• 제목/요약/키워드: Electroanalysis

검색결과 8건 처리시간 0.019초

Electrochemical Determination of 6-Benzylaminopurine (6-BAP) Using a Single-wall Carbon Nanotube-dicetyl Phosphate Film Coated Glassy Carbon Electrode

  • Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권7호
    • /
    • pp.991-994
    • /
    • 2006
  • Herein, insoluble single-walled carbon nanotube (SWNT) was successfully dispersed into water in the presence of a special kind of surfactant-dicetyl phosphate (DCP), subsequently, a SWNT-DCP composite film coated glassy carbon electrode (GCE) was fabricated. The electrochemical behaviors of 6-benzylaminopurine (6-BAP) at the unmodified GCE and SWNT-DCP modified GCE were examined. It is found that the SWNT-DCP modified GCE remarkably enhances the oxidation peak current of 6-BAP, indicating great potential in the determination of trace level of 6-BAP. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of ${\times}5.0\;\;10^{-8}\sim 2.5\;{\times}\;10^{-6}$ mol/L, was developed for the determination of 6-BAP. The detection limit is as low as $2.0\;{\times}\;10^{-8}$ mol/L for 3-min accumulation. This newly-proposed method was successfully demonstrated with practical samples.

Studies on Enhanced Oxidation of Estrone and Its Voltammetric Determination at Carbon Paste Electrode in the Presence of Cetyltrimethylammonium Bromide

  • Yang, Chunhai;Xie, Pingping
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권10호
    • /
    • pp.1729-1734
    • /
    • 2007
  • The electrochemical behaviors of estrone in the presence of various surfactants were examined with great details. It is found that a cationic surfactant, cetyltrimethylammonium bromide (CTAB), obviously facilitates the electro-oxidation of estrone at carbon paste electrode (CPE) from the significant peak current enhancement and the negative shift of peak potential. Additionally, chronocoulometry and electrochemical impedance spectroscopy (EIS) were also used for further investigation of the electrode process of estrone, indicating that low concentration of CTAB exhibits excellent enhancement effects on the electrochemical oxidation of estrone, greatly enhances the diffusion coefficient and the electron transfer rate. Based on this, an electrochemical method was proposed for the determination of estrone. The oxidation peak current is proportional to the concentration of estrone in the ranges over 9.0 × 10?8 - 8.0 × 10?6 mol/L, and a low detection limit of 4.0 × 10?8 mol/L was obtained for 180s accumulation at open circuit (S/N = 3). Finally, this proposed method was demonstrated using estrone tablets with good satisfaction.

Enhancement of Calcium-Binding Quality of Proglycinin Peptides by Chemical Phosphorylation

  • Yang, Jung-Ik;Lee, Shin-Hee;Hahm, Dae-Hyun;Kim, Il-Hwan;Choi, Sang-Yun
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.607-611
    • /
    • 2004
  • Glycinin, one of the predominant storage proteins in soybeans, was examined as to whether it could be used as a calcium-binding mediator after chemical phosphorylation and enzymatic hydrolysis. Glycinin is composed of six subunits. One of the proglycinin subunits $(A_{la}B_{lb})$ was overexpressed in E. coli to obtain nonphosphorylated proteins with homogeneity. To investigate the enhanced calcium-binding properties of the phosphopeptides, the proglycinin was purified, phosphorylated, and hydrolyzed with trypsin. The proglycinin expressed in E. coli was purified by ammonium sulfate precipitation, ion-exchange chromatography, and cryoprecipitation. Chemical phosphorylation by sodium trimetaphosphate was performed to obtain phosphorylated proglycinin. After the phosphorylation, one-dimensional isoelectric focusing gel electroanalysis confirmed the phosphorylation of the proglycinin. The phosphorylated peptides were then hydrolyzed with trypsin, followed by a binding reaction with calcium chloride. The calcium-bound phosphopeptides were finally separated using immobilized metal $(Ca^{2+})$ chromatography. Consequently, a limited tryptic hydrolysate of the isolated phosphopeptides exhibited an enhanced calcium-binding ability, suggesting the potential of glycinin phosphopeptides as a calcium-binding mediator with greater availability.

Detection of Sequence-Specific Gene by Multi-Channel Electrochemical DNA Chips

  • Zhang, Xuzhi;Ji, Xinming;Cui, Zhengguo;Yang, Bing;Huang, Jie
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.69-75
    • /
    • 2012
  • Five-channel electrochemical chips were fabricated based on the Micro-electromechanical System (MEMS) technology and were used as platforms to develop DNA arrays. Different kinds of thiolated DNA strands, whose sequences were related to white spot syndrome virus (WSSV) gene, were separately immobilized onto different working electrodes to fabricate a combinatorial biosensor system. As a result, different kinds of target DNA could be analyzed on one chip via a simultaneous recognition process using potassium ferricyanide as an indicator. To perform quantitative target DNA detection, a limit of 70 nM (S/N=3) was found in the presence of 600 nM coexisting noncomplementary ssDNA. The real samples of loop-mediated isothermal amplification (LAMP) products were detected by the proposed method with satisfactory result, suggesting that the multichannel chips had the potential for a high effective microdevice to recognize specific gene sequence for pointof-care applications.

Simultaneous Electroanalysis of Nitric Oxide and Nitrite

  • Oritani, Tadato;Okajima, Takeyoshi;Kitamura, Fusao;Ohsaka, Takeo
    • 전기화학회지
    • /
    • 제5권4호
    • /
    • pp.209-211
    • /
    • 2002
  • The simultaneous sensing of nitric oxide (NO) and its metabolite, nitrite $(NO_2^-)$ has been studied by Osteryoung square-wave voltarnmetery (OSWV) in physiological pH solution (0.1 M phosphate buffer solution, pH 7.2). Using an electrochemically pretreated glassy carbon (GC) electrode, OSWV was successfully applied to observe the well-separated oxidation peaks at ca. 0.58 and 0.80V vs. Ag/AgCI for NO and $(NO_2^-)$, respectively. This clear separation between the NO and $(NO_2^-)$ oxidation peaks may be due to the formation of surface oxides (e.g., quinone (C=O) or carboxylic $(COO^-)$ group) and surface defects introduced by the electrochemical pretreatment of GC electrodes.

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

Electrochemistry of Gallium

  • Chung, Yonghwa;Lee, Chi-Woo
    • Journal of Electrochemical Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-18
    • /
    • 2013
  • Gallium is an important element in the production of a variety of compound semiconductors for optoelectronic devices. Gallium has a low melting point and is easily oxidized to give oxides of different compositions that depend on the conditions of solutions containing Ga. Gallium electrode reaction is highly irreversible in acidic media at the dropping mercury electrode. The passive film on a gallium surface is formed during anodic oxidation of gallium metal in alkaline media. Besides, some results in published reports have not been consistent and reproducible. An increase in the demand of intermetallic compounds and semiconductors containing gallium gives rise to studies on electrosynthesis of them and an increase of gallium concentration in the environment with various application of gallium causes the development of electroanalysis tools of Ga. It is required to understand the electrochemistry of Ga and to predict the electrochemical behavior of Ga to meet these needs. Any review papers related to the electrochemistry of gallium have not been published since 1978, when the review on the subject was published by Popova et al. In this study, the redox behavior, anodic oxidation, and electrodeposition of gallium, and trace determination of gallium by stripping voltammetries will be reviewed.

Analysis of Cu in Mezcal Commercial Samples using Square Wave Anodic Stripping Voltammetry

  • Salinas, Gerardo;Ibanez, Jorge G.;Vasquez-Medrano, Ruben;Frontana-Uribe, Bernardo A.
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.276-281
    • /
    • 2018
  • High concentration of copper in mezcal, a representative Mexican spirituous alcoholic beverage, is a serious problem due to the damage that it may cause to human health. A cyclic voltammetry and square wave anodic stripping voltammetry study of copper (II) in three commercial mezcal samples based on glassy carbon electrode response was undertaken. The analysis was developed using a simulated matrix solution ($EtOH/H_2O$ (1:1), 0.1 M $LiClO_4$ and AcOH/AcONa 0.05 M/0.008 M), with Cu (II) concentrations in the range 0 - 1 ppm. Direct electrochemical analysis of mezcal samples was complicated by the presence of different organic compounds in the matrix. The analytical signal of Cu (II) in the spirituous was notably improved and the interferences caused by organic compounds were minimized, by diluting the mezcal samples 10% with $EtOH/H_2O$ (1:1) solution. An efficient quantification of Cu (II) was obtained from the calibration curve by the SWASV and using the internal standard method (Cd (II)) in commercial samples (1.2-6.7 ppm); the results were correlated satisfactorily with the values obtained by AAS.