• Title/Summary/Keyword: Electricity Demand Analysis

Search Result 258, Processing Time 0.08 seconds

A Study of Air-source Heat Pump Performance Analysis for Replacing Night Time Electric Heating Boiler (심야전기보일러 대체용 공기열 히트펌프 성능평가)

  • Jo, J.Y.;Jung, H;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2011
  • The night time electric cost is cheaper due to electric supply and demand policy in Korea from 1985. Currently about 900,000 customers are using night time electric heating boilers and this causes shift of peak demand time to night in winter and increase of deficit spending. To solve this problem, replacing night time electric heating boiler by air-source heat pump using night time electricity has been proposed. An air-source heat pump can provide efficient heating equipment especially in a warm climate. For estimating the night time electric heat pump COP(Coefficient of Performance), Korean Standard KS C 9306:2010 and European Standard EN-14511:2004 is available. SCOP(Seasonal COP) using European weather bin data is also calculated. SCOP is not available yet but European Committee for Standardization will establish a standard in the near future. The evaluation result show that the replacing night time electric heating boiler by heat pump can be possible.

Analysis of Power System Stability by Deployment of Renewable Energy Resources (재생에너지원 보급에 따른 전력계통 안정도 분석)

  • Kwak, Eun-Sup;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.633-642
    • /
    • 2021
  • Growing demand for electricity, when combined with the need to limit carbon emissions, drives a huge increase in renewable energy industry. In the electric power system, electricity supply always needs to be balanced with electricity demand and network losses to maintain safe, dependable, and stable system operation. There are three broad challenges when it comes to a power system with a high penetration of renewable energy: transient stability, small signal stability, and frequency stability. Transient stability analyze the system response to disturbances such as the loss of generation, line-switching operations, faults, and sudden load changes in the first several seconds following the disturbance. Small signal stability refers to the system's ability to maintain synchronization between generators and steady voltages when it is subjected to small perturbations such as incremental changes in system load. Frequency stability refers to the ability of a power system to maintain steady frequency following a severe system upset resulting in significant imbalance between generation and load. In this paper, we discusses these stability using system simulation by renewable energy deployment plan, and also analyses the influence of the renewable energy sources to the grid stability.

Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES (구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델)

  • Lee, Seung Jun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.99-120
    • /
    • 2017
  • In SS branch of Korea District Heating Corporation, Combined Heat & Power power plant with 99MW capacity and 98Gcal / h capacity is operated as a district electricity business. In this region, it is difficult to operate the generator due to the problem of surplus heat treatment between June and September due to the economic recession and the decrease in demand, so it is urgent to develop an economical energy new business model. In this study, we will develop an optimized operation model by introducing a renewable energy hybrid system based on actual operation data of this site. In particular, among renewable energy sources, fuel cell (Fuel Cell) power generation which can generate heat and electricity at the same time with limited location constraints, photovoltaic power generation which is representative renewable energy, ESS (Energy Storage System). HOMER (Hybrid Optimization of Multiple Energy Resources) program was used to select the optimal model. As a result of the economic analysis, 99MW CHP combined cycle power generation is the most economical in terms of net present cost (NPC), but 99MW CHP in terms of carbon emission trading and renewable energy certificate And 5MW fuel cells, and 521kW of solar power to supply electricity and heat than the supply of electricity and heat by 99MW CHP cogeneration power, it was shown that it is economically up to 247.5 billion won. we confirmed the results of the improvement of the zone electricity business condition by introducing the fuel cell and the renewable energy hybrid system as the optimization process model.

A Study on The Security Vulnerability Analysis of Open an Automatic Demand Response System (개방형 자동 수요 반응 시스템 보안 취약성 분석에 관한 연구)

  • Chae, Hyeon-Ho;Lee, June-Kyoung;Lee, Kyoung-Hak
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.333-339
    • /
    • 2016
  • Technology to optimize and utilize the use and supply of the electric power between consumer and supplier has been on the rise among the smart grid power market network in electric power demand management based on the Internet. Open Automated Demand Response system protocol, which can deliver Demand Response needed in electric power demand management to electricity supplier, system supplier and even the user is openADR 2.0b. This paper used the most credible, cosmopolitanly proliferated EPRI open source and analysed the variety of security vulnerability that developed VEN and VTN system may have. Using the simulator for attacking openADR protocol, the VEN/VTN system that has been implemented as EPRI open source was conducted to attack in a variety of ways. As a result of the analysis, we were able to get the results that the VEN/VTN system has security vulnerabilities to the parameter tampering attacks and service flow falsification attack. In conclusion, if you want to implement the openADR2.0b protocol system in the open or two-way communication environment smart grid network, considering a variety of security vulnerability should be sure to seek security technology and services.

LNG Gas Demand Forecasting in Incheon Port based on Data: Comparing Time Series Analysis and Artificial Neural Network (데이터 기반 인천항 LNG 수요예측 모형 개발: 시계열분석 및 인공신경망 모형 비교연구)

  • Beom-Soo Kim;Kwang-Sup Shin
    • The Journal of Bigdata
    • /
    • v.8 no.2
    • /
    • pp.165-175
    • /
    • 2023
  • LNG is a representative imported cargo at Incheon Port and has a relatively high contribution to the increase/decrease in overall cargo volume at Incheon Port. In addition, in the view point of nationwide, LNG is the one of the most important key resource to supply the gas and generate electricity. Thus, it is very essential to identify the factors that have impact on the demand fluctuation and build the appropriate forecasting model, which present the basic information to make balance between supply and demand of LNG and establish the plan for power generation. In this study, different to previous research based on macroscopic annual data, the weekly demand of LNG is converted from the cargo volume unloaded by LNG carriers. We have identified the periodicity and correlations among internal and external factors of demand variability. We have identified the input factors for predicting the LNG demand such as seasonality of weekly cargo volume, the peak power demand, and the reserved capacity of power supply. In addition, in order to predict LNG demand, considering the characteristics of the data, time series prediction with weekly LNG cargo volume as a dependent variable and prediction through an artificial neural network model were made, the suitability of the predictions was verified, and the optimal model was established through error comparison between performance and estimates.

Study on Stability Analysis for Systematic Impact Assessment at the Cooperation of Land in Offshore Wind Power Generation Demonstration Complex (해상풍력 실증 단지 육지 연계시 계통 영향 평가를 위한 안정도 해석에 관한 연구)

  • Park, Sang-ho;Kim, Kern-Joong;Han, Sangwook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.151-157
    • /
    • 2017
  • In this paper, it is the result of analysis of the stability by power system analysis about the influence on the power system when the southwest - offshore wind power demonstration complex is constructed to 60MW and it is linked with the onshore power system. Considering the position of the wind turbine actually installed and the length of the cooperating line, we modeled the wind generators, offshore substation and the turbine step-up transformer. Changes of voltage when internal and external faults occurred is analyzed and the reactive power demand according to the amount of electricity generation is derived. And also phase angle stability and frequency is observed through a transient analysis. This paper clarify that there is no problem in the system when only offshore wind power is linked with the grid and try to present the reactive power amount necessary for maintaining the voltage of the point of cooperation appropriately.

The Interconnection Technology of Small Self-generating System with Distribution Line

  • Park, Kyung-sun;Chiu Hwang
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-84
    • /
    • 1999
  • The demand of Small Self-generating System (SSS) including Small Cogeneration System (SCS) is constantly increasing with the need of electricity and/or thermal in office, hospital, hotel, and small factory, etc. It is especially recommended to operate SCS in the heat-following mode to maximize the efficiency of generator. In case of the heat-following mode SCS has got to be connected to distribution system so as to send surplus power to the utility or receive the short power from utility. But the interconnection of SSS with distribution system causes a few problems such as the bad power quality, and low security. If SSS is not promptly disconnected after faults occur (Islanding of SSS), it can not only damage equipment of utility and adjacent customers but also endanger life of human due to overvoltage or overcurrent. In this paper it has been deeply discussed if interconnection of engine self-generator/control system satisfies the protective requirement for SSS or not. 500 kW engine generator running in the Jodo island has been used to perform the analysis of interconnection.

  • PDF

Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System (교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구)

  • Jeon, Yong-Joo;Kang, Byoung-Wook;Chai, Hui-Seok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

Analysis of Electricity Demand Patterns using Load Profile Data (Load Profile을 이용한 수요자 그룹별 부하분석 연구)

  • Yu, In-Hyeob;Lee, Jin-Ki;Kim, Sut-Ic;Ko, Jong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.792-794
    • /
    • 2005
  • 최근에 들어서 전력산업에 규제완화가 도입되면서 환경이 급변하고 있는 실정이다. 여러 가지의 환경변화가 예상되지만, 그 중에서도 공급자간에 경쟁도입이 전력산업 참여자간에 주요 이슈로 부상하고 있다. 이와 같은 변화는 전력시스템의 기술 개발 뿐만 아니라 경영전략에도 큰 영향을 미치고 있으며, 대 수요자 서비스의 제공이 전략의 핵심이 되고 있다. 따라서 공급자는 보다 나은 서비스를 제공하기 위해서, 수요자 정보의 수집 및 분석을 해야 할 필요가 있다. 본 논문에서는 전력 수요자의 부하 특성을 분석하고 평가하기 위하여 수요특성별로 그룹으로 분류하는 방법을 개발하고, 분류된 그룹의 특징을 분석하였다. 이와 같은 부하분석의 정보는 가격설계, 수요 및 에너지 예측, 송전 및 배전계획, 에너지 효율 향상 및 부하관리의 필수 자료가 된다. 또한 향후에 개발될 전력 부가서비스의 주요 기반이 될 것으로 예상된다.

  • PDF

Analysis for Marketing Circumstance of Electric Power Value Added Service (전력 부가 서비스 시장 환경 조성에 대한 조사 분석)

  • Kim, Gi-Hyun;Park, Chee-Hyun;Lim, Young-Bae;Choi, Myeong-II;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.427-432
    • /
    • 2007
  • This paper research data and information for market environment of electric power value added service According to research, in USA using power line communication(PLC) and other communication device(ex ZigBee, Wireless and so on) online observation and building district management service were being realized Also, in Japan they are executing online electricity facility Igr monitoring service based on IT basic for checking insulation. Also we conduct a survey of H-SCP concept and demand for electric power value added service of Housewife and Working women. This paper will be used data for revitalizing market circumstance of electric power value added service.

  • PDF