• 제목/요약/키워드: Electrochemical Detection

검색결과 340건 처리시간 0.026초

직병렬조합 배터리팩의 안전운용을 위한 Z-score 기반 이상 동작 검출 방법 (Z-score Based Abnormal Detection for Stable Operation of the Series/Parallel-cell Configured Battery Pack)

  • 강덕훈;이평연;김덕한;김성근;김종훈
    • 전력전자학회논문지
    • /
    • 제26권6호
    • /
    • pp.390-396
    • /
    • 2021
  • Lithium-ion batteries have been designed and used as battery packs with series and parallel combinations that are suitable for use. However, due to its internal electrochemical properties, producing the battery's condition at the same value is impossible for individual cells. In addition, the management of characteristic deviations between individual cells is essential for the safe and efficient use of batteries as aging progresses with the use of batteries. In this work, we propose a method to manage deviation properties and detect abnormal behavior in the configuration of a combined battery pack of these multiple battery cells. The proposed method can separate and detect probabilistic low-frequency information according to statistical information based on Z-score. The verification of the proposed algorithm was validated using experimental results from 10S3P battery packs, and the implemented algorithm based on Z-score was validated as a way to effectively manage multiple individual cell information.

Polyaniline을 이용한 CNT fiber 유연 전극 기반의 비효소적 글루코스 검출 (Enzyme-Free Glucose Sensing with Polyaniline-Decorated Flexible CNT Fiber Electrode)

  • 송민정
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.1-6
    • /
    • 2022
  • 최근 웨어러블 디바이스에 대한 수요가 증가하면서 유연 전극 소재 개발에 대한 다양한 연구들이 진행되고 있다. 특히, 헬스케어용 웨어러블 센서들은 체온이나 심장 박동, 혈당, 혈중 산소 농도 등 신체 정보들의 실시간·지속적인 모니터링과 정확한 진단, 검출이 가능해야 하기 때문에 고성능 유연 전극 소재의 개발이 무엇보다 중요하다. 본 연구에서는 탄소나노튜브 섬유(carbon nanotube fiber; CNT fiber) 기반의 유연 전극 소재의 성능을 개선시키기 위해 CNT fiber 위에 전기화학적 중합(electrochemical polymerization) 공정을 통해 polyaniline (PANI) layer를 합성하고, 이에 대한 전기화학적 특성 분석과 비효소적 글루코스(glucose) 검출 특성을 확인하였다. 제작된 PANI/CNT fiber 전극의 표면 분석은 주사전자 현미경(SEM)을 이용하여 진행되었으며, 전극의 전기화학적 특성 및 글루코스에 대한 센싱 성능은 시간대전류법(CA)과 순환전압 전류법(CV), 전기화학 임피던스법(EIS)을 이용하여 분석되었다. PANI/CNT fiber 전극의 전기화학적 특성은 bare CNT fiber 전극에 비해 작은 electron transfer resistance와 낮은 peak separation potential, 증가된 전극 면적을 나타내며, 이런 향상된 특성들 덕분에 글루코스 검출에 대한 센싱 성능이 개선되었다. 따라서, 본 연구를 기반으로 다양한 나노구조체를 도입하고 접목을 통해 고성능 CNT fiber 기반의 유연 전극 소재 개발이 가능할 것으로 기대된다.

Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode

  • Xu, Guang-Ri;Xu, Guifang;Xu, Ming-Lu;Zhang, Zhengqing;Tian, Yuan;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권2호
    • /
    • pp.415-419
    • /
    • 2012
  • Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range $2.0{\times}10^{-6}$ to $5.0{\times}10^{-4}$ M with the detection limit of $2.0{\times}10^{-6}$ M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Cl^-$, $HPO_4^{2-}$ and $H_2PO_4^- $. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.

Horseradish peroxidase가 변성된 탄소복합 바이오센서 개발 및 전기화학적 H2O2분석 (Development of HRP-modified Carbon Composite Biosensor and Electrochemical Analysis of H2O2)

  • 박덕수
    • 대한화학회지
    • /
    • 제56권5호
    • /
    • pp.571-576
    • /
    • 2012
  • Horseradish peroxidase (HRP), alkoxysilane인 TEOS의 겔 용액과 graphite를 혼합하여, 전기전도성을 나타내고 재사용이 가능하며 안정성을 향상시킨 carbon composite electrodes (CCEs) 바이오센서를 제작하였다. TEOS의 졸-겔 전이반응을 이용하여 HRP를 silicate gel network포획시킨 바이오센서는 -0.2 V에서 $H_2O_2$의 환원이 시작되었으며, HRP의 함량과 pH를 변화시켜 최적 분석 조건을 구하였다. 분석 최적 조건에서 검량선 및 검출한계를 구한 결과, 0.2~2.2 mM의 $H_2O_2$ 농도 범위에서 직선적인 감응을 나타내며 검출한계는 0.035 mM이었다. ascorbic acid, acetaminophene, uric acid의 방해작용을 조사한 결과 $H_2O_2$의 전기화학적 분석에 영향을 주지 않았다.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

Detection of Food-Grade Hydrogen Peroxide by HRP-Biocomposite Modified Biosensors

  • Chang, Seung-Cheol
    • 한국식품위생안전성학회지
    • /
    • 제32권6호
    • /
    • pp.447-454
    • /
    • 2017
  • 본 연구의 목적은 식품 제조 중 표백 및 살균에 사용되는 과산화수소($H_2O_2$)의 잔류 농도 검출에 활용 될 수 있는 유리탄소전극 기반의 바이오센서의 개발이다. 미국 FDA 및 국내 식품의학안전처 등 식품 용 과산화수소(food grade $H_2O_2$)는 국내외적으로 35% $H_2O_2$ 수용액으로 규정한다. 연구에서 개발한 바이오센서는 감응 물질로 사용된 horseradish peroxidase를 graphene oxide와 aniline과 함께 biocomposite를 형성시킨 후 중성 pH에서 본 연구에서 새롭게 개발된 전기화학적 증착법을 수행하여 개발되었다. 센서구조 및 특성 평가를 위하여 SEM, 순환 전압 전류법 등을 수행하였으며 본 연구에서 개발된 바이오센서는 $10-500{\mu}M$ 농도의 $H_2O_2$에 대하여 직선상의 농도 의존적인 반응을 나타내었으며 최저 검출 한계는 $0.12{\mu}M$으로 산출되었다. 본 연구에서 개발된 센서의 전략적 가치는 향후 오징어포, 건어물 등 널리 유통되는 식품 중에 함유된 식품용 $H_2O_2$ 미량을 현장에서 쉽게 분석 할 수 있어서 비용-효과적 측면에서 그 가치가 우수하다는 것을 제시한다.

Electrochemical Gene Detection Using Microelectrode Array on a DNA Chip

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.145-148
    • /
    • 2004
  • In this study, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5' end were immobilized on the gold electrodes by a DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 and concentrated at the electrode surface through association with the formed hybrid. This suggested that this DNA chip could recognize the sequence specific genes.

미소전극어에이형 DNA칩을 이용한 유전자의 전기화학적 검출 (Electrochemical Detection of Genes Using Microeledtrode Array DNA Chip)

  • 최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2125-2127
    • /
    • 2004
  • In this paper, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5 end were immobilized on the gold electrodes by DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 concentrated at the electrode surface through association with formed hybrid. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

A Novel Sensor Based on Electropolymerization Poly(safranine) Film Electrode for Voltammetric Determination of 4-Nitrophenol

  • Liu, Xing-Yuan
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1182-1186
    • /
    • 2010
  • A novel poly(safranine)-modified electrode has been constructed for the determination of 4-nitrophenol (4-NP) in natural water sample. The electrochemical behavior of poly(safranine) film electrode and its electrocatalytic activity toward 4-NP were studied in detail by cyclic voltammetry (CV) and adsorptive linear stripping voltammetry (LSV). All experimental parameters were optimized and LSV was proposed for its determination. In optimal working conditions, the reduction current of 4-NP at this poly(safranine)-modified electrode exhibited a good linear relationship with 4-NP concentration in the range of $8.0{\times}10^{-8}$ to $4.0{\times}10^{-5}mol\;L^{-1}$. The detection limit was $3.0{\times}10^{-8}mol\;L^{-1}$. The high sensitivity and selectivity of the sensor were demonstrated by its practical application for the determination of trace amounts of 4-NP in natural water and fruit samples.

A Study on Gene Detection using Non-labeling DNA

  • Choi Yong-Sung;Lee Kyung-Sup;Kwon Young-Soo
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.960-965
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip using microfabrication technology. At first, we fabricated a high integration type DNA chip array by lithography technology. Several probe DNAs consisting of thiol group at their 5-end were immobilized on the gold electrodes. Then target DNAs were hybridized and reacted. Cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. Therefore, it is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes.