• Title/Summary/Keyword: Electrode area

Search Result 970, Processing Time 0.027 seconds

Frequency Response of the electrode for Indirect-contact ECG (간접접촉 심전도 측정용 전극의 주파수 특성)

  • Lim, Yong-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

A Groove Technique for Securing an Electrode Connector on the Cranial Bone : Case Analysis of Efficacy

  • Lee, Sung-Woo;Lee, Myung-Ki;Seo, Il;Kim, Ho-Sang;Kim, Jeong-Ho;Kim, Yun-Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.130-134
    • /
    • 2014
  • Objective : A groove technique for securing an electrode connector was described as an alternative surgical technique in deep brain stimulation (DBS) surgery to avoid electrode connector-related complications, such as skin erosion, infection, and migration. Methods : We retrospectively reviewed 109 patients undergoing one of two techniques; the standard technique (52 patients using 104 electrodes) and the groove technique (57 patients using 109 electrodes) for securing the electrode connector in DBS surgery, regardless of patient disease. In the standard percutaneous tunneling technique, the connector was placed on the vertex of the cranial surface. The other technique, so called the groove technique, created a groove (about 4 cm long, 8 mm wide) in the cranial bone at the posterior parietal area. Wound erosion and migration related to the connectors were compared between the two techniques. Results : The mean follow-up period was 73 months for the standard method and 46 months for the groove technique. Connector-related complications were observed in three patients with the groove technique and in seven patients with the standard technique. Wound erosion at the connector sites per electrode was one (0.9%) with the groove technique and six (5.8%) with the standard technique. This difference was statistically significant. The electrode connector was migrated in two patients with the groove technique and in one patient with the standard technique. Conclusions : The groove technique, which involves securing an electrode using a groove in the cranial bone at the posterior parietal area, offers an effective and safe method to avoid electrode connector-related complications during DBS surgery.

Automated external defibrillator electrode pad placement by the general public and health-care providers : A manikin study (일반인 및 의료종사자들의 자동제세동기를 이용한 제세동에서 전극부착 위치에 관한 연구: 마네킨을 이용한 연구)

  • Park, Si-Eun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.1
    • /
    • pp.83-94
    • /
    • 2016
  • Purpose: This study aimed to assess defibrillator pad positioning by the general public and healthcare providers during basic life support (BLS) renewal education (RE). Methods: A total 130 subjects performed defibrillation using an automated external defibrillator (AED) equipped with electrode pads developed by the researchers and male resuscitation manikins, in order to assess electrode pad placement (EPP) before BLS RE. Subjects included 54 Healthcare providers (HP) and 76 members of the general public (GP). Results: The apex EPP was positioned in the risk area (RA), more than 5 cm distant from the area recommended, by 63.2% of the GP (n = 48). The apex EPP was positioned in the RA by 44.4% of the HP (n = 23). The distance from the apex (GP $5.27{\pm}2.21cm$, HP $4.18{\pm}1.71cm$) was statistically significant, using Student's t-test. Conclusion: For both GP and HP, apex EPP was significantly in error. Thus, to prevent defibrillation failures, EPP education and practice for GP and HP in all BLS education programs should be improved, and incorrect Korean cardiopulmonary resuscitation guidelines and related literature should be revised and corrected.

Electrode fabrication and Performance of Single Cell with an area of $2000\;cm^2$ in PAFC ($2000\;cm^2$ 대면적 인산형 연료전지 전극 제조 및 단위전지 성능 특성)

  • Song, Rak-Hyun;Shin, Dong-Ryul;Kim, Chang-Soo;Lee, Byung-Rok;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1308-1310
    • /
    • 1997
  • Several methods for electrode fabrication of phosphoric acid fuel cell(PAFC) have been studied. The conventional methods that include a coating method and a rolling method, have disadvantages of a very complicated drying process and a hot pressing process for making a large electrode. In this study, to solve these problems, the mixing method of coating and rolling processes has been developed. In the mixing method, the electrode was coated on the electrode support and, after drying the coated layer, was rolled at room temperature and then sintered at $350^{\circ}C$. The single cell performances of the electrodes fabricated by several methods were examined and the mixing method appeared a good cell performance of 0.65 V, $260\;mA/cm^2$. Also the single cell with an area of $2000\;cm^2$ was manufactured and its performance attained 0.593 V, 300 A.

  • PDF

Development of High Performance MEA by Decal Method for PEM Fuel Cell (데칼 공정을 적용한 고성능 MEA 개발)

  • Lee, Ki-Sub;Lee, Jae-Seung;Kwon, Nak-Hyun;Hwang, In-Chul
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.5
    • /
    • pp.585-591
    • /
    • 2011
  • This study has focused on the development of high performance membrane-electrode assemblies (MEAs) fabricated by decal method for proton exchange membrane fuel cell (PEMFC). To study the effect of ionomer contents on performance, we fabricated MEAs with several electrodes which were prepared by varying the quantity of ionomer from 20 wt.% to 45 wt.% in catalyst layer. The MEA performance was obtained through single cell test. The MEA prepared from electrode with 25wt.% of ionomer showed the best performance. We evaluated the surface area and pore volume of electrode with BET. We found that the surface area and pore volume in electrode decreased rapidly at the electrode with 40wt.% of ionomer in catalyst layer. MEA was fabricated by roll laminator machine and the roll laminating conditions for the preparation of MEA, such as laminating press, temperature and speed, were optimized. The MEA performance is not affected by laminating temperature and speed, but roll laminating press have a great effect on MEA performance.

Effects of Electrolyte Concentration and Relative Cathode Electrode Area Sizes in Titania Film Formation by Micro-Arc Oxidation

  • Lee, Yong-K.;Lee, Kang-Soo
    • Corrosion Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.171-174
    • /
    • 2010
  • MAO (micro-arc oxidation) is an eco-friendly convenient and effective technology to deposit high-quality oxide coatings on the surfaces of Ti, Al, Mg and their alloys. The roles of the electrolyte concentration and relative cathode electrode area sizes in the grown oxide film during titanium MAO were investigated. The higher the concentration of the electrolyte, the lower the $R_{total}A$ value. The oxide film produced by the lower concentration of the electrolyte is thinner and less uniform than the film by the higher concentration, which is thick and porous. The cathode area size must be bigger than the anode area size in order to minimize the voltage drop across the cathode. The ratio of the cathode area size to the anode area size must be bigger than 8. Otherwise, the cathode will be another source for voltage drop, which is detrimental to and slows down the oxide growth.

Degradation Accelerated Stress Test of Electrode and Membrane in PEMFC (PEMFC에서 전극과 전해질 막의 열화 가속 시험)

  • Song, Jin-Hoon;Kim, Sae-Hoon;Ahn, Byung-Ki;Ko, Jai-Joon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.778-782
    • /
    • 2012
  • Until a recent day, degradation of PEMFC MEA (membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. Therefore in this work, AST (Accelerated Stress Test) of MEA degradation was done at the condition that membrane and electrode were degraded simultaneously. There was interaction between membrane degradation and electrode degradation. Membrane degradation reduced the decrease range of catalyst active area by electrode degradation. Electrode degradation reduces increase range of the hydrogen crossover current and FER (Fluoride Emission Rate) by membrane degradation.

Reducing of cross-talk by patterning of common electrode in the patterned vertical alignment (PVA) mode (PVA모드에서 공통 전극 패턴을 통한 전기장 간섭의 감소 효과)

  • Jeon, Yeon-Mun;Kim, Youn-Sik;Hwang, Seong-Jin;Lee, Seung-Hee;Lyu, Jae-Jin;Kim, Kyeong-Hyeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.43-44
    • /
    • 2006
  • We have studied electro-optical characteristics and stability of liquid crystal director depending on electrode patterning of common electrode on top substrate in patterned vertical alignment (PVA) mode. In the present studies, new type of common electrode pattern was suggested to enhance a dark state by reducing interference area due to data signal. According to the simulation result, PVA device with new common electrode pattern contributed to Improvement of an aperture ratio.

  • PDF

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

Fabrication of High-performance Carbon Counter Electrode for Dye-sensitized Solar Cells (염료감응 태양전지용 고성능 탄소 상대전극 제작)

  • Jang, Yeon-Ik;Lee, Seung-Yong;Kim, Dong-Hwan;Park, Jong-Ku
    • Journal of Powder Materials
    • /
    • v.14 no.1 s.60
    • /
    • pp.44-49
    • /
    • 2007
  • In the fabrication of dye-sensitized solar cells (DSSCs), carbon counter electrode has been tested for replacing the platinum counter electrode which has two drawbacks: limited surface area and high material cost. Poor mechanical stability of carbon layer due to weak bonding strength to electrically conductive TCO (transparent conducting oxide) glass substrate is a crucial barrier for practical application of carbon counter electrode. In the present study a carbon counter electrode with high conversion efficiency, comparable to Pt counter electrode, could be fabricated by adaption of a bonding layer between particulate carbon material and TCO substrate.