  • Laos is rich in natural resources but lacks the capital to develop them. Partly alleviating the shortage is FDI from neighboring countries, especially Thailand. Not only does this contribute to directly increasing GDP by increasing effective demand, it also has an additional GDP increase effect by expanding Laos' production capacity. Laos' exports mostly consist of mineral resources and electricity. This, too, contributes to an increase in GDP by increasing the effective demand. Thailand accounts for more than 40 percent of Laos' exports. This paper tries to confirm the economic impact on Laos in Thailand through a econometric analysis of Laos' GDP, Laos' exports to Thailand and Thailand's FDI to Laos. It turns out that economic ties with Thailand, including exports to Thailand and Thailand's FDI, play a very important role in Laos' economic growth. Laos recently recorded relatively robust economic growth, but its driving force is weak. That's because Laos' growth engines are very limited and have no resilience to external shocks. Moreover, economic growth has not been linked to an increase in employment because the economy is not diversified and growth in the hydroelectric power sector does not lead to growth in other sectors. Given this, Laos needs to actively take advantage of its geographical proximity to Thailand. It is necessary to create a more active environment for the inflow of FDI in Thailand, to foster resource-based and labor-based manufacturing to take advantage of the Thai market.

Flow Analysis and an Experimental Study on Formation of Slurry Ice in the Reversing Flow Layer (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.421-428
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relieve a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This experimental study was carried out to observe flow pattern and formation of slurry ice in reversing flow layer to improve efficiency of heat transfer between fluid and freezing tube and to disturb ice adhesion on tube surface. The reversing flow layer was made by using reversing materials in heat exchanger section(test section) to disturb ice adhesion. At this experiment, styrofoam balls and poly propylene balls were used as reversing materials, and a 20wt% solution of ethylene glycol was used as reversing flow layer. The experimental apparatus was constructed of the test section for making/storing slurry ice, the brine tank, pumps for circulating of a 20wt% solution of ethylene glycol and brine, a flow-meter, a data logger for measuring the temperature. The experiments were carried out under various conditions, with volumetric flow rate, ball filling rate and air filling rate.

A financial feasibility study of the Mini-Solar Penal Subsidy Program in Seoul (서울시 태양광 보급 정책의 적정보조금 산정에 관한 연구 - 수용자적 입장에서의 재무성 분석을 중심으로 -)

  • Yeom, Sungchan;Lee, Eungkyoon
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.4
    • /
    • pp.317-331
    • /
    • 2015
  • A major barrier to the spread and vitalization of renewable energy lies in its economic infeasibility. And yet, there is a disparity in estimating the economic feasibility between supply and demand sides. Taking this into account, we calculate an appropriate level of mini-solar panel subsidies provided by the Seoul metropolitan government. More pointedly, this research investigates the receptivity and social equity of the subsidy program based on the analysis of the program's financial feasibility. The results show that the subsidies can have anticipated effects for the heavy electricity consumption group but not for the low electricity consumption group. Specifically, estimated pay-back periods for groups of 401kWh ~ 500kWh (per month) users, 201 kWh ~ 400kWh users and 101kWh ~ 200kWh were approximately 5years, 8 ~ 9 years and 12 years, respectively. This implies that differential scales of the subsidies can better contribute to reducing regressive difference between the groups and meeting the goal of social equity in regards to energy justice.

A Study on the Integration Costs in Korean Electric System in Accordance with Increasing Solar and Wind Power Generation (태양광·풍력 발전 증가에 따른 한국의 전력시스템 내 통합비용에 관한 연구)

  • Kim, Doo Chun;Kim, Kwang Jin;Park, Jung Gu
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.42-54
    • /
    • 2019
  • The solar and wind power is spreading as a means to $CO_2$ reduction, but it has the characteristics of the volatility depending on the weather changes. This article aims to estimate the additional integration costs in Korea electric system in response to such volatility of increasing solar and wind power generation, using Korea electric power trading analyzer(KEPTA). The analysis utilizes the statistics of "8th Basic Plan for Long-term Electricity Supply and Demand" and "Renewable Energy Plan 3020". As the results, integration costs will be estimated 13.94Won/kWh~32.55Won/kWh, consisting of 8.94Won/kWh as back-up costs, 1.03Won/kWh~4.45Won/kWh as balancing costs, and 3.97Won/kWh~19.16Won/kWh as grid-costs. These results suggest that when the integration costs are secured, Korea electric system will be expected in the stable situation. This article leaves the further studies with taking the technological development of solar and wind power generation, the introduction of energy storage system, and wholesale price of electricity into consideration.

Seismic Margin Assessment of Concrete Retaining Walls (콘크리트 옹벽의 지진여유도 평가)

  • Park, Duhee;Baeg, Jongmin;Park, Inn-Joon;Hwang, Kyeungmin;Jang, Jungbum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.7
    • /
    • pp.5-10
    • /
    • 2019
  • In recent Gyeongju and Pohang earthquakes, motions that exceed the design ground motion were recorded. This has led to adjustments to the design earthquake intensity in selected design guidelines. An increment in the design intensity requires reevaluation of all associated facilities, requiring extensive time and cost. Firstly, the seismic factor of safety of built concrete retaining walls are calculated. Secondly, the seismic margin of concrete retaining walls is evaluated. The design sections of concrete walls built at power plants and available site investigation reports are utilized. Widely used pseudo-static analysis method is used to evaluate the seismic performance. It is shown that all concrete walls are safe against the adjusted design ground motion. To determine the seismic margin of concrete walls, the critical accelerations, which is defined as the acceleration that causes the seismic factor of safety to exceed the allowable value, are calculated. The critical acceleration is calculated as 0.36g~0.8g. The limit accelerations are significantly higher than the design intensity and are demonstrated to have sufficient seismic margin. Therefore, it is concluded that the concrete retaining walls do not need to be reevaluated even if the design demand is increased up to 0.3g.

Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex (산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.65-79
    • /
    • 2019
  • The study attempted to estimate the optimal facility capacity by combining renewable energy sources that can be connected with gas CHP in industrial complexes. In particular, we reviewed industrial complexes subject to energy use plan from 2013 to 2016. Although the regional designation was excluded, Sejong industrial complex, which has a fuel usage of 38 thousand TOE annually and a high heat density of $92.6Gcal/km^2{\cdot}h$, was selected for research. And we analyzed the optimal operation model of CHP Hybrid System linking fuel cell and photovoltaic power generation using HOMER Pro, a renewable energy hybrid system economic analysis program. In addition, in order to improve the reliability of the research by analyzing not only the heat demand but also the heat demand patterns for the dominant sectors in the thermal energy, the main supply energy source of CHP, the economic benefits were added to compare the relative benefits. As a result, the total indirect heat demand of Sejong industrial complex under construction was 378,282 Gcal per year, of which paper industry accounted for 77.7%, which is 293,754 Gcal per year. For the entire industrial complex indirect heat demand, a single CHP has an optimal capacity of 30,000 kW. In this case, CHP shares 275,707 Gcal and 72.8% of heat production, while peak load boiler PLB shares 103,240 Gcal and 27.2%. In the CHP, fuel cell, and photovoltaic combinations, the optimum capacity is 30,000 kW, 5,000 kW, and 1,980 kW, respectively. At this time, CHP shared 275,940 Gcal, 72.8%, fuel cell 12,390 Gcal, 3.3%, and PLB 90,620 Gcal, 23.9%. The CHP capacity was not reduced because an uneconomical alternative was found that required excessive operation of the PLB for insufficient heat production resulting from the CHP capacity reduction. On the other hand, in terms of indirect heat demand for the paper industry, which is the dominant industry, the optimal capacity of CHP, fuel cell, and photovoltaic combination is 25,000 kW, 5,000 kW, and 2,000 kW. The heat production was analyzed to be CHP 225,053 Gcal, 76.5%, fuel cell 11,215 Gcal, 3.8%, PLB 58,012 Gcal, 19.7%. However, the economic analysis results of the current electricity market and gas market confirm that the return on investment is impossible. However, we confirmed that the CHP Hybrid System, which combines CHP, fuel cell, and solar power, can improve management conditions of about KRW 9.3 billion annually for a single CHP system.

Effect of Electroplating Parameters on Oxygen Evolution Reaction Characteristics of Raney Ni-Zn-Fe Electrode (Raney Ni-Zn-Fe 전극의 산소발생 반응 특성에 미치는 도금변수의 영향)

  • CHAE, JAEBYEONG;KIM, JONGWON;BAE, KIKWANG;PARK, CHUSIK;JEONG, SEONGUK;JUNG, KWANGJIN;KIM, YOUNGHO;KANG, KYOUNGSOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • The intermittent characteristics of renewable energy complicates the process of balancing supply with demand. Electrolysis technology can provide flexibility to grid management by converting electricity to hydrogen. Alkaline electrolysis has been recognized as established technology and utilized in industry for over 100 years. However, high overpotential of oxygen evolution reaction in alkaline water electrolysis reduces the overall efficiency and therefore requires the development of anode catalyst. In this study, Raney Ni-Zn-Fe electrode was prepared by electroplating and the electrode characteristics was studied by varying electroplating parameters like electrodeposition time, current density and substrate. The prepared Raney Ni-Zn-Fe electrode was electrochemically evaluated using linear sweep voltammetry. Physical and chemical analysis were conducted by scanning electron microscope, energy dispersive spectrometer, and X-ray diffraction. The plating time did not changed the morphology and composition of the electrode surface and showed a little effect on overpotential reduction. As the plating current density increased, Fe content on the surface increased and cauliflower-like structure appeared on the electrode surface. In particular, the overpotential of the electrode, which was prepared at the plating current density of 320 mA/㎠, has showed the lowest value of 268 mV at 50 mA/㎠. There was no distinguishable overpotential difference between the type of substrate for the electrodes prepared at 80 mA/㎠.

Study of Electric Charge Saving Plan Using High-speed Charging Wireless Railway System (급속충전방식 무가선 전동차 시스템을 이용한 전기요금 절감 방안 연구)

  • Go, Hyo-Sang;Cho, In-Ho;Ryu, Joon-Hyoung;Kim, Gil-Dong
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.31-42
    • /
    • 2017
  • Many studies have been performed to reduce electric consumption in railway systems. Due to its low conduction loss and high regenerative braking efficiency characteristics, the ESS powered railway system is chosen as a promising candidate for future railway systems. This paper introduces the ESS powered railway system and analyzes current power charge calculation methods that have been set up by KEPCO (Korea Electric Power Corporation). Based on the analysis, this paper proposes two different power charge reduction methods for the railway system. One is to smooth the peaks of traction energy consumption by supplying additional energy to the grid. The other is to save electric charge by reducing electric energy consumed by the railway during the energy peak time, 2 p.m.~5 p.m., which has highest 'Won/kWh' rates. To verify the effectiveness of the proposed method, the power charge of Seoul Metro Line 2 is recalculated using the method.

Cost-Effectiveness Evaluation of Energy Conservation Programs Using Avoided Operating Cost Calculation (운전회피비용 계산을 이용한 효율향상 프로그램의 비용효과 분석)

  • 김회철;이기송;박종배;신중린;신점구
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.317-323
    • /
    • 2002
  • This paper proposed the calculation method of the generation operating avoided cost to cost-effectiveness evaluation of energy conservation programs that compounded the Proxy Plant Method and Load Decrement Method. This method introduced an operating index of the Energy Efficiency Demand-Side Management (EEDSM) resources based on the end-user's behaviors on the electricity power usage. The operation index is applied to calculate the hourly operating capacity of diffused high-efficiency appliances. And the operating capacity on the peak load hours for reference load is computed through the reduction of the peak load that contributes to that hour. Also, the proposed method evaluated the effect of EEDSM resources. The IEEE-RTS is adopted as a sample system to analyze impacts of an EEDSM. This paper, we have analyzed the effect of EEDSM upon the changes in the generation of generator, generation cost and the system marginal price (SMP). This method can be used to evaluate the impact of the diffused DSM resource and to estimate the impact in short-term EEDSM program. Further, result of the calculation can be utilized to pabulum for effect analysis of EEDSM resources.

Evaluation of Implementation Potential of Offshore Wind Farm Capacity in Korea Using National Wind Map and Commercial Wind Farm Design Tool (국가바람지도와 상용 단지설계 프로그램을 활용한 국내 해상풍력단지 공급가능 잠재량 산정)

  • Song, Yuan;Kim, Chanjong;Paek, Insu;Kim, Hyungoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.21-29
    • /
    • 2016
  • Commercial wind farm design tools and the national wind map are used to determine the implementation potential of offshore wind power in Korea in this study. For this, the territorial waters of Korea were divided into nine analysis regions and a commercial CFD code was used to obtain wind resource maps at 100m A.S.L. which is the hub height of a 5MW wind turbine used in this study. With the wind resource obtained, factors including water depth, distance from substations, minimum and maximum capacity of a wind farm, distance between turbines and wind farms were considered to determine wind power potential. Also, the conservation areas, military zones, ports, fishing grounds, etc. were considered and excluded. As the result, a total capacity of 6,720 MW was found to be the implementation potential and this corresponds to $3.38MW/km^2$ in API. Also if the distance from the substation is not considered, the potential increased to be 10,040 MW. This offshore wind farm potential is considered enough to satisfy the target of wind farm capacities in the 7th national plan for electricity demand and supply.