied by accident of underground transmission cable. Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper describes the effect of electromagnetic force through results of three phase short-circuit test and electromagnetic force analysis using theoretical calculations and electrical evaluation test after three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF