• Title/Summary/Keyword: Electricity load

Search Result 515, Processing Time 0.267 seconds

Model Development of Daily and Hourly Energy Load for Department Stores

  • Park Hwa-Choon;Lee Sung-Soo;Kim Dae-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.169-175
    • /
    • 2004
  • Case study was performed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 depart­ments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores showed various trends depending on when they were opened or closed, or by hour, day and month. In this paper, the measurement was compared with the data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

Development of Short-Term Load Forecasting Method by Analysis of Load Characteristics during Chuseok Holiday (추석 연휴 전력수요 특성 분석을 통한 단기전력 수요예측 기법 개발)

  • Kwon, Oh-Sung;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2215-2220
    • /
    • 2011
  • The accurate short-term load forecasting is essential for the efficient power system operation and the system marginal price decision of the electricity market. So far, errors of load forecasting for Chuseok Holiday are very big compared with forecasting errors for the other special days. In order to improve the accuracy of load forecasting for Chuseok Holiday, selection of input data, the daily normalized load patterns and load forecasting model are investigated. The efficient data selection and daily normalized load pattern based on fuzzy linear regression model is proposed. The proposed load forecasting method for Chuseok Holiday is tested in recent 5 years from 2006 to 2010, and improved the accuracy of the load forecasting compared with the former research.

A Demand-side Valuation and Application of Office lighting Dimming Control in Electricity Markets (사무소 건물의 조광제어를 통한 수요관리자원 발굴 및 전력시장에서의 활용방안에 관한 연구)

  • Kim, Jin-Ho;Kim, Seong-Cheol;Park, Jong-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.35-41
    • /
    • 2008
  • In this paper, the new demand-side evaluation of the technical potential of lighting dimming control and its applications in electricity markets have been presented. Currently, advanced power information technologies(IT) has been developed and the variations of power information technologies have widely provided the new research and business opportunities. In particular, the dimming control for the lighting devices with time-varying prices and advanced controls has its economically significant values in electricity markets. Therefore, in this paper, the authors have explored the usefulness of lighting dimming control in load management fields as well as energy efficiency fields under the changing competitive electricity market environments.

A Study on the Participation of Virtual Power Plant Based Technology Utilizing Distributed Generation Resources in Electricity Market (분산발전자원을 활용한 가상발전소 기반 기술의 전력시장 참여 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • A virtual power plant (VPP) technology is a cluster of distributed generation installations. VPP system is that integrates several types of distributed generation sources, so as to give a reliable overall power supply. Virtual power plant systems play a key role in the smart grids concept and the move towards alternative sources of energy. They ensure improved integration of the renewable energy generation into the grids and the electricity market. VPPs not only deal with the supply side, but also help manage demand and ensure reliability of grid functions through demand response (DR) and other load shifting approaches in real time. In this paper, utilizing a variety of distributed generation resources(such as emergency generator, commercial generator, energy storage device), activation scheme of the virtual power plant technology. In addition, through the analysis of the domestic electricity market, it describes a scheme that can be a virtual power plant to participate in electricity market. It attempts to derive the policy support recommendation in order to obtain the basics to the prepared in position of power generation companies for the commercialization of virtual power plant.

An Analysis of Electricity Consumption Profile based on Measurement Data in Apartment Complex in Daejeon (대전지역 공동주택의 전력소비 실태 및 패턴 분석 연구)

  • Kim, Kang Sik;Im, Kyung Up;Yoon, Jong Ho;Shin, U Cheul
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study is to analysis the characteristics of electric power consumption of apartments complex in Korea. This study shows the pattern of electric power consumption and correlation of each apartment complex's completion year monthly and timely. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. It is expected this data is used as reference of electric consumption of Daejeon area to operate the simulation tools to predict the building energy. The yearly data of 10 apartment complexes of 2010 are analyzed. The results of this study are followed. The averaged amount of electricity consumption in winter is higher as summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 310.2kWh. A week is seperated, as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.426kWh. The Saturday consumption is 0.437kWh. The Sunday is 0.445kWh. The peak electricity consumption in summer and winter is measured. The peak consumption on summer season is 1.389kW on 22th August 64% higher than winter season 0.887kW on 3rd January.

Public Preferences for Replacing Hydro-Electricity Generation with Coal-Fired Power Generation (석탄화력 발전 대비 수력 발전에 대한 국민 선호도 분석)

  • Choi, Hyo-Yeon;Ryu, Mun-Hyun;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.164-171
    • /
    • 2015
  • Although coal-fired power generation has played a role as base load unit, it has incurred various social costs in the process of generating and providing electricity. It is necessary to extend the proportion of low-carbon power generations, and reduce the ratio of coal-fired power generation to cope with global climate changes. This study, therefore, attempts to estimate the public's willingness-to-pay (WTP) for substitution of supplied electricity from hydro-electricity generation, a representative renewable energy, for coal-fired power generation. To this end, we apply the contingent valuation (CV) method, widely used technique when valuing non-market goods, to elicit the public's WTP. In addition, a spike model is employed to consider zero WTPs. After the empirical analysis with 1,000 households CV survey data, the results show that mean household's WTP for replacing supplied electricity from hydro-electricity generation with coal-fired power generation is estimated to be about 54 KRW per kWh. The results of this study are expected to contribute to determining energy-mix and provide benefit information of hydro-electricity generation.

A Study on Development of Remote Management Controller for Intelligent Power Equipment (지능형 전원설비의 원격관리제어기 개발에 관한 연구)

  • Lim, Byung-Kuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2006
  • In this study, we research and develope Intelligent Remote management controller. According to the load condition, we will apply various control techniques and plan high efficient Demand control. After development, According to the Demand Control, An electricity enterprisers will expect enlargement of equipment coefficient, elevation of back up load factor and reduction effect of equipment investment. On Customer side, They will expect reduction of electric fee, saving energy and variety of service choice.

  • PDF

The Development of Intelligent Direct Load Control System

  • Choi, Sang Yule
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2015
  • The electric utility has the responsibility of reducing the impact of peaks on electricity demand and related costs. Therefore, they have introduced Direct Load Control System (DLCS) to automate the external control of shedding customer load that it controls. Since the number of customer load participating in the DLC program are keep increasing, DLCS operators a re facing difficulty in monitoring and controlling customer load. The existing DLCS needs constant operator intervention, e.g., whenever the load is about to exceed a predefined amount, it needs operator's intervention to control the on/off status of the load. Therefore, DLCS operators need the state-of-the-art DLCS, which can control automatically the on/off status of the customer load without intervention as much as possible. This paper presents an intelligent DLCS using the active database. The proposed DLCS is applying the active database to DLCS which can avoid operator's intervention as much as possible. To demonstrate the validity of the proposed system, variable production rules and intelligent demand controller are presented.

The Suggested Methods for Electric Load Flattening (전력(電力) 부하평준화(負荷平準化) 방안(方案))

  • Jo, Gyu-Seung;Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1985.07a
    • /
    • pp.144-147
    • /
    • 1985
  • In electricity industry, the improvement of load factor by flattening of load has been considered to be more important than any other tasks and has received wide concern and interest. Especially while annual peak load had occured early evening in winter during past decades, but we found the trend has changed so that annual peak load occured during the daytime in summer since1981 The useful practicing methods of this load management ale as follows; 1. Inducing of midnight load by thermal storage water heating 2. Seasonal differential rates. 3. Revising the peak load priceing (Time-of -use) It seems hard to expect that load research can be carried out in a short time, and we all have to exert outselves continuously to provide efficient load management method without wasting resources.

  • PDF

Emerging Subspace Discovery from Daily Load Consumption Data (전력 소비 데이터로부터의 출현 부분패턴 추출)

  • Park, Hyun Woo;Piao, Minghao;Ryu, Keun Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.908-910
    • /
    • 2013
  • Customers of different electricity consumer types have different daily load shapes in the manner of different characteristics. Therefore, maximally capture load shape variability are desirable in load flow analysis. And most of time, such load shape variability can be found in the particular subspace of load diagrams. Therefore, in this paper, we are using subspace projection method to capture the emerging subspaces of load diagrams which maximize the difference between particular load shapes in different group of customers. As the result, subspace projection method can be used in load profiling and the performance is good as traditional approaches.