• Title/Summary/Keyword: Electrical fire prevention

Search Result 140, Processing Time 0.029 seconds

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Systematic Measure of The Safety Accidents 'Preparation Behavior Manual' in Campground (캠핑장 안전사고 '대비 행동 매뉴얼'의 체계화 방안)

  • Yi, Joo-Wook;Kim, Yun-Sang;Han, Dong-Soo
    • Journal of Digital Convergence
    • /
    • v.16 no.2
    • /
    • pp.441-449
    • /
    • 2018
  • This study is to organize the manual for the safety accidents in campsite. For this, analyzing the types of safety accidents and reviewing the regulations of campsite. Through theoretical considerations, the problem was diagnosed and the elements of improvement were presented. Eventually, part of the Responsive and Preventative Behavior manuals were developed to organize 'Preparation Behavior Manual'. Especially, examples of safety accident prevention behavior manual were divided into: 1st, suffocation, 2nd, traffic accident, 3rd, fire, 4th, and electrical accident. "S.A.F.E.", An example, was created with the accident specific initials that were more frequently caused. Furthermore, it was emphasized that it is necessary to process of understood by the user. Subsequent studies recommended the study of cases, improvement of safety management indicators, and the specialization of campground manager and safety guard.

Illumination simulation for selective application and energy saving of solar cells in single-span glass greenhouse (단동식 유리온실에서 태양전지의 선별적 적용과 에너지 절감에 관한 조도 시뮬레이션)

  • Jung, Hai-Young;Lee, Boong-Joo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1448-1456
    • /
    • 2019
  • In this study, when applying LED light sources within a single-span glass greenhouse for growing crops, the illumination simulation was performed on the ceiling and side of the glass greenhouse to determine the selective placement and effective light transmission of Si series solar cells and dye-sensitive solar cells (DSSC) for supplying LED power source. In addition, energy saving effects of glass greenhouses were analyzed for optimum lighting control when both daylight and LED light sources are considered in glass greenhouses.

Development of the Standard Model of a Stated Period Check and Precise Safety Diagnosis in the Research Lab for Prevention to Electrical Accidents (전기사고방지를 위한 연구실험실 정기점검/정밀안전진단 표준모델개발)

  • Lee, Dong-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2011
  • There is no standard model for a Stated Period Check and a Precise Safety Diagnosis to remove electric fire and shock in the university Lab and institute. Especially, the research for the Stated Period Check and the Precise Safety Diagnosis of the Lab related to electrical field is very weak currently, and it is very necessary to build a detail safety plan. This paper informs the specific standard guideline of the safety check list, method and equipment and it shows the way to evaluate safety grade too. This paper also provides the information of R&D process through the analysis of electrical safety check list of ordinary R&D Lab. It shows a new detail guideline to R&D Lab, and the new guideline removes existing problem and deliver the effective standard model to each R&D Lab. The standard model developed in this research adopts the clear guideline of each check list for the electrical environment of current R&D Lab. This standard model can be applied for every R&D Lab to detect routine safety check and detail safety check immediately. This Research will generally improve not only the effective safety check, but also the safety level for R&D Lab to prevent the electrical accidents.

Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.

Gas Sensing Characteristics of $SnO_{2}$ added with $TiO_{2},\;Pd,\;Pt$ and in for Trimethylamine Gas (Trimethylamine Gas 측정을 위한 $TiO_{2},\;Pd,\;Pt$ 및 In이 첨가된 $SnO_{2}$가스 센서의 특성)

  • Lee, Chang-Seop;Jung, Soon-Boon;Jun, Jae-Mok;Lee, In-Sun;Lee, Hyeong-Rag;Park, Young-Ho;Choi, Sung-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.29-33
    • /
    • 2007
  • This study investigates the use of $TiO_{2},\;Pd,\;Pt$, and In which greatly improves a sensitivity to trimethylamine gas. The metal-$SnO_{2}$ thick films were prepared by screen-printing method onto $Al_{2}O_{3}$ substrates with platinum electrode. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box as a function of detecting gas concentration. This was then used to detect trimethylamine, dimethylamine, and ammonia vapours within the concentration range of 100-1000ppm. The gas sensing properties of metal-$SnO_{2}$ mixed thick films depended on the content and variety of metal. It was found that sensitivity and selectivity of the films dopped with 1 wt% Pd and 10 wt% $TiO_{2}$ for trimethylamin gas showed the best result at $250^{\circ}C$.

  • PDF

Development of Intelligent Outlets for Real-Time Small Power Monitoring and Remote Control (실시간 소전력 감시 및 원격제어용 지능형 콘센트 개발)

  • Kyung-Jin Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.169-174
    • /
    • 2023
  • Currently, overall power usage is also increasing as power demand such as homes, offices, and factories increases. The increase in power use also raised interest in standby power as a change in awareness of energy saving appeared. Home and office devices are consuming power even in standby conditions. Accordingly, there is a growing need to reduce standby power, and it aims to have standby power of 1W or less. An intelligent outlet uses a near-field wireless network to connect to a home network and cut or reduce standby power of a lamp or appliance connected to an outlet. This research aims to develop a monitoring system and an intelligent outlet that can remotely monitor the amount of electricity used in a lighting lamp or a home appliance connected to an outlet using a short-range wireless network (Zigbee). Also, The intelligent outlet and monitoring system developed makes it possible for a user to easily cut off standby power by using a portable device. Intelligent outlets will not only reduce standby power but also be applicable to fire prevention systems. Devices that cut off standby power include intelligent outlets and standby power cutoff switches, so they will prevent short circuits and fires.