• 제목/요약/키워드: Electricity consumptions

검색결과 23건 처리시간 0.023초

국가 건물에너지 통합DB 기반 건물부문 온실가스 배출현황 (Greenhouse Gas Emissions from Building Sector based on National Building Energy Database)

  • 지창윤;최민석;권오인;정하림;신성은
    • 대한건축학회논문집:구조계
    • /
    • 제36권4호
    • /
    • pp.143-152
    • /
    • 2020
  • This study analyzes in detail greenhouse gas emissions in building sector. To this end, this study used data on building characteristics (including building type, region, and construction year) and monthly energy consumptions (including electricity, city gas, and district heat) for all buildings from 2015 to 2018. These data were collected from the National Building Energy Database and the energy consumptions were converted into greenhouse gas (GHG) emissions. The total amount of GHG emissions from the building sector has increased steadily from 2015 (118.1MtCO2eq.) to 2018 (132.6MtCO2eq.). On the other hand, the more recently constructed buildings had lower GHG intensities. This result shows that strengthening building design criteria was effective on the reduction of GHG emissions in buildings, and that the increased buildings contributed to increasing GHG emissions of the building sector. In addition, sales facilities are thought to have the largest reduction potential as they had the highest amount of GHG emissions and GHG intensity. This study is expected to help establish new policies for GHG reduction in building sector as well as to evaluate the effects of existing policies.

소규모 전력 소비자 대상 수요자원 거래시장의 필요성 및 시범운영 결과 분석 (Role of Demand Response in Small Power Consumer Market and a Pilot Study)

  • 이은정;이경은;이혜수;이효섭;김은철;이원종
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.915-922
    • /
    • 2017
  • 최근 지속적인 전력 수요 증가와 이에 따른 사회적 비용 및 갈등 해결을 위한 방안으로 수요자원 거래시장(Demand Response Market)의 활성화가 크게 대두되고 있다. 국내의 경우 2014년부터 수요자원 거래시장을 운영 중이나 대규모 수요자원 거래에 집중하고 있다. 하지만, 전력 소비 비중의 증가, 큰 감축 유동성, 항상 활용 가능, 사회 인식 개선 등의 면에서 소규모 전력 소비자의 시장 참여는 성공적인 수요자원 거래시장 운영의 핵심적 요소로 볼 수 있다. 이 논문은 2016년 여름 스마트폰 어플리케이션을 활용하여 5,000명 이상의 소규모 전력 소비자를 대상으로 한 인센티브 기반(incentive-based) 수요반응(Demand Response) 프로그램의 실제 시범운영 결과를 분석하고 그 효과를 검증하며, 이를 통하여 소규모 전력 소비자 대상 수요자원 거래시장의 가능성을 제시한다.

주거건축에서 탄소를 줄이기 위한 에너지 절감 요소에 관한 연구 (To reduce carbon from residential architecture Research on energy-saving elements)

  • 박재희
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.47-52
    • /
    • 2009
  • Currently, the environmental issue is of great urgency and sensitivity to the future of our planet. Global warming caused by increased CO2 concentration has an alarming impact on the earth's fragile environment. Droughts throughout the world are causing crop failures. Wildfires now burn with far greater rage. Melting ice caps and glaciers are causing floods. Sea levels are rising. Warm unseasonable winters are threatening our fragile eco-systems. Global warming is no longer a theory; it is an obvious fact we are confronted with every day, and the only way we can prevent it is to take action now. The need to reduce CO2 emissions and try to become carbon neutral is of national importance and leadership. We have become so reliant on fossil fuels that nearly everything we do generates CO2 emissions; from our modern farming practices to transport, to the electricity used to turn on a light, boil water in a kettle or cook our meals. A reduction of 50% of CO2 emissions can easily be achieved by decreasing the energy amount used. We tracked the carbon footprint throughout the electricity and heating energy use in homes and confirmed the amount of carbon emissions according to its consumptions. In order to reduce the carbon generation from housing constructions, such as Passive House concept of buildings or low energy buildings, we must adjust its applications best fit to our conditions. And technical elements should be applied to improve our conditions, and the methodology should be actively sought. Most of all, each individual's recongnition who uses these elements is more important than any other solutions.

사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성 (Characteristics of Energy Consumption in an Office Building located in Seoul)

  • 박병윤;정광섭
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

뱀장어 양식장에서 발생하는 온실가스 배출량 산정 (Estimation of Green-House-Gas emissions from domestic eel farm)

  • 김종현;이경훈;이동길;박성욱;양용수
    • 수산해양기술연구
    • /
    • 제50권1호
    • /
    • pp.58-66
    • /
    • 2014
  • The purpose of the study is to estimate the Green-House-Gas (GHG) emissions from domestic eel farm in the water recirculation system or still-water system by the assessment of energy consumptions and GHG emissions for establishing to reduce standards of GHG from a sustainable perspective. GHG emission components as seeds, feed, fuel, electricity, fixed capital, fish respiration, and others were analysed at the different culture type between water recirculation system and still-water system by 3 stage farm size of small, medium, large scale. The result showed that the mean GHG emission of the eel farm was $18.7kg{\cdot}CO_2$ in the stage of production per fish 1kg at different culture type and farm size. Therefore it could be useful for policy, planning, and regulation of aquaculture development with establishing GHG reduction standards.

넙치 양식장에서 발생하는 온실가스 배출량 산정 (Estimation of Green-House-Gas emissions from domestic aquaculture farm for flounders)

  • 양용수;임한규;이경훈;이동길;신형호
    • 수산해양기술연구
    • /
    • 제51권4호
    • /
    • pp.614-623
    • /
    • 2015
  • This study aims to estimate the Green-House-Gas emissions from domestic farmed flounder in the southern sea and Jeju-Do, where is mainly produced, by the assessment of energy consumptions and GHG emissions from domestic fish farms for establishing reduce standards of greenhouse gas from a sustainable perspective. It needs to analyze such GHG emission components as feed, electricity, fuel, fixed capital, fish respiration, and liquid oxygen in two locations by 4 stage running water type farm size of small, small and medium, large and medium, large scale. The result showed that the mean GHG emissions were $36.83kg{\cdot}CO_2/year$ in the southern sea and $24.33kg{\cdot}CO_2/year$ in Jeju-Do, respectively, in the stage of production per fish 1kg at 2 locations and farm size from domestic farmed flounders, and it will give to be useful for policy, planning, and regulation of aquaculture development with establishing GHG reduction standards.

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

Life Cycle Impacts of Flexible-fiber Deep-bed Filter Compared to Sand-Filter including Coagulation and Sedimentation in Water Treatment Plant

  • Uh, Soo-Gap;Kim, Ji-Won;Han, Ki-Back;Kim, Chang-Won
    • Environmental Engineering Research
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2008
  • Recently a new technology called the flexible-fiber deep-bed filter (FDF) claimed to replace the conventional sand filter including coagulation and sedimentation filter (CSF) processes in the water treatment plant. Therefore the life cycle assessment (LCA) approach was applied for evaluating the life cycle impacts of FDF compared with those of CSF. The used LCA softwares were the Simapro 6 and PASS and their life cycle impact assessment (LCIA) methodologies were the Eco-indicator 99 and the Korean Eco-indicator, respectively. The goal of this LCA was to identify environmental loads of CSF and FDF from raw material to disposal stages. The scopes of the systems have been determined based on the experiences of existing CSF and FDF. The function was to remove suspended solids by filtration and the functional unit was $1\;m^3$/day. Both systems showed that most environmental impacts were occurred during the operation stage. To reduce the environmental impacts the coagulants and electricity consumptions need to be cut down. If the CSF was replaced with the FDF, the environmental impacts would be reduced in most of the impact categories. The LCA results of Korean Eco-indicator and Eco- indicator99 were quite different from each other due to the indwelling differences such as category indicators, impact categories, characterization factors, normalization values and weighting factors. This study showed that the life cycle assessment could be a valuable tool for evaluating the environmental impact of the new technology which was introduced in water treatment process.

배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가 (Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities)

  • 이재호;윤여범;현인탁;이광호
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 - (A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea)

  • 황광일
    • 한국항해항만학회지
    • /
    • 제33권3호
    • /
    • pp.241-245
    • /
    • 2009
  • 도심지의 열섬(Heat Island)현상과 연안지역의 해풍(海風)의 영향 때문에, 부산, 인천, 목포 등 연안도시의 도심지역과 연안지역의 각 외기 상태가 서로 다르게 나타난다. 이러한 외기조건은 건물의 냉방부하, 난방부하, 전력소비량 등에 직접적인 영향을 미치기 때문에, 에너지절약을 위한 건물설계와 운전방법개발을 위해서는 각 지역에 위치한 건물의 에너지소비특성을 파악해야만 한다. 본 연구에서는 연안지역 아파트의 전력소비량에 주목하였고, 부산광역시 영도구에 위치한 세대수가 100세대 이상인 22개 아파트 단지를 대상으로 기간별, 기능별 전력소비량을 조사하였다. 22개 아파트 전체의 세대내 최대전력소비량은 8월에 발생하고 있으나, 공용 최대전력소비량은 1월에 발생하고 있음을 알수 있었다. 한편 연안지역에서는 여름철에 해풍에 의한 자연환기로 인해 냉방용 전력소비가 감소할 것으로 예상하였으나, 조사결과에서는 여름철에 최대부하가 발생하였는데, 이는 해풍에 포함된 염분의 피해를 예방하기 위해 창문을 닫고 전기구동 에어컨으로 냉방하기 때문인 것으로 파악되었다.