• 제목/요약/키워드: Electrical equipment

검색결과 2,795건 처리시간 0.029초

공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구 (The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure)

  • 김기현;이상익;배석명;정찬웅;이재용
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

유입식 변압기의 상태진단을 통한 노후도 평가 방법 (A Study on Deterioration Evaluation Method by Condition Monitoring and Diagnosis for Aging Oil-immersed Power Transformers)

  • 장정호;이성훈;이흥호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.297-305
    • /
    • 2014
  • Nowadays new water supply projects have been on the decline as the water-power constructions have saturated, which means that the existing power equipment have slowly aged and they require more efforts to maintain the system performance. An effective asset management method of power equipment has become a great necessity from both economical and technical aspects. To be balanced, the asset management should look into all three parts: management, engineering, and information. The purpose of this paper is to study a Risk-Based Maintenance (RBM) matrix method through the deterioration evaluation algorithm for an efficient reliability assessment of oil-immersed power transformers by considering both asset management and technical evaluation. Make use of this result, the equipment will be decided to be replace or repair otherwise on service.

Theoretical study on electrical behavior of carbon chain inserted single-walled carbon nanotubes compared with Pt doped one

  • Cui, Hao;Zhang, Xiaoxing;Xiao, Hanyan;Tang, Ju
    • Carbon letters
    • /
    • 제25권
    • /
    • pp.55-59
    • /
    • 2018
  • Carbon chain inserted carbon nanotubes (CNTs) have been experimentally proven having undergone pronounced property change in terms of electrical conductivity compared with pure CNTs. This paper simulates the geometry of carbon chain inserted CNTs and analyzes the mechanism for conductivity change after insertion of carbon chain. The geometric simulation of Pt doped CNT was also implemented for comparison with the inserted one. The results indicate that both modification by Pt atom on the surface of CNT and addition of carbon chain in the channel of the tube are effective methods for transforming the electrical properties of the CNT, leading to the redistribution of electron and thereby causing the conductivity change in obtained configurations. All the calculations were obtained based on density functional theory method.

특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구 (A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle)

  • 이상건;김성안;조윤현
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

도시철도 전력설비 상태감시 시스템 구성 (Condition Monitoring System Construction for Electrical Equipments of Metropolitan Rapid Transit)

  • 박현수;최광범;어수영;유기선;임형길;정호성;박영;고성범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.447-451
    • /
    • 2009
  • Metropolitan rapid transit has been used by one of a main transport service for several decades, but there are no monitoring system for electrical equipment condition which can cause enormous economic loss and social problem if fault occurs. Recently, necessity of condition monitoring system for electrical equipment fault came to the fore, we became carrying out a research project for a design of electrical equipment lifetime estimation system for metropolitan rapid transit. In this paper, basic design result of condition monitoring system and specification of transformer partial discharge detection system are presented, which are part of entire lifetime estimation system. Definition of target apparatus and monitoring method determined by analysis of user requirement from each railway company and, each railway company's opinions and requests were collected sufficiently by surveys and discussion.

  • PDF

고속철도 귀선전류 및 차축 온도 검측을 위한 검측장치 구현 (Implementation of the Measurement Equipment to Measure Return Current and Axle Temperature of High Speed Railway)

  • 이영수;이병곤;황인광;한승훈
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.695-703
    • /
    • 2016
  • The maintenance method for the electrical facility of high speed railway has been evolved from inspection by personnel to the automated way by the detection devices. In particular, the signalling equipment in order to increase the safe and efficient operation of the trains is required to maintain normal operation by periodic maintenance. Because the return current gives the most important effects to the wayside equipment in case of the failures, a method is needed to measure the unbalanced rate of return current on the train at high speed driving. The Hot Box Detector(HBD) device that is installed at track-side has a function to recognize the abnormal axle box by detecting the temperature that occurs in the axle of train passing over its device. In order to implement the measurement equipment for unbalanced rate of return current and axle temperature, the design method is proposed and the experimental test results by test bed are included in the paper.

Investigation of Relation between EFTB Test and RF Conductive Immunity Test Using BER and Baseband Signal

  • Kuwabara, Nobuo;Irie, Yasuhiro;Hirasawa, Norihito;Akiyama, Yoshiharu
    • Journal of electromagnetic engineering and science
    • /
    • 제11권4호
    • /
    • pp.274-281
    • /
    • 2011
  • High-speed telecommunication systems are influenced by electromagnetic environments because they need a wide bandwidth to transmit signals. Immunity tests of telecommunication equipment are effective for improving its immunity to electromagnetic environments. However, immunity tests are expensive to carry out because there are several different tests. The correlation among the tests should therefore be examined in order to reduce the kinds of tests that are necessary. This paper investigates the correlation between the electrical fast transient/burst (EFTB) test and the radio frequency (RF) conductive immunity test. Imitation equipment was constructed with a balun, and a baseband signal was transmitted from the associated equipment to the imitation equipment. Then, disturbances were applied to the equipment, and the telecommunication quality was evaluated by using the bit error rate (BER). The results from the EFTB test indicated that the BER was less than $6{\times}10^{-5}$ and the value was independent of the peak value. The results from the RF conductive immunity test indicated that the BER was affected by the longitudinal conversion loss (LCL).

Making Decision of the Maintenance Priority of Power Distribution System using Time Varying Failure Rate and Interruption Cost

  • Chu, Cheol-Min;Kim, Jae-Chul;Yun, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.43-48
    • /
    • 2009
  • The purpose of the this paper is to make decision of the maintenance priority of power distribution system using Time-Varying Failure Rate(TVFR) with interruption cost. This paper emphasizes the practical use of the reliability indices and interruption cost. To make a decision of maintenance priority on power distribution system equipment, the quantification of the reliability level should be represented as a cost. In this paper, the TVFR of power distribution system equipment applied in this paper utilizes analytic method to use the historical data of KEPCO. From this result, the sensitivity analysis on TVFR of equipment was done for the priority, which represents that high priority of the equipment has more effect on system reliability, such as SAIDI or SAIFI, than other equipment. By this priority, the investment plan is established. In this result, customer interruption cost(CIC) could be extracted, and CIC is used as weighting factor to consider a importance of customer. After that, the result calculated the proposal method in this paper is compared with other priority method, such as lifetime, failure rate or only sensitivity.

전기철도용 축소형 전력품질 보상설비에 대한 모델링 및 시뮬레이션 (A modeling and simulation for a Small-Scaled Power Quality Compensating Equipment of Electrical Railway)

  • 강문호;김주락;한문섭
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.96-102
    • /
    • 2007
  • This paper presents a study on the control of a power quality compensating equipment of electrical railway built in small-scaled to preliminary research. Because this compensating equipment is very complicated power electronics system, consisting of a scott transformer as a power source, four single phase inverters interconnected with DC-link capacitors and various electrical apparatuses, multiple controllers and control algorithms with high performance and reliability are needed. The major function of the compensating equipment is to manage reactive and active powers by using the four single phase inverters, so, the main control effort is focused on the power flow control which realized through the decoupling current control of the four inverters. Overall control system is designed with object oriented and analyzed on a Simulink window. The simulation results show that the design scheme is very effective for a complicated control system and the proposed controller has good performance.

A Fast-Transient Repetitive Control Strategy for Programmable Harmonic Current Source

  • Lei, Wanjun;Nie, Cheng;Chen, Mingfeng;Wang, Huajia;Wang, Yue
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.172-180
    • /
    • 2017
  • The repetitive control (RC) strategy is widely used in AC power systems because of its high performance in tracking period signal and suppressing steady-state error. However, the dynamic response of RC is determined by the fundamental period delay $T_0$ existing in the internal model. In the current study, a ($nk{\pm}i$)-order harmonic RC structure is proposed to improve dynamic performance. The proposed structure has less data memory and can improve the tracking speed by n/2 times. $T_0$ proves the effectiveness of the ($nk{\pm}i$)-order RC strategy. The simulation and experiments of ($6k{\pm}1$)-order and ($4k{\pm}1$)-order RC strategy used in the voltage source inverter is conducted in this study to control the harmonic current source, which shows the validity and advantages of the proposed structure.