• Title/Summary/Keyword: Electrical resistance change

Search Result 500, Processing Time 0.037 seconds

Self-diagnosis property of strengthened concrete by rib of hybrid FRP and carbon fiber sheet (하이브리드FRP 탄소계 리브 및 탄소섬유시트 보강 콘크리트의 자가진단 기능 검토)

  • Park, Seok-Kyun;Kim, Dae-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.358-361
    • /
    • 2006
  • For giving self-diagnosing capability, a method based on monitoring the changes in the electrical resistance of carbon materials in strengthened concrete has been tested. Then after examining change in the value of electrical resistance of carbon materials used as a rib of CFGFRP or a sheet of carbon fiber before and after the occurrence of cracks and fracture in hybrid FRP or carbon fiber sheet strengthened concrete at each flexural weight-stage, the correlations of each factors were analyzed.

  • PDF

Electrical Resistance of Mo-doped $VO_2$ Films Coated on Graphite Conductive Plates by a Sol-gel Method (몰리브덴이 첨가된 이산화바나듐으로 표면처리한 탄소계 전도성판의 전기저항특성)

  • Choi, Won-Gyu;Jung, Hye-Mi;Lee, Jong-Hyun;Im, Se-Joon;Um, Suk-Kee
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2007-2010
    • /
    • 2008
  • Vanadium pentoxide ($V_2O_5$) powder was prepared and mixed with Molybdenum Oxides ($MoM_3$) to form Mo-doped and -undoped $VO_2$ films by a sol-gel method on graphite conductive substrates. X-Ray diffraction (XRD) and scanning electron microscopy (SEM) was used to investigate the chemical compositions and microstructures of the Mo-doped and -undoped $VO_2$ films. The variation of electrical resistance was measured as a function of temperature and stoichiometric composition between vanadium and molybdenum. In this study, it was found that Mo-doped and -undoped $VO_2$ shows the typical negative temperature coefficient (NTC) behavior. As the amount of the molybdenum increases, the electrical resistance of Modoped $VO_2$ film gets reduced under the transition temperature and a linear decrease in the transition temperature is observed. From these experimental results, we can conclude that the electrical resistance behavior with temperature change of $VO_2$ films can be utilized as a self-heating source with the electrical current flowing through the graphite substrate.

  • PDF

Electrical Switching Characteristics of Ge1Se1Te2 Chalcogenide Thin Film for Phase Change Memory

  • Lee, Jae-Min;Yeo, Cheol-Ho;Shin, Kyung;Chung, Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • The changes of the electrical conductivity in chalcogenide amorphous semiconductors, $Ge_{1}Se_{1}Te_{2}$, have been studied. A phase change random access memory (PRAM) device without an access transistor is successfully fabricated with the $Ge_{1}Se_{1}Te_{2}$-phase-change resistor, which has much higher electrical resistivity than $Ge_{2}Sb_{2}Te_{5}$ and its electric resistivity can be varied by the factor of $10^5$ times, relating with the degree of crystallization. 100 nm thick $Ge_{1}Se_{1}Te_{2}$ thin film was formed by vacuum deposition at $1.5{\times}10^{-5}$ Torr. The static mode switching (DC test) is tested for the $100\;{\mu}m-sized$ $Ge_{1}Se_{1}Te_{2}$ PRAM device. In the first sweep, the amorphous $Ge_{1}Se_{1}Te_{2}$ thin film showed a high resistance state at low voltage region. However, when it reached to the threshold voltage, $V_{th}$, the electrical resistance of device was drastically reduced through the formation of an electrically conducting path. The pulsed mode switching of the $20{\mu}m-sized$ $Ge_{1}Se_{1}Te_{2}$ PRAM device showed that the reset of device was done with a 80 ns-8.6 V pulse and the set of device was done with a 200 ns-4.3 V pulse.

Analysis for Force Distribution on Surface Between Busbar Contacts (부스바 접점 가동시 접촉면에서 압점력 해석)

  • Oh, Y.H.;Song, K.D.;Kim, K.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

Percolation threshold and piezoresistive response of multi-wall carbon nanotube/cement composites

  • Nam, I.W.;Souri, H.;Lee, H.K.
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.217-231
    • /
    • 2016
  • The present work aims to develop piezoresistive sensors of excellent piezoresistive response attributable to change in nanoscale structures of multi-wall carbon nanotube (MWNT) embedded in cement. MWNT was distributed in a cement matrix by means of polymer wrapping method in tandem with the ultrasonication process. DC conductivity of the prepared samples exhibited the electrical percolation behavior and therefore the dispersion method adopted in this study was deemed effective. The integrity of piezoresistive response of the sensors was assessed in terms of stability, the maximum electrical resistance change rate, and sensitivity. A composite sensor with MWNT 0.2 wt.% showed the lowest stability and sensitivity, while the maximum electrical resistance change rate exhibited by this sample was the highest (96 %) among others and even higher than those found in the literature. This observation was presumably attributed by the percolation threshold and the tunneling effect. As a result of the MWNT content (0.2 wt.%) of the sensor being near the percolation threshold (0.25 wt.%), MWNTs were close to each other to trigger tunneling in response of external loading. The sensor with MWNT 0.2 wt.% was able to maintain the repeatable sensing capability while sustaining a vehicular loading on road, demonstrating the feasibility in traffic flow sensing application.

Research for the Substitutional Grounding Electrode in the Foundation of the House (주택기초의 대용 접지극에 관한 연구)

  • Kim, Sung-Sam;Lee, Chung-Sik;Choi, Jong-Kyu;Kim, Ju-Chan;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.355-358
    • /
    • 2005
  • The electrical characteristics for applying the foundation of the house to the substitutional earth electrode was reviewed fundamentally. In order to measure the earth resistance in the foundation of the house, it was performed to investigate the effect of the electrode arrangements and configurations concerning to grounding methods, and tried to the adequate simulation for comparing those experimental data. The number of steel rods and the ground resistivity were affected to change the earth resistance, but the latter caused the large variation in its resistance compared to the former in this experiment. Since the large surface area in the foundation of the house have contacted the ground usually, it is possible to use the earth electrode substitutionally.

  • PDF

Self- Diagnosis of Damage in Hybrid FRP Reinforced Concrete (하이브리드 FRP보강근 콘크리트의 손상 자가진단)

  • Park Seok-Kyun;Kim Dae Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.233-237
    • /
    • 2005
  • For giving self-diagnosing capability, a method based on monitoring the changes in the electrical resistance of hybrid FRP reinforced concrete has been tested. Then after examining change in the value of electrical resistance of carbon fiber in CFRP, CFGFRP, CFAFRP and e.t.c., before and after the occurrence of cracks and fracture in hybrid FRP reinforced concrete at each flexural weight-stage, the correlations of each factors were analyzed. As the results, it is clarified that when the carbon fiber tows fracture, the electrical resistance of it increase largely, and afterwards hybrid FRP composites can be resist the load due to the presence of the reinforced fiber, for example, glass fiber or aramid fiber tows.

  • PDF

Preparation of Magnetic Field Sensor with YBaCuO Superconducting Ceramics (YBaCuO계 초전도소결체 자기소자)

  • 이상헌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.109-111
    • /
    • 2000
  • A magnetic field sensor is fabricated with superconducting ceramics of Y-Ba-Cu-O system. The prepared material shows the superconductivity at about 95K. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value more than 100$\mu$V by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The sensing limit is about $1.5\times$$10^{-5}$ (=1.5$\times$$10^{-1}$ G). The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

Magnetic Sensor by Using Magnetic Effect in YBaCuO Superconductor

  • 이상헌;김찬중
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.69-71
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of YBaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually the voltage drop across the sensor was changed from zero to a value more than 100 $mutextrm{V}$ by the applied magnetic field. The change in electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about $1.5\times$10$^{-5}$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.