Extended Kalman Filter Approach to Dynamic Electrical Impedance Tomography with Internal Electrodes

  • S.I. Kang;Kim, K.Y.;Kim, H.C.;Kim, M.C.;Kim, S.;Lee, H.J.;Lee, Y.J.;W.C. Cho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.39.1-39
    • /
    • 2001
  • Impedance tomography (EIT) is a relatively new imaging modality in which the internal impedivity distribution is reconstructed based on the known sets of injected currents through the electrodes and induced voltages on the surface of the object. We describe a dynamic EIT imaging technique for the case where the resistivity distribution inside the object changes rapidly within the time taken to acquire a full set of independent measurement data, In doing so, the inverse problem is treated as the nonlinear state estimation problem and the unknown state (resistivity) is estimated with the aid of extended Kalman filter in a minimum mean square error sense. In particular, additional electrodes are attached to the known internal structure of the object ...

  • PDF

디지털 임피던스 영상 시스템의 설계 및 구현 (Design and Implementation of Digital Electrical Impedance Tomography System)

  • 오동인;백상민;이재상;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.269-275
    • /
    • 2004
  • 인체내부의 각 조직은 서로 다른 저항률(resistivity)분포를 가지며, 조직의 생리학적, 기능적 변화에 따라 임피던스가 변화한다. 본 논문에서는 주로 기능적 영상을 위한 임피던스 단층촬영 (EIT, electrical impedance tomography) 시스템의 설계와 구현 결과를 기술한다. EIT 시스템은 인체의 표면에 부착한 전극을 통해 전류를 주입하고 이로 인해 유기되는 전압을 측정하여, 내부 임피던스의 단층영상을 복원하는 기술이다. EIT 시스템의 개발에 있어서는 영상복원의 난해함과 아울러 측정시스템의 낮은 정확도가 기술적인 문제가 되고 있다. 본 논문은 기존 EIT 시스템의 문제점을 파악하고 디지털 기술을 이용하여 보다 정확도가 높고 안정된 시스템을 설계 및 제작하였다. 크기와 주파수 및 파형의 변화 가능한 50KHz의 정현파 전류를 인체에 주입하기 위해 필요한 정밀 정전류원을 설계하여 제작한 결과, 출력 파형의 고조파 왜곡(THD, total harmonic distortion)이 0.0029%이고 진폭 안정도가 0.022%인 전류를 출력 할 수 있었다. 또한, 여러개의 정전류원을 사용함으로써 채 널간 오차를 유발하던 기존의 시스템을 변경하여, 하나의 전류원에서 만들어진 전류를 각 채널로 스위칭하여 공급함으로써 이로 인한 오차를 줄였다. 주입전류에 의해 유기된 전압의 정밀한 측정을 위해 높은 정밀도를 갖는 전압측정기가 필요하므로 차동증폭기, 고속 ADC및 FPGA(field programmable gate array)를 사용한 디지털 위상감응복조기 (phase-sensitive demodulator )를 제작하였다. 이때 병렬 처리를 가능하게 하여 모든 전극 채널에서 동시에 측정을 수행 할 수 있도록 하였으며, 제작된 전압측정기의 SNR(signal-to-noise ratio)은 90dB 이다. 이러한 EIT 시스템을 사용하여 배경의 전해질 용액에 비해 두 배의 저항률을 가지는 물체(바나나)에 대한 기초적인 영상복원 실험을 수행하였다. 본 시스템은 16채널로 제작되었으나 전체를 모듈형으로 설계하여 쉽게 채널의 수를 늘릴 수 있는 장점을 가지고 있어서 향후 64채널 이상의 디지털 EIT시스템을 제작할 계획이며, 인체 내부의 임피던스 분포를 3차원적 으로 영상화하는 연구를 수행 할 예정이다.

조정 확장 칼만 필터를 이용한 동적 전기 임피던스 단층촬영법 (Dynamical Electrical Impedance Tomography Based on the Regularized Extended Kalman Filter)

  • 김경연;김봉석;강숙인;김민찬;이정훈;이윤준
    • 전자공학회논문지SC
    • /
    • 제38권5호
    • /
    • pp.23-32
    • /
    • 2001
  • 전기 임피던스 단층촬영법은 표적의 경계면에서 여러 개의 전극을 통하여 전류를 주입하고 저항률의 함수로써 경계면에 유기되는 전압을 구하고, 경계면에 유기된 전압 값으로부터 표적 내부의 저항률 분포를 추정하여 표적의 영상을 복원하는 비교적 새로운 영상복원법이다. 본 논문에서는, 상태방정식과 측정방정식으로 구성되는 동적 모델에 기초하여, 시간에 따라 변하는 저항률 분포를 온라인으로 추정하기 위해 확장 칼만 필터를 이용한 전기 임피던스 단층촬영법의 영상복원 알고리즘을 제안하였다. 또한, Tikhonov 조정 기법에 근거한 제약조건을 비용함수에 추가하여 역문제의 부정치성을 완화시켰다. 제안된 영상복원 알고리즘의 성능을 검증하기 위해 16 채널에 대한 컴퓨터 시뮬레이션을 수행하였으며, 시간에 따른 표적의 저항률 분포의 변화가 심한 경우에도 비교적 양호한 복원성능을 나타내었다.

  • PDF

내부 전극을 이용한 동적 전기 임피던스 단층촬영법 (Dynamic Electrical Impedance Tomography with Internal Electrodes)

  • 강숙인;김경연
    • 전기전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.153-163
    • /
    • 2001
  • 전기 임피던스 단층촬영법은 물체 표면의 전극을 통하여 전류를 주입하고 유기된 전압을 측정한 후, 물체 단면의 저항을 분포를 복원하는 기법이다. 본 논문에서는, 대상물체의 저항을 값의 분포가 급변하는 상황에 대한 동적 전기저항 단층활영법을 제안하였다. 특히, 복원 성능을 개선하기 위하여 물체 내부의 구조를 전극으로 사용하였으며, 비 선형 역문제를 상태 추정문제로 설정하여 확장 칼만필터를 이용하여 상태변수(저항율)를 추정하였다. 또한 역문제의 부정치성을 완화시키기 위하여 수정된 Tikhonov 조정기법을 비용함수에 도입하였다. 제안된 알고리즘의 성능을 분석하기 위해 컴퓨터 시뮬레이션을 수행했으며, 기존의 방법들에 비해 개선된 결과를 얻었다.

  • PDF

ELECTRICAL IMPEDANCE IMAGING FOR SEARCHING ANOMALIES

  • Ohin Kwon;Seo, Jin-Keun;Woo, Eung-Je;Yoon, Jeong-Rock
    • 대한수학회논문집
    • /
    • 제16권3호
    • /
    • pp.459-485
    • /
    • 2001
  • The aim of EIT (electrical impedance tomography) system is to image cross-section conductivity distribution of a human body by means of both generating and sensing electrodes attached on to the surface of the body, where currents are injected and voltages are measured. EIT has been suffered from the severe ill-posedness which is caused by the inherent low sensitivity of boundary measurements to any changes of internal tissue conductivity values. With a limited set of current-to-voltage data, figuring out full structure of the conductivity distribution could be extremely difficult at present time, so it could be worthwhile to extract some necessary partial information of the internal conductivity. We try to extract some key patterns of current-to-voltage data that furnish some core information on the conductivity distribution such s location and size. This overview provides our recent observation on the location search and the size estimation.

  • PDF

나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법 (Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface)

  • 김태의;김현지;위헌;오동인;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.39-46
    • /
    • 2012
  • Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations, lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원 (Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography)

  • 강숙인;김경연
    • 전기전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.272-281
    • /
    • 2014
  • 전기 임피던스 단층촬영법을 이용한 정적 영상 복원에서 대표적으로 사용되고 있는 복원 알고리즘은 modified Newton-Raphson(mNR) 알고리즘으로 수렴 속도 및 추정 정확도 측면에서 비교적 다른 알고리즘들에 비해 좋은 성능을 나타낸다. mNR 알고리즘에서는 측정 전압과 계산 전압과의 차이, 즉 잔류오차를 최소화하도록 목적함수를 설정하고 이를 반복 연산하여 내부의 저항률 분포를 추정한다. 이때 EIT 역문제의 비정치성을 완화시키기 위해 조정방법을 사용하며 조정인자에 따라 서로 다른 영상 복원 성능을 나타낸다. 기존 기법에서는 반복 연산마다 일정한 상수 값의 조정인자를 사용하기 때문에 대상 물체의 내부 상태가 변하거나 측정 잡음 등이 있는 경우 때때로 조정인자에 따라 영상 복원이 수렴되지 않는다. 따라서 본 논문에서는 영상 복원 수렴 및 성능을 개선하기 위하여 잔류오차에 기반하여 반복 연산마다 자동적으로 조정인자를 수정하는 기법을 제안하였다. 시뮬레이션과 실험을 수행하여 제안된 기법의 영상 복원성능을 평가한 결과 비교적 양호한 성능을 나타내었다.

인접전류패턴을 사용한 변형된 방향 대수적 영상복원법 (Modified Directional Algebraic Reconstruction Technique Using Adjacent Current Pattern)

  • 김지훈;김찬용;김경연;최봉열
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.256-264
    • /
    • 2012
  • 전기 임피던스 단층촬영법(electrical impedance tomography, EIT)에서 관심 대상물 내부 영상을 복원하는 방법 중 하나인 방향 대수적 영상복원법(directional algebraic reconstruction technique, DART)은 삼각함수형태로 설계된 전류패턴을 외부 전극에 인가하고 이로부터 얻어지는 전압과의 상관관계를 이용하여 영상복원 알고리즘의 입력인 각 전극사이의 저항을 유도하게 된다. 이때, 저항유도 시간이 발생하고 이는 DART 알고리즘을 실시간 영상복원에 적용하는데 장애가 되고 있다. 이 논문에서는 저항유도 시간의 문제를 해결하기 위하여 기존에 사용하던 삼각함수형태의 전류패턴대신 인접전류패턴을 사용한 변형된 방향 대수적 영상복원법(modified directional algebraic reconstruction technique, mDART)을 제안한다. 제안한 방법은 주입한 전류와 측정된 전압으로부터 저항을 유도하지 않고 측정전압을 바로 복원 알고리즘의 입력으로 사용하기 때문에 DART의 영상복원시간의 대부분을 차지하는 저항유도 시간을 없앨 수 있을 뿐만 아니라 인접전류패턴을 사용하여 복원영상의 질도 향상시킬 수 있다. 이 논문의 타당성을 입증하기 위하여 모의실험을 수행하였으며 제안한 방법은 기존 방법보다 복원시간의 개선뿐만 아니라 영상오차 관점에서도 성능이 개선됨을 확인하였다.

주입전류 패턴에 따른 EIT 방광 모니터링 시스템의 성능분석 (Performance analysis of EIT bladder monitoring system according to input current patterns)

  • 한유정;;김경연
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.164-172
    • /
    • 2019
  • 현재 배뇨 장애를 진단할 수 있는 대표적인 임상 방법들은 침습적이고 고가이며, 장시간 연속적인 모니터링을 수행하기에는 한계가 있다. EIT는 비침습적 방법으로 외부 전극을 통하여 전류를 주입하고 유기된 전압을 측정하여 내부 전기적(임피던스) 특성을 영상화 하는 기술로써, 저렴한 비용으로 방광의 상태를 모니터링 할 수 있는 유용한 기법이 될 수 있다. 전극을 통하여 주입된 전류 패턴에 따라 측정전압 데이터의 신호특성이 달라지고 영상 복원 성능에 영향을 미친다. 본 논문에서는 인체 하복부 부근에 위치한 방광의 크기 변화에 대한 민감도가 극대화될 수 있는 모델링을 위해 입력전류 패턴에 따른 영상 복원 성능을 분석하였다.

MREIT Conductivity Imaging of Pneumonic Canine Lungs: Preliminary Post-mortem Study

  • Kim, Hyung-Joong;Kim, Young-Tae;Jeong, Woo-Chul;Minhas, Atul S.;Lee, Tae-Hwi;Lim, Chae-Young;Park, Hee-Myung;Kwon, O-Jung;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.94-98
    • /
    • 2010
  • In magnetic resonance electrical impedance tomography (MREIT), a current-injection MR imaging method is adopted to produce a cross-sectional image of an electrical conductivity distribution in addition to MR images. The purpose of this study was to test the feasibility of MREIT for differentiating the canine lung parenchyma without and with pneumonia. Three normal healthy beagles and two mixed breed dogs with pneumonia were used. After attaching electrodes around the chest, we placed the dog inside our MR scanner. We injected as much as 30 mA current in a form of short pulses into the chest region. Reconstructed conductivity images of normal canine lungs exhibit a peculiar pattern of a relatively coarse salt and pepper noise. On the contrary, conductivity images of pneumonic canine lungs show significantly enhanced contrast of the lesions while the corresponding MR images show a little bit of contrast in the middle and caudal lung parenchyma due to the accumulation of pleural fluid. This preliminary study indicates that MREIT imaging of the chest may deliver unique new diagnostic information.