• Title/Summary/Keyword: Electricity Supply

Search Result 650, Processing Time 0.023 seconds

Biomass Energy in the USA: A Literature Review (II) - Marketing and Policies for Green Power Production with Environmental Attributes - (미국 에너지 시장에 공급되는 바이오에너지에 관한 연구(II) - 환경친화적 녹색전기의 마케팅 및 정부지원책에 대하여 -)

  • Kim, Yeong-Suk;Gorman, Thomas
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.97-110
    • /
    • 2005
  • This paper is the second part of a literature review describing the current status of biomass energy use in the USA. The bioenergy technologies that convert biomass resources to a form of energy were presented, in particular focused on existing coal fired boiler, high efficiency gasification combined cycle. We presented latest biomass power energy supply, economic issues such as its production and plant investment cost in the Part I. In the Part II, our review summarized policy and market issues for electricity consumers, benefits from biomass power which could offer an alternative to conventional energy sources in the form of environmental, rural economic growth, and national energy security in the USA.

Installing Ozone Bleaching and Hot Acid Treatment at NPI Mills

  • Uno, Shunichiro;limori, Takeshi
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.325-329
    • /
    • 2006
  • Nippon Paper Industries, Co., Ltd. declared conversion of all the bleaching process to ECF, and most of the production had converted by now. To reduce ECF bleaching cost, we found that depending on electricity supply condition of the mill, utilization of ozone bleaching could be very effective. In addition, hot acid treatment of unbleached pulp also seemed to be effective for hardwood. In this study, several conditions for each technology were examined with the pulps from our own mills to reduce bleaching cost and to keep fiber quality acceptable level. In hot acid treatment study, with mild conditions (temperature lower than $90^{\circ}C$), sufficient reduction in Kappa number and hexenuronic acids content of the pulp were observed, while pulp viscosity was maintained. Moreover, to maintain strength of bleached pulp that subjected both to ozone bleaching and hot acid treatment, recommended Kappa number after ozone bleaching was more than 3. Based on these findings, two of our mills had installed medium-consistency ozone bleaching facilities and three mills installed hot acid treatment. Especially in Yatsushiro mill, both were installed in one bleaching line (A-ZD-E/P-D sequence), and running successfully.

  • PDF

A Study of Air-source Heat Pump Performance Analysis for Replacing Night Time Electric Heating Boiler (심야전기보일러 대체용 공기열 히트펌프 성능평가)

  • Jo, J.Y.;Jung, H;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2011
  • The night time electric cost is cheaper due to electric supply and demand policy in Korea from 1985. Currently about 900,000 customers are using night time electric heating boilers and this causes shift of peak demand time to night in winter and increase of deficit spending. To solve this problem, replacing night time electric heating boiler by air-source heat pump using night time electricity has been proposed. An air-source heat pump can provide efficient heating equipment especially in a warm climate. For estimating the night time electric heat pump COP(Coefficient of Performance), Korean Standard KS C 9306:2010 and European Standard EN-14511:2004 is available. SCOP(Seasonal COP) using European weather bin data is also calculated. SCOP is not available yet but European Committee for Standardization will establish a standard in the near future. The evaluation result show that the replacing night time electric heating boiler by heat pump can be possible.

An Operation Strategy of Udo Island Power System with the Introducing ESS (ESS 도입에 의한 우도 전력계통 운영방안)

  • LEE, DOHEON;Kim, Eel-Hwan;Kim, Ho Min;Oh, Sung-Bo;LEE, SEUNGMIN
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.57-63
    • /
    • 2015
  • This paper presents a solution by introducing energy storage system(ESS) to solve an annual blackout due to a typhoon or electrical failure in Udo Island. This island is now receiving electrical power through undersea cables from the Jeju Island. During blackout period, ESS will supply the electricity. And it is necessary to estimate the ESS capacity and control the transient state for the operation of stable power system. For the verification of proposed method, ESS capacities have been estimated according to base load and the minimum capacity of only home appliance in Udo Island. Also, in case of restoring from the fault, the algorithm for synchronization is proposed. Finally, the simulation results by using the PSCAD/EMTDC program will show the feasibility.

Problem Solving about Practical Engineering Education based on Analysis on Optimized Internal Flow of LTP Furnace and Uniformity of Temperature (LTP 퍼니스의 내부 유동 및 온도 균일도 최적화를 위한 실천공학교육적 문제해결)

  • Kim, Jin-woo;Youn, Gi-man;Jo, Eunjeong
    • Journal of Practical Engineering Education
    • /
    • v.10 no.2
    • /
    • pp.125-129
    • /
    • 2018
  • This paper is about the numerical analysis on optimized internal flow of LTP furnace and uniformity of temperature. The LTP Furnace is the device that generates heat by electricity. And performs an annealing function for annealing the silicon wafer in the pre-semiconductor manufacturing process. Especially, the maximum temperature inside the chamber is maintained at a high temperature of about $400^{\circ}C$ to strengthen the wafer. When the process is completed at high temperature, the operation is repeated to reduce the temperature through the heat exchanger and carry it out. From this analysis, the ultimate goal is to derive the optimum design of the insulation volume supply/exhaust structure of the chamber through the flow analysis of the LTPS furnace. And to find cases for curriculum development.

Calculation of Photovoltaic, ESS Optimal Capacity and Its Economic Effect Analysis by Considering University Building Power Consumption (대학건물의 전력소비패턴 분석을 통한 태양광, ESS 적정용량 산정 및 경제적 효과 분석)

  • Lee, Hye-Jin;Choi, Jeong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.5
    • /
    • pp.207-217
    • /
    • 2018
  • Recently, the importance of energy demand management, particularly peak load control, has been increasing due to the policy changes of the Second Energy Basic Plan. Even though the installation of distributed generation systems such as Photovoltaic and energy storage systems (ESS) are encouraged, high initial installation costs make it difficult to expand their supply. In this study, the power consumption of a university building was measured in real time and the measured power consumption data was used to calculate the optimal installation capacity of the Photovoltaic and ESS, respectively. In order to calculate the optimal capacity, it is necessary to analyze the operation methods of the Photovoltaic and ESS while considering the KEPCO electricity billing system, power consumption patterns of the building, installation costs of the Photovoltaic and ESS, estimated savings on electric charges, and life time. In this study, the power consumption of the university building with a daily power consumption of approximately 200kWh and a peak power of approximately 20kW was measured per minute. An economic analysis conducted using these measured data showed that the optimal capacity was approximately 30kW for Photovoltaic and approximately 7kWh for ESS.

Energy Transition and Roles of Local Governments: Renewable Energy Policy under the Moon Jae-in Administration (에너지전환과 지방정부의 역할: 문재인 정부의 재생에너지 정책을 중심으로)

  • Han, Hee-Jin
    • Asia-Pacific Journal of Business
    • /
    • v.10 no.1
    • /
    • pp.87-103
    • /
    • 2019
  • In December 2017, the Moon Jae-in administration announced a major policy shift away from nuclear and coal, committing itself to the vision of creating a society where renewable sources account for 20% of its electricity generation by 2030. This energy transition involves not just a technical transition from conventional energy sources to renewable energy but also active participation of multiple stakeholders in the energy governance. While energy policy making has long been dominated by the central government in Korea with the aim of managing the supply for rapid industrialization and economic growth, the Moon administration aims to diffuse the central government's authority across various actors in society. Among those actors, this study focuses on the roles that local governments play in energy transition. Despite deepening local autonomy since 1995, Korean local governments have remained policy targets or recipients in the energy policy domain. This article discusses how such a traditional role has evolved under the new administration's energy transition policy and examines what challenges and limitations local governments face in creating a more decentralized energy governance system.

Overcoming Electrical Energy Efficiency Gap in Nepal's Residential Sector

  • Thapa, Shahadev;Kim, Yun Seon
    • Asia Pacific Journal of Business Review
    • /
    • v.3 no.1
    • /
    • pp.19-38
    • /
    • 2018
  • The energy intensity of Nepal is economically not worthy, lacks eco-friendly and importantly not sustainable, and almost four times the average global energy intensity. Considerable efforts have been exercised to reduce the energy gap yet, it is still much to achieve. Nation priority on energy sector was envisaged with promulgation of investment friendly rules and law in hydropower and renewable technology even though, could not harness the sufficient energy. In amid of this acute energy crisis, the government launched the Nepal Energy Efficiency Programme (NEEP) with technical assistance from German International Cooperation (GIZ). Energy Efficiency (EE) practice is the most cost-effective method to reduce the supply and demand gap, reduce on greenhouse gases and pollution, and deter on import of petroleum products which finally improves on trade imbalance. This paper had proposed a framework of energy management team to promote energy efficient technologies in residential consumer. The energy management teams study the past records of energy use pattern of consumers and suggest appropriate technology for energy saving options. The paper provides some reviews of energy efficiency initiatives undertaken by the concern regulatory body which highlights the current status. The comprehensive knowledge acquired through exploratory research is implemented in this paper to identify the various barriers that domestic consumer is experiencing towards the active participation in energy efficiency program launched by the Government of Nepal.

Removal of Flooding in a PEM Fuel Cell at Cathode by Flexural Wave

  • Byun, Sun-Joon;Kwak, Dong-Kurl
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.104-114
    • /
    • 2019
  • Energy is an essential driving force for modern society. In particular, electricity has become the standard source of power for almost every aspect of life. Electric power runs lights, televisions, cell phones, laptops, etc. However, it has become apparent that the current methods of producing this most valuable commodity combustion of fossil fuels are of limited supply and has become detrimental for the Earth's environment. It is also self-evident, given the fact that these resources are non-renewable, that these sources of energy will eventually run out. One of the most promising alternatives to the burning of fossil fuel in the production of electric power is the proton exchange membrane (PEM) fuel cell. The PEM fuel cell is environmentally friendly and achieves much higher efficiencies than a combustion engine. Water management is an important issue of PEM fuel cell operation. Water is the product of the electrochemical reactions inside fuel cell. If liquid water accumulation becomes excessive in a fuel cell, water columns will clog the gas flow channel. This condition is referred to as flooding. A number of researchers have examined the water removal methods in order to improve the performance. In this paper, a new water removal method that investigates the use of vibro-acoustic methods is presented. Piezo-actuators are devices to generate the flexural wave and are attached at end of a cathode bipolar plate. The "flexural wave" is used to impart energy to resting droplets and thus cause movement of the droplets in the direction of the traveling wave.

Study of Pore Development Model in Low Rank Solid Fuel Using FERPM (FERPM을 적용한 저등급 고체연료의 기공발달 모델 특성 연구)

  • PARK, KYUNG-WON;KIM, GYEONG-MIN;JEON, CHUNG-HWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.178-187
    • /
    • 2019
  • Due to the increasing demand of high rank coal, the use of low rank coal, which has economically advantage, is rising in various industries using carbonaceous solid fuels. In addition, the severe disaster of global warming caused by greenhouse gas emissions is becoming more serious. The Republic of Korea set a goal to reduce greenhouse gas emissions by supporting the use of biomass from the Paris International Climate Change Conference and the 8th Basic Plan for Electricity Supply and Demand. In line with these worldwide trends, this paper focuses on investigating the combustibility of high rank coal Carboone, low rank coal Adaro from Indonesia, Baganuur from Mongolia and, In biomass, wood pellet and herbaceous type Kenaf were simulated as kinetic reactivity model. The accuracy of the pore development model were compared with experimental result and analyzed using carbon conversion and tau with grain model, random pore model, and flexibility-enhanced random pore model. In row lank coal and biomass, FERPM is well-matched kinetic model than GM and RPM to using numerical simulations.