• Title/Summary/Keyword: Electrochemical Determination

Search Result 199, Processing Time 0.027 seconds

Development of a Biosensor Using Electrochemically-Active Bacteria [EAB] for Measurements of BOD [Biochemical Oxygen Demand] (전기화학적 활성 미생물을 이용한 BOD 측정용 바이오센서의 개발)

  • Yoon, Seok-Min;Choi, Chang-Ho;Kwon, Kil-Koang;Jeong, Bong-Geun;Hong, Seok-Won;Choi, Yong-Su;Kim, Hyung-Joo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.438-442
    • /
    • 2007
  • A biosensor using electrochemically-active bacteria (EAB) enriched in three-electrode electrochemical cell, was developed for the determination of biochemical oxygen demand (BOD) in wastewater. In the electrochemical cell, the positively poised working electrode with applying a potential of 0.7 V was used as an electron acceptor for the EAB. The experimental results using artificial and raw wastewater showed that the current pattern generated by the biosensor and its Coulombic yield were proportional to the concentration of organic matter in wastewater. The correlation coefficients of BOD vs Coulombic yield and $BOD_5$ vs Coulombic yield were 0.99 and 0.98, respectively. These results indicate that the biosensor enriched with the EAB capable of transferring electrons directly toward the electrode can be utilized as a water-quality monitoring system due to a quick and accurate response.

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.

Amperometric Morphine Detection Using Pt-Co Alloy Nanowire Array-modified Electrode

  • Tao, Manlan;Xu, Feng;Li, Yueting;Xu, Quanqing;Chang, Yanbing;Wu, Zaisheng;Yang, Yun-Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1968-1972
    • /
    • 2010
  • Pt-Co alloy nanowire array was directly synthesized by electrochemical deposition with polycarbonate template at -1.0V and subsequent chemical etching of the template. The use of Pt-Co alloy nanowire array-modified electrode (Pt-Co NAE) for the determination of morphine (MO) is described. The morphology of the Pt-Co alloy nanowire array has been investigated by scanning electron microscopy (SEM) and energy disperse X-ray spectroscopy (EDS) analysis), respectively. The resulting Pt-Co NAE offered a linear amperometric response for morphine ranging from $2.35\times10^{-5}$ to $2.39\times10^{-3}$ M with a detection limit of $7.83\times10^{-6}$ M at optimum conditions. This sensor displayed high sensitivity and long-term stability.

Structural Studies of Copper(II)-Hippuryl-L-histidyl-L-leucine(HHL) Complex by NMR Methods

  • Lee Seong-Ran;Jun Ji-Hyun;Won Ho-Shik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.115-125
    • /
    • 2006
  • Hippuryl-L-histidyl-L-leucine(HHL) is widely used as a substrate of angiotensin converting enzyme(ACE) cleaving the neurotransmitter angiotensin(I) to the octapeptide angiotensin(II). The structure of the substrate molecules should provide information regarding the geometric requirements of the ACE active site. For the purpose of determination of in vivo reaction, metallo(Cu, Zn)-HHL complexes were synthesized and the degree of complex formation were identified by MALDITOF, ESI mass spectrometric analysis. Tn addition, the pH-dependent species distribution curves were obtained by potentiometric titration. Nitrogen atoms of imidazole ring and oxygen atom of caboxylate groups in the peptide chain were observed to be participated in the metal complex formation. After purification of complexes further structural characterization were made by utilizing UV-Vis, electrochemical methods and NMR. Complete NMR signal assignments were carried out by using 2D-spectrum techniques COSY, TOCSY, NOESY, HETCOR. A complex that two imidazole and carboxylate groups are asymmetrically participating to coordination mode was predicted to the solution-state structure of $Cu(II)-HHL_2$ based on $^{13}C-NMR$ signal assignment and NOE information.

  • PDF

Principle of Sensor Systems by using a Quartz Crystal and Their Applications (수정진동자를 이용한 센서시스템의 원리와 응용)

  • Kim, Jong-Min;Chang, Sang-Mok;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.655-668
    • /
    • 2009
  • The principle and applications of quartz crystal sensors based on the three basic concepts for mass, viscosity, and viscoelastic changes are reviewed. In the general discussion the basic principle of quartz crystal and realization of a resonant frequency-resonant resistance diagram are described in detail. As examples of their applications, gas sensing with a carbon-coated quartz crystal, determination of the blood coagulation factor, an electrochemical analysis and crystallization analysis are reported. The possibility of developing new biosensors and chemical sensors is discussed on the basis of these results.

Conductivity of PAN/PVDF based Polymer Electrolyte as a Function of Plasticizer Mixed Ratio (가소제 혼합비에 따른 PAN/PVDF계 고분자 전해질의 이온 전도 특성)

  • Lee, Jae-An;Kim, Jong-Uk;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.261-264
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio. PAN/PVDF based polymer electrolyte films were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. By adding PVDF and as a function of plasticizer mixed ratio to PAN-LiClO4 electrolyte, its conductivity was higher than that of PAN-$LiClO4_4$ electrolyte. The conductivity of PAN/PVDF electrolytes was $10^{-3}S/cm$. $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte shows the better conductivity of the others. Steady state current method and ac impedance used for the determination of transference numbers in PAN/PVDF electrolyte film. The transference number of $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte is 0.45.

  • PDF

Effect of CO in Anode Fuel on the Performance of Polymer Electrolyte Membrane Fuel Cell (수소연료 중 일산화탄소의 고분자전해질 연료전지에 대한 영향)

  • Kwon, Jun-Taek;Kim, Jun-Bum
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2008
  • Carbon monoxide(CO) is one of the contamination source in reformed hydrogen fuel with an influence on performance of polymer electrolyte membrane fuel cell(PEMFC). The studies of CO injection presented here give information about poisoning and recovery processes. The aim of this research is to investigate cell performance decline due to carbon monoxide impurity in hydrogen. Performance of PEM fuel cell was investigated using current vs. potential experiment, long time(10 hours) test, cyclic feeding test and electrochemical impedance spectra. The concentrations of carbon monoxide were changed up to 10 ppm. Performance degradation due to carbon monoxide contamination in anode fuel was observed at high concentration of carbon monoxide. The CO gas showed influence on the charge transfer reaction. The performance recovery was confirmed in long time test when pure hydrogen was provided for 1 hour after carbon monoxide had been supplied. The result of this study could be used as a basis of various reformation process design and fuel quality determination.

Ion Conduction Properties of PVDF/PAN based Polymer Electrolyte for Lithium Polymer Battery (리튬 폴리머전지용 PVDF/PAN계 고분자 전해질의 이온 전도 특성)

  • 이재안;김종욱;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.306-311
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. The temperature dependence of conductivity impedance spectroscopy and electrochemical properties of PDF/PAN electrolytes as a function of a mixed ratio were reported for PVDF/PAN based polymer electrolyte films which were prepared by thermal gellification method of preweighed PVDF/PAN plasticizer and Li salt. The conductivity of PVDF/PAN electrolytes was 10$\^$-3/S/cm. 20PVDF5PEN LiCiO$\_$4//PC$\_$10//EC$\_$10/ electrolyte has the better conductivity compared to others. 20PVDF5PANLICIO$\_$4//PC$\_$10//EC$\_$10/ electroylte remains stable up to 5V vs. Li/Li$\^$+/. Steady state current method and ac impedance were used for the determination of transference numbers in PVDF/PAN electrolyte film. The transference number of 20PVDF5PANLiCO$\^$4//PC$\_$10//EC$\_$10/ electrolyte is 0.48.

  • PDF

Electrochemical Sensor for the Selective Determination of Prindopril Based on Phosphotungestic Acid Plastic Membrane

  • Zareh, Mohsen M.;Wasel, Anower M.;Alkreem, Yasser M. Abd
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.3088-3092
    • /
    • 2013
  • A novel PVC membrane sensor for perindopril based on perindopril-phosphotungstate ion pair complex was prepared. The influence of membrane composition (i.e. percent of PVC, plasticizer, ion-pair complex, and kind of plasticizer), inner solution, pH of test solution and foreign cations on the electrode performance was investigated. The optimized membrane demonstrates Nernstian response ($30.9{\pm}1.0$ mV per decade) for perindopril cations over a wide linear range from $9.0{\times}10^{-7}$ to $1{\times}10^{-2}$ M at $25^{\circ}C$. The potentiometric response is independent of the pH in the range of 4.0-9.5. The proposed sensor has the advantages of easy preparation, fast response time. The selectivity coefficients indicate excellent selectivity for perindopril over many common cations (e.g., $Na^+$, $K^+$, $Mg^{2+}$, $Cu^{2+}$, $Ni^{2+}$, rhamnose, maltose, glycine and benzamide. The practical applications of this electrode was demonstrated by measuring the concentrations of perindopril in pure solutions and pharmaceutical preparations with satisfactory results.

Direct electrochemistry of hemoglobin at carbon electrode modified with lipid film and its application as a $H_{2}O_{2}$ sensor (Lipid Film에 수식된 헤모글로빈의 전기화학적 특성과 $H_{2}O_{2}$응답특성)

  • Lee, Dong-Yun;Park, Sang-Hyun;Choi, Yong-Sung;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.93-94
    • /
    • 2006
  • In this research, the enhancement of electron-transfer activity of hemoglobin (Hb) in dodecanoic acid film was investigated for the first time. This type of composite film was made on glassy carbon electrode by casting method. Cyclic voltammetric result of the modified electrode displays a well defined redox peaks which was attributed to the direct electrochemical response of Rb. Our results illustrate that Rb exchange electrons directly with electrode and exhibits the characteristics of peroxidase. When we apply this modified electrode as a biosensor, it gives excellent performances in the electrocatalytic reduction of hydrogen peroxide ($H_{2}O_{2}$). Through the optimal conditions, the proposed biosensor shows the linear range for H2O2 determination was from $1{\times}10^{-5}$ to $1.25{\times}10^{-4}mol/L$ with a detection limit of $1{\times}10^{-7}mol/L$. The biosensor retained more than 90% of the initial response after 14 days.

  • PDF