• Title/Summary/Keyword: Electrical network

검색결과 6,485건 처리시간 0.04초

아날로그 홉필드 신경망의 모듈형 설계 (Modular Design of Analog Hopfield Network)

  • 동성수;박성범;이종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.189-192
    • /
    • 1991
  • This paper presents a modular structure design of analog Hopfield neural network. Each multiplier consists of four MOS transistors which are connected to an op-amp at the front end of a neuron. A pair of MOS transistor is used in order to maintain linear operation of the synapse and can produce positive or negative synaptic weight. This architecture can be expandable to any size neural network by forming tree structure. By altering the connections, other nework paradigms can also be implemented using this basic modules. The stength of this approach is the expandability and the general applicability. The layout design of a four-neuron fully connected feedback neural network is presented and is simulated using SPICE. The network shows correct retrival of distorted patterns.

  • PDF

송전제약하에서 DC LOAD FLOW를 이용한 한계비용의 분석과 계통의 분할에 관한 연구 (A Study on the analysis of marginal cost using DC load flow in transmission constraint and network partition)

  • 장시진;정해성;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.373-375
    • /
    • 2000
  • By DC load flow approximation, we analyzed marginal cost that is the important factor of price signal for network congestion management and expressed as a function of load. In network congestion, a large scale electric network is partitioned into subnetwork to provide a effetive price signal through zonal pricing. We propose a new network partition technique using marginal cost sensitivity with a variety of load consumption.

  • PDF

The shortest path finding algorithm using neural network

  • Hong, Sung-Gi;Ohm, Taeduck;Jeong, Il-Kwon;Lee, Ju-Jang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.434-439
    • /
    • 1994
  • Recently neural networks leave been proposed as new computational tools for solving constrained optimization problems because of its computational power. In this paper, the shortest path finding algorithm is proposed by rising a Hopfield type neural network. In order to design a Hopfield type neural network, an energy function must be defined at first. To obtain this energy function, the concept of a vector-represented network is introduced to describe the connected path. Through computer simulations, it will be shown that the proposed algorithm works very well in many cases. The local minima problem of a Hopfield type neural network is discussed.

  • PDF

Real-time Message Network System for a Humanoid Robot

  • Ahn, Sang-Min;Gong, Jung-Sik;Lee, Bo-Hee;Kim, Jin-Geol;Huh, Uk-Youl
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2296-2300
    • /
    • 2005
  • This paper deals with the real-time message network system by a CAN (controller area network) based on the real-time distributed control scheme to integrate actuators and sensors in a humanoid robot. In order to apply the real-time distributed processing for a humanoid robot, each control unit should have the real-time efficient control method, fast sensing method, fast calculation and real-time valid data exchange method. Moreover, the data from sensors and encoders must be transmitted to the higher level of control units in maximum time limit. This paper describes the real-time message network system design and the performance of the system.

  • PDF

신뢰도 지수를 고려한 계통의 Neural-Tabu 알고리즘을 이용한 최적 전송 경로 결정 (Neural-Tabu algorithm in optimal routing considering reliability indices)

  • 신동준;정현수;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1245-1247
    • /
    • 1999
  • This paper describes the optimal reconfiguration of distribution network. The optimal routing of distribution network should provide electricity to customers with quality, and this paper shows that optimal routing of distribution network can be obtained by Neural-Tabu algorithm while keeping constraints such as line power capacity, voltage drop and reliability indices. The Neural-Tabu algorithm is a Tabu algorithm combined with Neural network to find neighborhood solutions. This paper shows that not only the loss cost but also the reliability cost should be considered in distribution network reconfiguration to achieve the optimal routing.

  • PDF

PICNET Network Configurator for Distributed Control System

  • Kim, Dong-Sung;Lee, Jae-Young;Jun, Tae-Soo;Moon, Hong-Ju;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.100-103
    • /
    • 1999
  • In this paper, a method for the efficient implementation of the PICNET network configurator for a distributed control system(DCS) is proposed. The network configurator is composed of the time parameter estimator and the period scheduler, the file generator. The main role of network configurator estimates time parameter, the pre-run time scheduling of the user input and make the period transmission table for operating the PICNET based distributed control system.

  • PDF

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

Proportional-Fair Downlink Resource Allocation in OFDMA-Based Relay Networks

  • Liu, Chang;Qin, Xiaowei;Zhang, Sihai;Zhou, Wuyang
    • Journal of Communications and Networks
    • /
    • 제13권6호
    • /
    • pp.633-638
    • /
    • 2011
  • In this paper, we consider resource allocation with proportional fairness in the downlink orthogonal frequency division multiple access relay networks, in which relay nodes operate in decode-and-forward mode. A joint optimization problem is formulated for relay selection, subcarrier assignment and power allocation. Since the formulated primal problem is nondeterministic polynomial time-complete, we make continuous relaxation and solve the dual problem by Lagrangian dual decomposition method. A near-optimal solution is obtained using Karush-Kuhn-Tucker conditions. Simulation results show that the proposed algorithm provides superior system throughput and much better fairness among users comparing with a heuristic algorithm.

OMNeT++ 기반 Mobile Ad-hoc Network 라우팅 프로토콜 비교분석 (A Comparative Analysis Of Routing Protocol In Mobile Ad-hoc Network Based On OMNeT++)

  • 김상영;이병준;조영주;윤희용
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2016년도 제53차 동계학술대회논문집 24권1호
    • /
    • pp.63-64
    • /
    • 2016
  • Ad-hoc Network는 노드의 이동성과 제한된 배터리 수명에 의해 Network 토폴로지가 자주 교체되며 이런 연유로 적합한 Routing Protocol을 선택하는 것도 매우 중요한 과제이다. 본 논문에서는 자주 변화하는 Ad-hoc Network에 적합한 Routing Protocol을 선정하기 위해서 OMNeT++을 이용해 시뮬레이션 환경을 설정하고 각 Routing Protocol 특성을 파라미터 화시켜 적용, 요소별 수치를 비교 분석하여 성능평가를 하였다.

  • PDF

비자성체 용기 가열을 위한 Induction Cooker 공진 네트워크 설계 및 검증 (Resonant Network Design and Verification of Induction Cooker for Heating Nonmagnetic Vessel)

  • 장은수;박상민;주동명;이병국
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.504-509
    • /
    • 2017
  • This paper proposes a procedure for designing a resonant network for induction cookers that enables the induction heating of magnetic and non-magnetic vessels. In order to design such network, the range of operating frequency must be determined according to the material of the vessels by measuring several parameters, such as equivalent resistance and inductance, which are reflected in the working coil of the vessels. Through this process, the capacitance of the resonant capacitor is determined. The PSIM simulation and experiment results verify the feasibility of the proposed design and the heating performance of the designed resonant network.