• 제목/요약/키워드: Electrochemical test

검색결과 736건 처리시간 0.029초

Polyoxyalkylene Glycol Acrylate기 Gel Polymer Electrolyte를 적용한 리튬이온폴리머전지의 전기화학적 특성 (Electrochemical Performances of Lithium-ion Polymer Battery with Polyoxyalkylene Glycol Acrylate-based Gel Polymer Electrolyte)

  • 김현수;김성일;나성환;문성인
    • 한국전기전자재료학회논문지
    • /
    • 제18권2호
    • /
    • pp.142-147
    • /
    • 2005
  • In this work, a gel polymer electrolyte (GPE) was prepared using polyoxyalkylene glycol acrylate (POAGA) as a macromonomer LiCoO$_2$/GPE/graphite cells were prepared and their electrochemical properties were evaluated at various current densities and temperatures. The ionic conductivity of the GPE was more than 6.2${\times}$10$^{-3}$ S$.$$cm^{-1}$ / at room temperature. The GPE had good electrochemical stability up to 4.5 V vs. Li/Li$^{+}$. POAGA-based cells were showed good electrochemical performances such as rate capability, low-temperature performance, and cycleability. The cells, also, passed a safety test such as the overcharge and nail-penetration test.t.

Cr-Mo강 시효재의 취화손상 평가를 위한 전기화학적 분극시험에 관한 연구 (A Study on Electrochemical Polarization Test for Embrittlement Damage Evaluation of Aged Cr-Mo Steel)

  • 유효선
    • 비파괴검사학회지
    • /
    • 제19권6호
    • /
    • pp.411-419
    • /
    • 1999
  • 에너지 변환설비와 관련된 기계구조물의 내열재료는 $350^{\circ}C{\sim}550^{\circ}C$의 온도범위에서 장시간 사용되는데 이때 조직의 결정입계에는 불순물 원소(P, Sn, Sb등)의 편석과 탄화물의 석출 등으로 인하여 재료의 취화 현상이 발생되고, 그로 인해 입계강도의 저하가 초래된다. 따라서 노후화된 고온설비의 안전성 및 효율적인 운전조건을 확보하고, 취성파괴 방지를 위해서는 취화손상의 정량적 평가는 매우 중요하다. 그러나 가동중인 고온설비에서 파괴시험을 위한 대량의 시험편채취가 거의 불가능한 경우가 대부분이므로 비파괴적인 시험방법이 요구된다. 본 연구에서는 인공시효열처리된 2.25Cr-1Mo강의 비파괴적인 취화손상도 평가를 위해 적정 부식환경하에서 전기화학적 분극시험 방법에 의한 최적의 평가인자를 조사하였다. 또한 전기화학 시험결과들은 준비파괴시험인 SP시험에 의한 취화도 평가결과와 비교되었다.

  • PDF

전기화학적 양극분극시험에 의한 고온 설비부재의 열화손상 평가 (Degradation Damage Evaluation of High Temperature Structural Components by Electrochemical Anodic Polarization Test)

  • 유호선;송문상;송기욱;류대영
    • 대한기계학회논문집A
    • /
    • 제24권6호
    • /
    • pp.1398-1407
    • /
    • 2000
  • The structural steels of power plant show the decrease of mechanical properties due to degradation such as temper embrittlement, creep damage and softening during long-term operation at high temper ature. The typical causes of material degradation damage are the creation and coarsening of carbides(M23C6, M6C) and the segregation of impurities(P, Sb and Sn) to grain boundary. It is also well known that material degradation induces the cleavage fracture and increases the ductile-brittle transition temperature of steels. So, it is very important to evaluate degradation damage to secure the reliable and efficient service condition and to prevent brittle failure in service. However, it would not be appropriate to sample a large test piece from in-service components. Therefore, it is necessary to develop a couple of new approaches to the non-destructive estimation technique which may be applicable to assessing the material degradation of the components with not to influence their essential strength. The purpose of this study is to propose and establish a new electrochemical technique for non-destructive evaluation of material degradation damage for Cr-Mo steels which is widely used in the high temperature structural components. And the electrochemical anodic polarization test results are compared with those of semi-nondestructive SP test.

열화평가에 전기화학적 방법의 응용에 관한 연구 (A study on the application of electrochemical method for degradation evaluation)

  • 권재도;문윤배;김상태
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.44-51
    • /
    • 1998
  • In order to develop the evaluation methods of degradation for the Ni-Cr-Mo-V steel, which is in use for turbine rotor in nuclear power plant, the degraded materials were prepared by simulated degradation methods. The result of impact test and fatigue crack growth test shows that the FATT(Fracture Appearance Transition Temperature) and fatigue crack growth rate increased with the increase of degradation. And the result of new electrochemical polarization test method was suggested for the evaluating FATT, fatigue crack growth exponent and coefficient C values based on the results of relationship between corrosion current density(Icorr) & FATT, and the m & C and Icorr.

고주파 아크 금속용사공법을 이용한 용사금속의 방식성능 평가 (Evaluation of the Corrosion Protective Property in Steel applying Spray Metal by using High-frequency Arc Metal Spray Method)

  • 최홍복;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.94-95
    • /
    • 2014
  • The purpose of this study is to evaluate the corrosion protective property of Al-Mg high-freqeuncy arc metal spray method in comparison to Zn-Sn and Zn-Al alloys by electrochemical method and CASS test. As a result, it appeared that Al-Mg alloy had very higher corrosion protective property through the electrochemical characteristic and the CASS test comparing with the other alloys.

  • PDF

Corrosion Evaluation of Epoxy-Coated Bars by Electrochemical Impedance Spectroscopy

  • Choi, Oan-Chul;Park, Young-Su;Ryu, Hyung-Yun
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.99-105
    • /
    • 2008
  • Southern exposure test specimens were used to evaluate corrosion performance of epoxy-coated reinforcing bars in chloride contaminated concrete by electrochemical impedance spectroscopy method. The test specimens with conventional bars, epoxy-coated bars and corrosion inhibitors were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. The polarization resistance obtained from the Nyquist plot was the key parameter to characterize the degree of reinforcement corrosion. The impedance spectra of specimens with epoxy-coated bars are mainly governed by the arc of the interfacial film and the resistance against the charge transfer through the coating is an order of magnitude higher than that of the reference steel bars. Test results show good performance of epoxy-coated bars, although the coatings had holes simulating partial damage, and the effectiveness of corrosion-inhibiting additives. The corrosion rate obtained from the impedance spectroscopy method is equivalent to those determined by the linear polarization method for estimating the rate of corrosion of reinforcing steel in concrete structures.

인발률에 따른 자동차 냉각 배관용 Al 합금의 부식 특성에 관한 연구 (Effect of Drawing Rate on the Corrosion Behavior of Al Alloy Tubes for Automotive Cooling System)

  • 박병준;김정구;안승호;곽동호;손현수
    • 대한금속재료학회지
    • /
    • 제46권8호
    • /
    • pp.489-494
    • /
    • 2008
  • The effect of drawing rate on the electrochemical properties of 3003 Al alloys in 5 wt.% NaCl solution was investigated by electrochemical techniques (potentiodynamic polarization test, potentiostatic polarization test, electrochemical impedance spectroscopy (EIS)) and surface analyses (OM, SEM, EDS). Four kinds of automotive pipe materials were prepared (raw material, drawing rate = 5, 10, 15%). As the drawing rate of Al alloy tube increased, the pitting corrosion resistance increased due to the enrichment of Al oxides on the surface.

Tracing Resistances of Anion Exchange Membrane Water Electrolyzer during Long-term Stability Tests

  • Niaz, Atif Khan;Lee, Woong;Yang, SeungCheol;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권3호
    • /
    • pp.358-364
    • /
    • 2021
  • In this study, an anion exchange membrane water electrolysis (AEMWE) cell was operated for ~1000 h at a voltage bias of 1.95 V. Impedance spectra were regularly measured every ~ 100 h, and changes in the ohmic and non-ohmic resistance were traced as a function of time. While there was relatively little change in the I-V curves and the total cell resistance during the long-term test, we observed various electrochemical phenomena in the cell: 1) initial activation with a decrease in both ohmic and non-ohmic resistance; 2) momentary and non-permanent bubble resistance (non-ohmic resistance) depending on the voltage bias, and 3) membrane degradation with a slight increase in the ohmic resistance. Thus, the regular test protocol used in this study provided clear insights into the performance degradation (or improvement) mechanism of AEMWE cells.

전기구리도금에 미치는 Mercapto화합물의 전기화학적 특성 (The Electrochemical Characteristics of Mercapto Compounds on the Copper Electroplating)

  • 손상기;이유용;조병원;이재봉;이태희
    • 전기화학회지
    • /
    • 제4권4호
    • /
    • pp.160-165
    • /
    • 2001
  • 황산원자를 포함하는 mercapto화합물은 도금시 전착속도를 증가시키는 첨가제로 알려져 있는데, 이 중 4가지의 mercapto 화합물을 선정하여 농도를 변화시켜가며 Hull cell test, Haring-Blum cell test, cathodic polarization, EQCM(Electrochemical Quartz Crystal Microbalance)등을 이용하여 도금특성 및 throwing power를 알아보았다. Cathode polarization 및 EQCM을 통한 구리 전착량을 알아본 결과 4가지의 mercapto 화합물 중 3-mercapto-1-propanesulfonic acid가 activator로서 가장 적당하였으며, 그 농도가 20 ppm에서 throwing power를 증가시키고, 농도 및 활성 과전압이 오직 $Cl^-$만 포함되었을 때보다 cathodic scan시 100 mV 만큼 shift되어 증착속도를 증가시킴을 알 수 있었다.

Effects of Ultrasonic Amplitude on Electrochemical Properties During Cavitation of Carbon Steel in 3.5% NaCl Solution

  • Jang, I.J.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.163-173
    • /
    • 2020
  • Cavitation corrosion in many industrial plants has recently become a serious issue. Cavitation corrosion has generally been investigated using a vibratory method based on ASTM G32 standard, and the test can be divided into direct cavitation and indirect cavitation. Cavitation corrosion test uses the vibration frequency of the horn of 20 kHz with constant peak-to-peak displacement amplitude. In this work, the peak-to-peak amplitude was controlled from 15 ㎛ to 85 ㎛, and electrochemical measurements were obtained during indirect cavitation. The relationship between cavitation corrosion rate and electrochemical properties was discussed. Corrosion steps of carbon steel at the initial stage under cavitation condition in 3.5 % NaCl can be proposed. When the cavitation strength is relatively low, corrosion of the steel is more affected by the electrochemical process than by the mechanical process; but when the cavitation strength is relatively high, corrosion of the steel is affected more by the mechanical process than by the electrochemical process. This work confirmed that the critical ultrasonic amplitude of 0.42 %C carbon steel is 53.8 ㎛, and when the amplitude is less than 53.8 ㎛, the corrosion effect during the cavitation corrosion process is higher than the mechanical effect.