DOI QR코드

DOI QR Code

Study on Stability Analysis for Systematic Impact Assessment at the Cooperation of Land in Offshore Wind Power Generation Demonstration Complex

해상풍력 실증 단지 육지 연계시 계통 영향 평가를 위한 안정도 해석에 관한 연구

  • Park, Sang-ho (Korea Electric Power Research Institute) ;
  • Kim, Kern-Joong (Dept. of Electrical Engineering, Chungnam National University) ;
  • Han, Sangwook (Dept. of Electrical Information Control, Dongseoul University)
  • Received : 2017.07.03
  • Accepted : 2017.11.21
  • Published : 2017.12.01

Abstract

In this paper, it is the result of analysis of the stability by power system analysis about the influence on the power system when the southwest - offshore wind power demonstration complex is constructed to 60MW and it is linked with the onshore power system. Considering the position of the wind turbine actually installed and the length of the cooperating line, we modeled the wind generators, offshore substation and the turbine step-up transformer. Changes of voltage when internal and external faults occurred is analyzed and the reactive power demand according to the amount of electricity generation is derived. And also phase angle stability and frequency is observed through a transient analysis. This paper clarify that there is no problem in the system when only offshore wind power is linked with the grid and try to present the reactive power amount necessary for maintaining the voltage of the point of cooperation appropriately.

Keywords

References

  1. S. H. Song, "Wind power to the offshore," The Korean Institute of Electrical Engineers, vol. 66, no. 11, pp. 47-54, 2010
  2. J. K. Sung and T. J. Lee, "Study on Present Status and Future Direction of Korean Offshore Wind Power", The Transactions of the Korean Institute of Electrical Engineers, vol. 62, no. 3, pp. 312-321, 2013 https://doi.org/10.5370/KIEE.2013.62.3.312
  3. W. S. Moon, J. N. Won, J. S. Huh, A. Jo and J. C. Kim, "Optimal Design of Power Grid and Location of Offshore Substation for Offshore Wind Power Plant," The Transactions of the Korean Institute of Electrical Engineers, vol. 64, no. 7, pp. 984-991, 2015 https://doi.org/10.5370/KIEE.2015.64.7.984
  4. C. S. Seo, G. G. Yoon, S. H. Park, Y. D. Choi and J. Y. Choi, "Analysis for PSCAD/EMTDC simulation of PMSG offshore wind generator," The Korean Institute of Electrical Engineers, Electrical device and energy conversion Society, pp. 262-264, 2013
  5. C. H. Min, D. Hur and J. K. Park, "Economic Evaluation of Offshore Wind Farm in Korea," The Transactions of the Korean Institute of Electrical Engineers, vol. 63, no. 9, pp. 1192-1198, 2014 https://doi.org/10.5370/KIEE.2014.63.9.1192
  6. W. S. Moon, A. Jo and J. C. Kim, "Economic Evaluation of Power Grid Interconnection between Offshore Wind Power Plants," The Transactions of the Korean Institute of Electrical Engineers, vol. 63P, no. 4, pp. 339-344, 2014