• 제목/요약/키워드: Electrical impedance analysis

검색결과 659건 처리시간 0.026초

구형파를 이용한 전극계면 분석용 고속 임피던스 분석기의 설계변수 확정을 위한 컴퓨터 시뮬레이션 (Computer simulation to determine system parameters of the square-wave adapted fast impedance analyzer for the electrode - electrolyte interface analysis)

  • 김기련;김광년;심윤보;전계록;정동근
    • 한국시뮬레이션학회논문지
    • /
    • 제14권2호
    • /
    • pp.45-55
    • /
    • 2005
  • There are electric double layer capacitance, polarization resistance and solution resistance in the interface between electrode and solution. Electrode process could be evaluated by the electrical impedance analysis. The necessities of the electrochemical cell analysis with high speed impedance analyzer are followings: minimization of the effects of electric stimulation on electrochemical cell and the concentration of reactive materials, and optimization of impedance signal resolution. This paper represents the design criteria for the selection and stimulation to develop fast impedance analyzer prototype for a electrochemical cell. It was suggested that the design of 470k sample/s sampling rate, 13 bit ABC resolution, and 140ms recording time is required for high speed impedance analysis system in frequency range between dc and 10kHz.

  • PDF

변전소와 차량간의 동기화를 통한 실시간 전차선로 임피던스 예측 기법 연구 (A Study on Real Time Catenary Impedance Estimation Technique using the Synchronized Measuring Data between Substation and Train)

  • 정호성
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1458-1464
    • /
    • 2013
  • This paper proposed a new real time catenary impedance estimation technique using synchronized power data from the measured data of operating vehicle and substation for catenary protective relay and fault locator setting. This paper presented estimation equation of catenary impedance using synchronized power data between substation and vehicle of AT feeding system for the performance verification of the proposed technique. Also AC feeding system is modeled through power analysis program and performance was verified through simulation according to various load changes. We verified that average 2.38%(distance equivalent 23.8 m) error appeared between the proposed estimation equation of catenary impedance and power analysis program simulation output in no connection double track system between up track and down track. Furthermore, We confirmed that estimation error is bigger depending on the increasing the distance from substation and vehicle impedance using only using vehicle current when calculating vehicle impedance in connection double track system between up track and down track. But, We confirmed that the proposed technique estimated accurately catenary impedance regardless of vehicle impedance and distance from substation.

조립과정이 스피커의 전기 및 음향특성에 미치는 영향 (Effects of Electrical and Acoustical Variations for Loudspeaker due to Fabrication Processes)

  • 박석태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.155-159
    • /
    • 2004
  • In this paper, it was analyzed the characteristics of electrical and acoustical variations for loudspeaker due to fabrication processes. First, mass of each components of loudspeaker was measured by electric precision scale and performed statistical analysis. Second. Thiele-Small parameters of sample loudspeakers produced by unskilled students were identified by known mass parameter identification method using electrical impedance method and investigated on the variations of each parameter. Electrical impedance tests and acoustic frequency responses were measured on sample loudspeakers and variations were examined to grasp relationship between components variation and fabrication processes. Main factors to effect the changes of electrical impedance were concluded by fabrication processes errors not by components of loudspeaker.

  • PDF

Structural and electrical properties of lead free ceramic: Ba(Nd1/2Nb1/2)O3

  • Nath, K. Amar;Prasad, K.;Chandra, K.P.;Kulkarni, A.R.
    • Advances in materials Research
    • /
    • 제2권2호
    • /
    • pp.119-131
    • /
    • 2013
  • Impedance and electrical conduction studies of $Ba(Nd_{1/2}Nb_{1/2})O_3$ ceramic prepared using conventional high temperature solid-state reaction technique are presented. The crystal symmetry, space group and unit cell dimensions were estimated using Rietveld analysis. X-ray diffraction analysis indicated the formation of a single-phase cubic structure with space group $Pm\bar{3}m$. Energy dispersive X-ray analysis and scanning electron microscopy studies were carried to study the quality and purity of compound. The circuit model fittings were carried out using the impedance data to find the correlation between the response of real system and idealized model electrical circuit. Complex impedance analyses suggested the dielectric relaxation to be of non-Debye type and negative temperature coefficient of resistance character. The correlated barrier hopping model was employed to successfully explain the mechanism of charge transport in $Ba(Nd_{1/2}Nb_{1/2})O_3$. The ac conductivity data were used to evaluate the density of states at Fermi level, minimum hopping length and apparent activation energy.

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.

배전계통에 사용되는 봉형 접지전극의 접지 특성 분석 (Grounding Characteristics Analysis of the Rod-Type Grounding Electrodes used for Electric Distribution Systems)

  • 김경철;정지원
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.49-56
    • /
    • 2011
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the copper and concrete rod grounding electrodes. An equivalent transfer function model of the ground impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing the conventional grounding impedance.

Simplified Impedance Modeling and Analysis for Inter-Turn Fault of IPM-type BLDC motor

  • Kim, Byeong-Woo;Kim, Kyung-Tae;Hur, Jin
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.10-18
    • /
    • 2012
  • This paper proposes a finite element method (FEM)-based model of an interior permanent magnet (IPM)-type BLDC motor having stator inter-turn faults. We also propose impedance modeling of the magnetic characteristics. By integrating the developed model with a current-controlled voltage source inverter (CCVSI) model, the distributed characteristics of an inter-turn fault operated by a six-switch inverter are investigated considering speed control. Moreover, this paper presents the flux density distribution and torque characteristics for analyzing the inter-turn fault of an IPM-type BLDC motor. Additionally, fault impedance is required to calculate the circulating current that causes magnetic distortion. Thus, this paper proposes a method for estimating the circulating current taking into account the voltage at the shorted turn and the rotating speed. The analysis data were verified experimentally.

Impedance spectroscopy analysis of the $Li_2CO3$ doped $(Ba,Sr)TiO_3$ thick films

  • 함용수;고중혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.27-28
    • /
    • 2009
  • In this study, we have fabricated the 3 wt% $Li_2CO3$ doped $(Ba,Sr)TiO_3$ thick films on the Ag/Pd printed $Al_2O_3$ substrates for the LTCCs (Low Temperature Co-fired Ceramics) applications. From the X-ray diffraion analysis, 3 wt% $Li_2CO3$ doped BST thick films on the Ag/Pd printed $Al_2O_3$ substrates, which sintered at 900 $^{\circ}C$ have perovskite structure without any pyro phase. The dielectric properties of 3 wt% $Li_2CO3$ doped BST thick films were measured from 1 kHz to 1 MHz. To investigate the electrical properties of 3 wt% $Li_2CO3$ doped BST thick films, we employed the impedance spectroscopy. The complex impedance of 3 wt% $Li_2CO3$ doped BST thick films were measured from 20 Hz to 1 MHz at the various temperatures.

  • PDF

비선형 부하 이차 고조파 발생 실증사례 분석 및 임피던스 변동 기법을 통한 이차 고조파 저감 기법 (Case Study of Second Harmonic Generation under Nonlinear Load and Second Harmonic Elimination Method Based on Impedance Variation Scheme)

  • 방희균;김시경
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.604-611
    • /
    • 2013
  • This paper presents an second harmonic elimination method based on the impedance variation scheme. Through the power quality analysis from the nonlinear loads connected on the power system, the second harmonic problems have been analyzed with a case study analysis and the experiments. In the paper, the second Harmonic generation was simulated with a single phase SCR rectifier and the analytical model is proposed for the second harmonic generation. A novel impedance variation scheme is proposed and analyzed to eliminate the second harmonic. The experiment has been performed on the 60(MVA) industry manufacturing plant. The experimental result demonstrates the proposed impedance variation scheme successfully operate on the 60(MVA) industry manufacturing plant.

지중케이블 선로 임피던스 실측 및 분석 (Measurement and Analysis of Line Impedance in Underground Cables)

  • 하체웅;김정년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.205-207
    • /
    • 2003
  • The line impedance is important data that is applied in all analysis fields of electric power system like power flow, fault current, stability and relay calculation etc. Usually, impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistance. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Therefore, the line impedance were measured for this study in an actual power system of underground cables, and were analyzed by a generalized circuit analysis program EMTP for comparison with the measured value. These analysis result is considered to become foundation of impedance calculation for underground cable.

  • PDF