• 제목/요약/키워드: Electrical treeing

검색결과 126건 처리시간 0.026초

PCA-LDA 알고리즘을 이용한 고체절연물의 열화도 판별 (Evaluation on Degradation of Solid Insulator by PCA-LDA algorithm)

  • 박성희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2079-2081
    • /
    • 2005
  • Electrical treeing occurrence is caused by some defect in solid insulator. Those are accompany the PD(partial discharge) occurrence. And lifetime of the insulator is affected by PD. So, detection of electrical treeing is important thing as this view. Especially, detection of the end treeing is more important and have meaning for industrial engineering because concerned with maintenance and replacement of equipment. In this paper, evaluation of treeing process were studied and PCA(principle component analysis)-LDA(linear discriminant analysis) as classification method were used. The result is present the good recognition.

  • PDF

DGEBA/MDA/GN 계에서 AC 트링열화의 온도의존성 (Temperature Dependence of AC Treeing Deterioration in DGEBA/MDA/GN System)

  • 안현수;심미자;박수길;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.425-428
    • /
    • 1996
  • Treeing deterioration which is one of the main cause of breakdown in insulating materials is affected by temperature, applied voltage and frequency. In this study, GN was introduced to improve impact strength of DGEBA/MDA system and the temperature dependence of AC treeing deterioration in this system was investigated. Dielectric breakdown strength decreased with the increment of temperature. As temperature increased, the growth rate of tree Increased.

  • PDF

Long-term AC Electrical Treeing Behaviors of Epoxy/Layered Silicate Nanocomposites Prepared by a 3-Roll Mill

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.85-88
    • /
    • 2012
  • Studies on the effects of layered silicate content on the AC electrical treeing and breakdown behaviors of epoxy/layered silicate nanocomposites were carried out in needle-plate electrode geometry. Wide-angle X-ray diffraction (WAXD) analysis and transmission electron microscopy (TEM) observation showed that 1 wt% of the multilayered silicate was fully exfoliated into nano-sized monolayers in the epoxy matrix however, over 3 wt% of the silicate was in an intercalated state. When 1 wt% layered silicates were incorporated, an electrical tree was initiated in 439 min and propagated at a speed of 2.3 ${\mu}m$/min after applying 781.4 kV/mm, representing a decreased in starting initiation time by a factor of 11.0 and increase in propagation speed by a factor 8.2 in comparison with neat epoxy resin. These values were in great decline after the layered silicate content was increased to 3wt% which implies that the exfoliated silicate blocked the tree initiation and propagation processes effectively. However the effect was largely decreased in the intercalated state.

XLPE 케이블의 트리잉 열화에 따른 음향방출 특성 (Title: A Characteristics of Acoustic Emission according to Treeing Deterioraction in Crosslinked Polyethylene Cable)

  • 조대연;김명호;백관현;심종탁;박재준;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.973-975
    • /
    • 1992
  • The Acoustic Emission due to treeing progress in Crosslinked Polyethylene(XLPE) is studied by using the self developed automatic measuring system of acoustic emission. Tree progression and average pulse amplitude are almost in proportion to the rising of applied voltage but there is no proportionality relation between tree progression and pulse numbers. From now on, Skewness and kurtosis of average cycle, special property of $\phi$-a distribution characteristics can be confirmed as the useful parameters of treeing deterioration.

  • PDF

첨가재에 의한 저밀도 폴리에틸렌의 내트리잉성 향상 (Improvement of the resistance to Treeing by additive in Low Density Polyethylene)

  • 김봉협;임기조
    • 대한전기학회논문지
    • /
    • 제35권1호
    • /
    • pp.17-25
    • /
    • 1986
  • Discussions on this paper are related to the effects of organic materials to treeing phenomena of low density polyethylene. As additives, 11 kinds of organic compounds are selected by considering the respective features such as melting point, boiling point, electron affinity as well as molecular structure, and then the specimens of low density polyethylene are prepared by blending with 10wt% of the selected additives. For the comparison of effectiveness of treeing resistance and interpretation of the mechanism of compounds as treeing retardants, several investigations such as the tree acceleration test, the prestressed test and the measurement of internally occurred partial discharge are carried out. As the results, meta-Cresol is regard as the most effective retardant among those, and it is supposed that this aromatic compound to be comprised of radical having large electron affinity has strong capability to accept energetic electron to prevent or delay the growth of discharge streamer. Furthermore, by activating partial discharge at the wall of tree pit through the function of trapped electron at this material, the gas pressure in the pit is increased up to prevent the growth of streamer.

  • PDF

Aniline이 첨가된 LDPE에서 부분방전 펄스 분석에 의한 트리성장 길이의 인식 (RECOGNITION OF TREE GROWING USING PD SIGNAL ANALYSIS IN LOW DENSITY POLYERHYLENE BLENDED WITH ANILINE)

  • 육형상;강성화;임기조;박수길;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.202-205
    • /
    • 1994
  • There is a close relation between electrical treeing and internal partial discharges in solid dielectrics. In this paper, the characteristics of electrical treeing and partial discharge in solid dielectrics are investigated. We carried out the measurements of electrical treeing and PD(partial discharge) characteristics. From the experimental results, we found out that maximum PD magnitude increased linearly with time at first stage, thereafter increased remarkably. These tendencies are very similar to the characteristics of tree growth with time.

Effect of an Electric Field on the AC Electrical Treeing in Various Epoxy/Reactive Diluent Systems

  • Bang, Jeong-Hwan;Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.308-311
    • /
    • 2013
  • The effect of an electric field on the ac electrical treeing in various epoxy/reactive diluent systems was studied in a needle-plate electrode geometry. Diglycidyl ether of bisphenol A (DGEBA) type epoxy was used as a base resin, and 1,4-butanediol diglycidyl ether (BDGE) or polyglycol (PG) as a reactive diluent was introduced to the DGEBA system, in order to decrease the viscosity of the DGEBA epoxy system. BDGE was acted as a chain extender, and PG acted as a flexibilizer, after the curing reaction. To measure the treeing initiation time and the propagation rate, three constant alternating currents (ac) of 10, 13 and 15 kV/4.2 mm (60 Hz) were applied to the specimen, in a needle-plate electrode arrangement, at $30^{\circ}C$ of insulating oil bath. When 10 kV/4.2 mm (60 Hz) was applied, the treeing initiation time and the propagation rate in the DGEBA system were 356 min and $1.10{\times}10^{-3}$ mm/min, respectively, those in the DGEBA/BDGE system were 150 min and $1.14{\times}10^{-3}$ mm/min, respectively. Those in the DGEBA/PG system were 469 min and $1.05{\times}10^{-3}$ mm/min, respectively. As 15 kV/4.2 mm (60 Hz) was applied, the propagation rate in the DGEBA system was $5.41{\times}10^{-3}$ mm/min, and that in the DGEBA/PG system was $1.42{\times}10^{-3}$ mm/min. These values meant that PG could be used as a reactive diluent in the DGEBA system, without the deterioration of the insulation breakdown property.

첨가제를 함유한 저밀도 폴리에틸렌의 절연특성에 관한 연구 (A Study on Insulation Characteristics of Low Density Polyethylene Contained Various Additives)

  • 이청;김규백;류부형;김기엽;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.483-486
    • /
    • 1999
  • The treeing inhibitors of barbituric acid derivatives and azocompounds effects on the electrical properties of crosslinked low density polyethylene were investigated. The electrical treeing parameters for tree inception voltage, AC breakdown strength. volume resistivity, capacitance and dissipation factor at 1Mz and thermoluminescence measurements were discussed. From the results, 4- (4-nitrophenylazo) resorcinol among the treeing inhibitors was shown good insulation characteristics.

  • PDF

국산유기절연재료의 Treeing현상 (Treeing Phenomena in the Home-made Solid Organic Insulating Materials)

  • 성영권;이헌용;이계호;유기한
    • 전기의세계
    • /
    • 제26권2호
    • /
    • pp.57-65
    • /
    • 1977
  • In roder to investigate the influence of treeing on electric breakdown of solid organic insulator the initiation and growing mechanism of tree itself, and the correlation between corona discharge and treeing phenomena in solid orgainc insulating materials, several experiments were carried out by means of needle test on polymethyl-methacrylate. The obtained results showed that the existence of voids in specimen had important effects on initiation voltage of trees and, when the direct voltage was applied, the initiation voltage of trees increased by space charge effect. And also the stagnation phenomena due to the transfer of vacancy cluster or polymekr cage in specimen might beconsidered in process of growth of trees, and corona discharge seemed to be the pre-phenomena of treeing because trees were normally initiated by internal discharge in voids.

  • PDF

해저케이블의 열화진단을 위한 트리잉의 화상처리 (Image Processing of Treeing for Diagnosis of Deterioration in Submarine Cable)

  • 이재봉;임장섭;박현빈;구할본;김태성;요시무라 노보루
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 1994
  • To measure treeing, visual measurement with an optical microscope has been used to explain breakdown mechanism by treeing in materials. The conventional direct visual method of tree deterioration observation is difficult to measure in short time processing, and impossible to analyze the deteriorated area by treeing, direction of tree growth, tree patterns etc. In this paper, we have developed a tree-measuring system using image processing for the tree growth, the area of deterioration, and other progresses of treeing. As experimental result, image processing is an effective alternative to direct visual observation method.

  • PDF