• 제목/요약/키워드: Electrical shock

검색결과 407건 처리시간 0.026초

선내 자동 부하분담 제어시스템에 관한 연구 (A Study of the Control System for a Auto Loadsharing of the ship)

  • 이효성;임용곤;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3025-3027
    • /
    • 2005
  • As the energy and manpower saving in ship have been prominent figures since oil shock, resonable operation modes of propulsion and generating plants were made a through study for the practical use. Through the results of it, advanced countries developed the load-sharing system for the generator automation and could be realized the energy and manpower saving in ship.

  • PDF

고기동 유도탄 HILS를 위한 비행자세모의기 최적 경로 산출 (Optimal Path Generation of Flight Motion Simulator for Hardware in the Loop Simulation)

  • 김기승;나원상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.117-119
    • /
    • 2004
  • An optimal flight motion simulator path generation method is proposed for hardware in the loop simulation of high maneuverable missile. The proposed method consists of open loop and closed loop path calculation algorithm based on the energy optimal control strategies. The optimal angle command is able to protect the simulator from high acceleration shock at initial control phase.

  • PDF

가시광 스펙트럼 영역에서 선택적인 투과와 내열충격성을 갖는 LAS계 글라스세라믹의 특성 (Characteristics of glass-ceramics of LAS system having high thermal shock resistance and selective transparency in visible region of spectrum)

  • 변우봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1565-1567
    • /
    • 2003
  • LAS($Li_2O-Al_2O_3-SiO_2$)계에 전이금속과 희토류 이온을 첨가한 글라스세라믹의 colouring에 대한 특성 분석이 이루어졌다. 투과성이 높고, 내열 충격성이 우수한 글라스세라믹을 제조한 수 있었으며, 주 결정상은 ${\beta}$-eucryptite(SS)이었다. 또한 colouring에 의한 빛의 흡수 특성과 이러한 글라스세라믹에서의 colouring 이온의 구조적 상태가 조사되었다.

  • PDF

인체모형을 이용한 감전사고 모의와 프로그램 분석 (The Simulation of Electric Shock Fault and Program Analysis using a Human-body Model)

  • 장태준;정연하;노영수;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.126-128
    • /
    • 2004
  • 본 연구에서는 인체모형을 이용하여 감전사고를 모의하고, 프로그램을 이용하여 해석하였다. 그리고 실험결과를 국내 감전사고자의 통계자료와 비교하였다. 향후 더 많은 사고모델에 대한 자료를 축적하면 감전사고 메커니즘을 체계적이고 정량적으로 입증할 수 있고, 이것은 관리자의 전기설비 이용요령, 사용자의 휴먼에러(human error)를 최소화할 수 있는 자료로 활용될 수 있을 것으로 기대된다.

  • PDF

충격에너지를 활용한 압전 발전기의 특성을 이해하기 위한 실험 연구 (A Experimental Study to Understand of a Characteristics of a Piezo-Generator using Impact Energy)

  • 이재준;문학룡;권수안;류승기
    • 대한토목학회논문집
    • /
    • 제31권5D호
    • /
    • pp.689-695
    • /
    • 2011
  • 본 논문에서는 도로공간에서 전력 생성이 가능한 신재생 에너지 기술들 중에서 압전효과를 활용하는 방법에 대한 연구를 수행하였다. 도로공간을 주행하는 수많은 차량을 이용하여 전력을 생성할 수 있는 신재생에너지 기술 연구의 일환으로, 외부의 충격하중을 전기에너지로 바꾸어 주는 압전효과를 이용하여 도로공간에 적용가능한 압전발전기를 개발하기 위한 기초연구를 수행하였다. 압전세라믹을 이용한 압전발전 수확기를 개발하기 위한 충격하중에 따른 특성 실험을 하였다. 압전발전기 형상 개발을 위해 충격하중 전달 방법, 충격흡수에 따른 압전세라믹의 발전 특성, 충격하중의 종류에 따른 압전 발전 수확기의 전압 발전 특성을 비교분석 하였다.

태양광발전시스템용 직류 누설전류 센서 개발 (Development of DC Leakage Current Sensor for Solar Power Generation System)

  • 김희선;한송엽;한후석
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.828-833
    • /
    • 2014
  • Grid connected transformerless solar power generation system is frequently used with the benefits of cost and efficiency. However, significant DC leakage current can flow from the DC line into the ground with dielectric breakdown in the transformerless solar power generation system. The leakage current occurred in the DC line causes accidents such as fire and electric shock on human. To resolve this problem, high sensitivity DC leakage current sensor is needed. But recently the studies on safety of DC line are not performed. In this paper, a high sensitivity DC leakage current sensor that can detect DC leakage current in solar power generation system, is proposed. Based on the studies, DC leakage current sensor is fabricated and characteristic tests are carried out. Finally, the accuracy of sensor performance is verified by leakage current experiments in solar power generation system.

과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge)

  • 박현준;장동욱;이길헌;최종선;김저우
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

누전차단기 동작시간 및 부동작 전류 특성 (A Study on the Cutoff time and the Malfunction Current Characteristics of RCDs)

  • 한운기;송길목;김영석;김동욱;최충석;이복영;박상태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.61-65
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCDs are employed at temporary power sites and electrical facilities on the road they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing improved advanced in their performance.

  • PDF

A CONCEPTUAL DESIGN FOR ELECTRICAL GROUNDING ARCHITECTURE OF KOREAN SPACE LAUNCH VEHICLE

  • Kim Kwang-Soo;Lee Soo-Jin;Ma Keun-Soo;Shin Myoung-Ho;Hwang Seung-Hyun;Ji Ki-Man;Chung Eui-Seung
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.231-234
    • /
    • 2004
  • Electrical grounding is defined as referencing an electrical circuit or a common reference plane for preventing shock hazards and for enhancing operability of the circuit and EMI control. In order to realize the best electrical grounding system of korean space launch vehicle, we should design the electrical grounding architecture of korean space launch vehicle of system-level at the earliest point in design procedure. To minimize the electrical grounding loop and the unnecessary electromagnetic interference or radiation among the electronic subsystems, we should establish the electrical grounding rules of the all electrical interfaces. The electrical interfaces among the electronic subsystems are generally classified into the electrical power and signal interfaces. Because of using the primary and secondary power system architecture in the korean space launch vehicle system such as the common space launch vehicle systems, we need to establish the electrical grounding rules between the primary and secondary power system. We also need to establish the electrical signal grounding interface rules among the electronic subsystems. In this paper, we will describe the grounding schemes of the common space launch vehicle system and propose a conceptual design for the electrical grounding architecture of korean space launch vehicle system.

  • PDF

대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석 (Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment)

  • 채동주;김영석;정진수;임현성;조성구;홍성준
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.