• Title/Summary/Keyword: Electrolyte Balance

검색결과 61건 처리시간 0.038초

A Study on the Development of an Instrument for Evaluating the Quality of Nursing Care (간호의 질 평가도구 개발에 관한 일 연구)

  • 유지수
    • Journal of Korean Academy of Nursing
    • /
    • 제7권2호
    • /
    • pp.11-21
    • /
    • 1977
  • Many in nursing look back on Nursing Research history and proudly point to the fact that emphasis in nursing research has changed from studying the nurse to studying nursing practice. In recent years, much emphasis has been placed on seeking a method of evaluating the quality of nursing care. In spite of these attempts, however, an instrument for evaluating the quality of nursing care that is actually applicable in the clinical area has not been found. The Purposes of this study are as follows: 1) To develop the instrument to be used in evaluating the quality of nursing care provided in the Neuro - Surgery Constant Care Unit of Severance Hospital 2) To evaluate the quality of nursing care in the clinical area. 3) To provide the necessary information for improvement of quality of nursing care. The instrument for evaluating the quality of nursing care, developed by the investigator, was composed of 7 nursing goals and divided into 65 standards of nursing performance. The 7 nursing goal are as follows : 1) Maintenance of airway 2) Maintenance of fluid at electrolyte balance 3) Maintenance of elimination 4) Personal hygiene 5) Optimum activity 6) Prevention of accidents 7) Emotional care The study population defined was composed of all the case (51) who were admitted in the Neuro- Surgery Constant Care Unit of Severance Hospital from May 7-13, 1976. The observation method was used and the data was subjected to the %, X²-test, T-test, F-test and Correlation. The results of tile study were as follows : 1. Levels of nursing performance regarding nursing goals. Seven different nursing care indices were constructed in terms of nursing goals. The index scores were grouped arbitrarily into ,j categories such as "excellent", "good", "moderate", "incomplete", and "poor"based upon the investigator′s personal judgement. a. The nursing index of maintaining airway showed that 78% of the patients fell within the "excellent" and 22% of the patients, fell within the "good" category. b. The nursing index of maintaining fluid & electrolyte balance showed that 95% of the patients fell within the "excellent" and 5 % of the patients fell within the "good" category. c. The nursing index of maintaining elimination showed that 100% of the patients fell within the "excellent" category. d. The nursing index of personal hygiene revealed that 49% of the patients fell within the "excellent" and 51% of the patients fell within the "good" category. e. The nursing index of optimum activity showed that 63% of the patients fell within the "excellent" and 32% of the patients fell within tile "good" and 5% of patients fell within the "moderate" category. f. The nursing index of prevention of accidents showed that 100% of the patients foil within the "excellent" category. g. The nursing index of emotional cart revealed that 27% of the patients fell within the "excellent", 24 % of the patients fell within tile "good", 29 % of the patients fell within the "incomplete" category. From these findings it is disclosed that the quality of nursing care provided in the Neuro- Surgery Constant Care Unit of Severance Hospital was excellent. h. There were statistically significant differences between the nursing index of physical care and emotional care. (t=8.73, D. F. =100. p<0.01) It is revealed that more physical care then emotional care was carried out by nurses. 2. Levels of nursing performance regarding general characteristics of the patients. No significant differences were observed statistically with the nursing indices of nursing goals according to the sex (t=0.084, D. F. =12, p>0.05). Age (F=0.1251, D. F. : 3.18. p 〉0.05), absence or presence of operating experiences (t=0.6032, D. F. =12, p〉0.05, levels of consciousness (F=0.31, D. F. :3. 18, p >0.05) 3. Relationship between the levels of consciousness and the nursing index of each nursing goal. There was negative correlation between the levels of consciousness and the nursing index of maintaining airway (r=-0. 5449, p<0.01) and personal hygiene (r= -0.4075, p<0.01) There was positive correlation between the levels of consciousness and the nursing index of optimum activity (r=0.3936, p <0.01) and emotional care (r=0.7819, p〈0.01). There was slight correlation between the levels of consciousness and the nursing index of maintaining fluid & electrolyte balance (r=-0.3418, 0.010.05) and preventing accidents (r=0.1441, p>0.05.

  • PDF

Development of a 25kW-Class PEM Fuel Cell System for the Propulsion of a Leisure Boat (선박 추진용 25kW급 고분자전해질 연료전지 시스템 개발)

  • Han, In-Su;Jeong, Jeehoon;Kho, Back-Kyun;Choi, Choeng Hoon;Yu, Sungju;Shin, Hyun Khil
    • Journal of Hydrogen and New Energy
    • /
    • 제25권3호
    • /
    • pp.271-279
    • /
    • 2014
  • A 25kW-class polymer electrolyte membrane (PEM) fuel cell system has been developed for the propulsion of a leisure boat. The fuel cell system was designed to satisfy various performance requirements, such as resistance to shock, stability under rolling and pitching oscillations, and durability under salinity condition, for its marine applications. Then, the major components including a 30kW-class PEM fuel cell stack, a DC-DC converter, a seawater cooling system, secondary battery packs, and balance of plants were developed for the fuel cell system. The PEM fuel cell stack employs a unique design structure called an anodic cascade-type stack design in which the anodic cells are divided into several blocks to maximize the fuel utilization without hydrogen recirculation devices. The performance evaluation results showed that the stack generated a maximum power of 31.0kW while maintaining a higher fuel utilization of 99.5% and an electrical efficiency of 56.1%. Combining the 30-kW stack with other components, the 25kW-class fuel cell system boat was fabricated for a leisure. As a result of testing, the fuel cell system reached an electrical efficiency of 48.0% at the maximum power of 25.6kW with stable operability. In the near future, two PEM fuel cell systems will be installed in a 20-m long leisure boat to supply electrical power up to 50kW for propelling the boat and for powering the auxiliary equipments.

Treatment of chronic kidney disease in children (소아의 만성신장질환의 치료)

  • Lee, Joo Hoon
    • Clinical and Experimental Pediatrics
    • /
    • 제52권10호
    • /
    • pp.1061-1068
    • /
    • 2009
  • The treatment of pediatric patients with chronic renal disease comprises management of nutritional imbalance, fluid, electrolyte, and acid-base disturbances, mineral bone disease, anemia, hypertension, and growth retardation. The treatment also includes administration of appropriate renal replacement therapy, if required. Adequate dietary intake of carbohydrates, fats, and proteins and caloric intake must be encouraged in such patients to ensure proper growth and development. In addition, fluid, electrolyte, and acid-base status must be regularly monitored and should be well maintained. Serum calcium, phosphorus, and parathyroid hormone levels must be maintained at their target range, which are determined on the basis of the glomerular filtration rate, to avoid the development of mineral bone disease. This can be achieved by using phosphorus binders and vitamin D analogues. An erythropoiesis-stimulating agent must be administered along with iron supplementation to maintain the hemoglobin level of the patients between 11-12 g/dL. Hypertension must be controlled with adequate water and sodium balance and appropriate antihypertensive agents. Administration of recombinant human growth hormone is recommended to improve the final adult heights.

SIADH Caused by the Synergistic Effect of S-1 and Thiazide (S-1과 티아지드 상승효과에 의한 항이뇨호르몬과다분비증후군 1예)

  • Ha, Tae-Kyung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • 제6권3호
    • /
    • pp.198-201
    • /
    • 2006
  • Hyponatremia is a dangerous electrolyte disturbance in patients on chemotherapy and may cause sudden death if not detected early. SIADH (syndrome of inappropriate antidiuretic hormone) is one of the known causes of hyponatremia in patients undergoing chemotherapy. Few chemotherapeutic agents, however, are reported to cause SIADH. The current study reports that SIADH developed in a 55 year old woman on S-1 ($80\;mg/m^{2}$) and cisplatin ($60\;mg/m^{2}$) chemotherapy for the peritoneal metastasis of gastric cancer. The patient underwent a total gastrectomy, a splenectomy, and a segmental resection of the transverse colon for gastric cancer. She had used thiazide and ${\beta}-blocker$ to treat hyperiension for 12 years. She admitted to our hospital with complaining of general weakness, dysarthria, loss of appetite, and urinary discomfort. The serum level of sodium and potassium were 94 mEq/L and 2.2 mEq/L respectively. The hyponatremia completely resolved uneventfully after 3% saline infusion, which led to normalized electrolyte balance. The patient was discharged on the 13th hospital day.

  • PDF

The Effect of Thermal Management on the Performance of a Polymer Electrolyte Membrane Fuel Cell System (PEMFC의 열관리가 시스템의 성능에 미치는 영향)

  • Lee, Jeong-Ho;Myung, No-Sung;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제35권6호
    • /
    • pp.593-601
    • /
    • 2011
  • An analysis program to simulate the operation of a polymer electrolyte membrane fuel cell (PEMFC) system was set up, and system operation with variations in the working conditions of various components (especially the thermal management system) was simulated. The entire system included a PEMFC stack and balance-of-plant components such as an air-supply unit, a fuel-supply unit, and a heat-management unit (cooling system). Thermodynamic models of all components were made to evaluate the design performance of the entire system, and then off-design models were set up to simulate the operation of the entire system under arbitrary working conditions. A parametric study was carried out to examine the effects of varying the operating conditions (especially the ambient conditions and the operating conditions of the cooling system) on the operation and performance of the entire system.

Effect of Oral Administration of DiakurTM (a Glucose and Electrolytes Additive) on Growth and Some Physiological Responses in Broilers Reared in a High Temperature Environment

  • Takahashi, Kazuaki;Akiba, Yukio
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권9호
    • /
    • pp.1341-1347
    • /
    • 2002
  • An experiment was conducted to determine effects of oral administration of $Diakur^{TM}$ (an additive of glucose and electrolytes for young calves) on growth performance and some physiological responses in male broilers reared in a high temperature. A 2 by 3 factorial arrangement test of 2 temperatures (24 and $36^{\circ}C$) and 3 levels of oral administration of the glucose and electrolytes additive, $Diakur^{TM}$, (0, 150 and 300 mg/day/100 gBW) were applied in the experiment. Male broiler chicks (2 weeks of age) were assigned to six groups and received dietary and temperature treatments for 7 days. The additive of glucose and electrolytes was suspended with water and intubated into crop twice a day (08:00 and 17:00). Oral administration of the additive prevented decreases in food intake and growth rates in broilers due to exposure of the hot environment. Oral administration of the additive also improved a lowered electrolyte ($Na^+$ + $K^+$ - $Cl^-$) balance in plasma, low mitogenic response of blood mononuclear cell and an increase in glucose concentration due to exposure to the high environmental temperature. Oral administration of the additive increased rectal temperature regardless of environmental temperatures. On the other hand, blood pH, $pCO_2$ and $HCO_3$ - concentration, and plasma creatine kinase activity were not affected by the oral administration. The results suggested that oral administration of the glucose and electrolytes additive, $Diakur^{TM}$ during heat stress did not only prevent decrease in growth performance, but also normalized some physiological and immunological responses in male broilers.

Study on Validity of 1-D Spherical Model on Aqua-plasma Power Estimation With Electrode Structure

  • Yun, Seong-Yeong;Jang, Yun-Chang;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.74-74
    • /
    • 2010
  • The aqua-plasma is the non-thermal plasma in electrical conductive electrolyte by generates the vapor film layer on the immersed metal electrode surface. This plasma can generate the hydroxyl radical by dissociate the water molecule with the plasma electron. To develop the plasma discharge device for high efficiency in the hydroxyl radical generation, proper model for estimation of plasma power is necessary. In this work, the 1-D spherical model was developed, considering temperature dependence material constants. The relation between the plasma power and hydroxyl generation was also studied by the comparison between the optical emission intensity from the hydroxyl radical using monochromator and estimated plasma power. First, the thickness of vapor layer thickness was estimated using the Navier-Stokes fluid equation in order to calculate the discharge E-field inside vapor layer. Using the E-field magnitude and power balance on the plasma generation, it was possible to estimate the plasma power. The plasma power was assumed to uniformly fill the vapor layer and the temperature of vapor layer was fixed in the boiling temperature of electrolyte, 375K. In the experiment, the aqua-plasma was discharged in the saline by applied the voltage on the bipolar electrode. The range of applied voltage was 234 to 280V-rms in the frequency of 380 kHz. Two type electrodes were produced with two ${\Phi}0.2$ tungsten. The plasma power was estimated from the V-I signal from the two high voltage probes and current probe. The estimated plasma power agreed with the profile of emission intensity when the plasma discharged between the metal electrode and vapor layer surface. However, when the plasma discharged between the metal electrodes, the increasing rate of emission intensity was lower than the increase of plasma power. It implies that the surface reaction is more sufficient rather than the volume reaction in the radical generation, due to the high density of water molecule in the liquid.

  • PDF

Evaluation of Durability for Al Alloy with Anodizing Condition (알루미늄 합금의 양극산화 조건에 따른 내구성 평가)

  • Lee, Seung-Jun;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.152-152
    • /
    • 2016
  • Anodizing is a technology to generate thicker and high-quality films than natural oxide films by treating metals via electrochemical methods. It is a technique to develop metals for various uses, and extensive research on the commercial use has been performed for a long time. Aluminum anodic oxide (AAO) is generate oxide films, whose sizes and characteristics depending on the types of electrolytes, voltages, temperatures and time. Electrochemical manufacturing method of nano structure is an efficient technology in terms of cost reduction, high productivity and complicated shapes, which receives the spotlight in diverse areas. The sulfuric acid was used as an anodizing electrolyte, controlling its temperature to $10^{\circ}C$. The anode was 5083 Al alloy with dimension of $5(t){\times}20{\times}20mm$ while the cathode was the platinum. The distance between the anode and the cathode was maintained at 3 cm. Agitation was introduced by magnetic stirrer at 300 rpm to prevent localized temperature rise that hinders stable growth of oxide layer. In order to observe surface characteristics with applied current density, the electrolyte temperature, concentration was maintained at constant condition for $10^{\circ}C$, 10 vol.%, respectively. To prevent hindrance of stable growth of oxide layer due to local temperature increase during the experiment, stirring was maintained at constant rate. In addition, using galvanostatic method, it was maintained at current density of $10{\sim}30mA/cm^2$ for 40 minutes. The cavitation experiment was carried out with an ultrasonic vibratory apparatus using piezo-electric effect with modified ASTM-G32. The peak-to-peak amplitude was $30{\mu}m$ and the distance between the horn tip and specimen was 1 mm. The specimen after the experiment was cleaned in an ultrasonic, dried in a vacuum oven for more than 24 hours, and weighed with an electric balance. The surface damage morphology was observed with 3D analysis microscope. As a result of the investigation, differences were observed surface hardness and anti-cavitation characteristics depending on the development of oxide film with applied current density.

  • PDF

Modeling of PEM Fuel Cell System-Sensitivity Analysis of System Efficiency with Different Main Operating Parameters of Automotive Fuel Cell System (PEM 연료전지 시스템 모델링-자동차용 연료전지 시스템의 주요 작동 변수 변경에 따른 시스템 효율 민감도 분석)

  • KIM, HAN-SANG;KANG, BYUNGGIL;WON, KWONSANG
    • Journal of Hydrogen and New Energy
    • /
    • 제30권5호
    • /
    • pp.401-410
    • /
    • 2019
  • The operating conditions greatly impact the efficiency and performance of polymer electrolyte membrane (PEM) fuel cell systems and must be properly managed to ensure better performance and efficiency. In particular, small variations in operating conditions interact with each other and affect the performance and efficiency of PEM fuel cell systems. Thus, a systematic study is needed to understand how small changes in operating conditions affect the system performance and efficiency. In this paper, an automotive fuel cell system (including cell stack and balance of plant [BOP]) with a turbo-blower was modeled using MATLAB/Simulink platform and the sensitivity analyses of main operating parameters were performed using the developed system model. Effects of small variations in four main parameters (stack temperature, cathode air stoichiometry, cathode pressure, and cathode relative humidity) on the system efficiency were investigated. The results show that cathode pressure has the greatest potential impact on the sensitivity of fuel cell system efficiency. It is expected that this study can be used as a basic guidance to understand the importance of achieving accurate control of the fuel cell operating conditions for the robust operation of automotive PEM fuel cell systems.

Analysis of biological experiment on Oryeong-san (Wuling-san) (오령산 효능에 관한 기초 실험 연구 문헌 분석)

  • Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • The Journal of Internal Korean Medicine
    • /
    • 제33권1호
    • /
    • pp.69-82
    • /
    • 2012
  • Objectives : To establish objective and scientific evidence of Korean medicine (KM), the papers on Oryeong-san (Wuling-san) frequently used in medical institutions of Korean Medicine were analyzed. Methods : The papers were classified by the registration of domestic or international journals, the year of publication, experimental fields and the kinds of studies on biological activities. The therapeutic mechanism was investigated in accordance with therapeutic effect of Oryeong-san (Wuling-san). Results : Out of 57 articles selected, 16 were published in domestic journals, 17 were in Chinese journals and 24 were in Japanese journals. Most papers reported as biological activities were on improvement of renal function. Oryeong-san (Wuling-san) increased urine factor such as urine excretion and electrolyte balance while decreasing proteinuria, serum factors including creatinine, cholesterol and triglyceride. In addition, injured renal tissue was recovered normally and gene expression controlling urine excretion was down-regulated. Conclusions : Improvement of renal function could be interpreted as objective and scientific evidence for Oryeong-san (Wuling-san).