• Title/Summary/Keyword: Electrical uniformity

Search Result 597, Processing Time 0.028 seconds

Improvement of Power Capability and Field Uniformity with Tapered Coaxial Matching Units in Strip Line for Measuring Electromagnetic Immunity of Vehicular Components

  • Chung, Yeon-Choon;Kang, Tae-Won;Park, Dong-Chul
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.60-64
    • /
    • 1997
  • The design process and construction method of a strip line is described for measuring radiated susceptibility of vehicular components having electrical cables more than 2 min length. he characteristic impedance of the trip line was determined 90$\Omega$ to obtain the field uniformity of $\leq$${\pm}$3 dB in the frequency range from 100 kHz to 500 MHz. Tapered coaxial lines were used instead of the traditional lumped circuit element for the impedence matching units, therefore, the strip line has high power capability. Using these techniques, the field uniformity and power capability of a strip line could be considerably improved.

  • PDF

A Study on DOE Method to Optimize the Process Parameters for Cu CMP (구리 CMP 공정변수 최적화를 위한 실험계획법(DOE) 연구)

  • Choi, Min-Ho;Kim, Nam-Hoon;Kim, Sang-Yong;Chang, Eui-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.24-29
    • /
    • 2005
  • Chemical mechanical polishing (CMP) has been widely accepted for the global planarization of multi-layer structures in semiconductor manufacturing. Copper has been the candidate metallization material for ultra-large scale integrated circuits (ULSIs), owing to its excellent electro-migration resistance and low electrical resistance. However, it still has various problems in copper CMP process. Thus, it is important to understand the effect of the process variables such as turntable speed, head speed, down force and back pressure are very important parameters that must be carefully formulated in order to achieve desired the removal rates and non-uniformity. Using a design of experiment (DOE) approach, this study was performed investigating the main effect of the variables and the interaction between the various parameters during CMP. A better understanding of the interaction behavior between the various parameters and the effect on removal rate, non-uniformity and ETC (edge to center) is achieved by using the statistical analysis techniques. In the experimental tests, the optimum parameters which were derived from the statistical analysis could be found for higher removal rate and lower non-uniformity through the above DOE results.

An Improvement of the Field Uniformity inside the Reverberation Chamber with Inclined QRD Set (경사진 QRD를 이용한 전자파 잔향실 내 전자기장 균일도 향상을 위한 연구)

  • Lee, Byoung-Jun;Kim, Hye-Kwang;Rhee, Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.577-583
    • /
    • 2007
  • The field uniformity inside the reverberation chamber has been improved using sets of quadratic residue diffuser (QRD). The electromagnetic field inside the reverberation chamber with the dimension of $100{\times}80{\times}80cm$ has been analyzed by the finite-difference time-domain(FDTD) method. The calculated fields in a $40{\times}30{\times}30cm$ test volume have been sampled to obtain a standard deviation and field uniformity. Results show that the standard deviation of the calculated field and uniformity have been improved by varying angles and orientation of the inclined surfaces of the QRDs installed inside the reverberation chamber.

Study of Optimized Reflector Design for Road Light Using Ray-Tracing Method (광선추적법을 사용한 가로등 반사판의 최적설계에 관한 연구)

  • Choi, Dae-Seub;Han, Jeong-Min;Shim, Yong-Sik;Jeong, Chan-Oong;Oh, Seon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.347-350
    • /
    • 2009
  • In this study, it was studied about the improved road light design for drivers and pedestrians using forward or reverse ray-tracing method. Many of conventional road lights are not suitable for drivers and pedestrians because it has some serious problems such as glare effect or randomicity of illuminated areas. It was oriented from customary design method which was pointed at simple target such as luminance or electrical power. But it was not truth any more that the high luminance or electrical power consumption mean more bright and good road light. We studied ray-tracing method for road light reflector design to get the several goals. It means that good road light has easy for drivers and pedestrians eyes and illuminating objects on the road clearly. So, we set the design targets such as uniformity on the road area per one road light, shading angles and continuous luminance uniformity on the long distance road. We designed ideal road light conditions using ray-tracing method. We set the height of drivers and pedestrians eyes and calculated design guideline to make above design targets. Then we designed road light reflector using reverse ray-tracing method. And we achieved same luminance on the road almost half power consumption because we reduced loss of light. We achieved ideal design guide as 75 degrees of shading angles and 0.5 of luminance uniformity on the road area. It is superior than conventional road light ability such as 0.35 of luminance uniformity of 400 watts power consumption lamp. Finally, we suggested reflector design for 250 watts power consumption CDM Iight source.

Design of a Guide Vane for Improving Inside Flow Uniformity of Electrostatic Precipitator (전기집진기 내부의 유동 균일성 향상을 위한 가이드 배인의 최적설계)

  • Noh, Kyung-Wook;Bae, Seong-Jun;Park, Sookhee;Kang, Sunkyun;Lee, Jangmyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • In recent years, many efforts are increasingly being made to conserve the natural environment with enhanced emission standards and air quality standards. Also there are various methods necessary to be researched to minimize the emission of air pollutants. In particular, boilers of industrial facilities are major portions of the air pollution. The front duct which needs to be designed to reduce the gases to the electrostatic precipitator requires a bent tube, a reduction/extend tube and an auxiliary equipment, that is, a guide vane. This paper proposes an optimum design of the guide vane by a case study for electrostatic precipitator's flow uniformity. The operating conditions of this study are as follows: BMCR (Boiler Maximum Continuous Rate) and MGR (Maximum Guaranteed Rate) are 75%, 50%, and 30%; turbulent fluid dynamics model is based upon K-${\varepsilon}$ formulation. Presentation of the computed motion of particles is found to be quite useful to predict the precipitator performance by use CFD (Computational Fluid Dynamics).

Reducing the Poly-Si TFT Non-Uniformity by Transistor Slicing

  • Lee, Min-Ho;Lee, In-Hwan
    • Journal of Information Display
    • /
    • v.2 no.2
    • /
    • pp.27-31
    • /
    • 2001
  • Transistor slicing refers to the use of multiple smaller transistors in implementing a large MOS transistor. What is special about transistor slicing is that it can reduce the effects of device non-uniformity introduced during the fabrication process. The paper presents the idea of transistor slicing and analyzes the benefits of using transistor slicing in the context of Poly-Si TFT-LCD driving.

  • PDF

Influence upon electrical properties of outdoor insulators with non-uniformity contamination (국부오손이 옥외절연물의 전기적 특성에 미치는 영향)

  • 이원영;최남호;박강식;한상옥
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.203-206
    • /
    • 2001
  • Since th three sides of korea peninsula are surrounded by the sea, electric apparatus are greatly contaminated by the salt generated by the typhoon, seasonal wind, sea wind and sea fog. This contamination causes electric power apparatus to fail. Thus in this paper, we investigated to influence upon electrical properties of outdoor insulators with non-uniformity contamination in the experimental condition because The contamination of outdoor insulator highly depended wind property In the service condition, insulator was not uniformly contaminated. From the flashover test for the 254 mm suspension insulator, we could determine the influence non-uniform contamination on the electrical property of insulators. Through the experiment, we convinced to occur flashover from non-uniform contamination region of outdoor insulator. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

Design and Evaluation of LCD Backlight Unit by LED Array Modules

  • Aung, Aye Thida;Lee, Seung-Min;Yang, Jong-Kyung;Park, Dae-Hee;Lee, Seong-Jin;Lee, Jong-Chan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.110-115
    • /
    • 2008
  • In this paper, we have designated a 42-inch RGB LED BLU, 80 % above illuminance. A desirable brightness performance was attained, by doing anti-parallel configuration, a fitting of LED's strip distance and a height of the top of LED to the back of the LCD. We get the 85.81 % of the brightness uniformity which has 12.8 mm away from LED's top and LCD's back and 51.41 mm of the same spacing between LED's strip in simulation and 82.24 % in experiment.

Powder Type Electroluminescence Display with Good Uniformity for LCD Backlighting (LCD 후면 광원용으로 우수한 Uniformity를 갖는 분산형 EL)

  • Kwon, S.S.;Lim, M.S.;Lim, K.J.;Park, S.G.;Ryu, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.776-778
    • /
    • 1998
  • Electrical and optical characteristics of Powder type EL display(P-ELD) in this study are described, In experimental results of V-J, current are increased with increasing the frequency and voltage. Luminance was increased with frequency. This is due to the positive space charge formed to cathode region. Lumiance at 150V, 20 kHz has $840\;cd/m^2$. This tendency is due to the decrease of capacitive reactance in insulator layer. Uniformity of P-ELD shows 97%. CIE chromaticity with increasing frequency are shifted toward blue color. It can be explained in tenn of the difference of recombination energy.

  • PDF