• Title/Summary/Keyword: Electrical equipment

Search Result 2,795, Processing Time 0.027 seconds

Development of automatic yield-test equipment for the Micromirror Array (Micromirror Array의 Yield 측정을 위한 방법 개발)

  • Cho, Kwang-Woo;Kim, Ho-Seong;Shin, Hyung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2547-2549
    • /
    • 1998
  • Automatic yield-test equipment for micro mirror array using image processing was developed. This computerized test equipment can classify the error states of the micromirrors. The test results are displayed on the monitor as a map which shows the error states and position. It is possible to measure yield and reliability with this test equipment for micromirror array using image processing.

  • PDF

Development of a 3-D Visualization Application for Management of Substation Equipment

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.38-44
    • /
    • 2009
  • This paper presents a new windows application based on 3-D graphics and Text-To-Speech (TTS) for effective management of substation equipment. When problems in a power system occur, inexperienced power system operators may have difficulty in understanding the situation as well as finding suitable countermeasures quickly. This paper addresses an effective scheme to visualizing power system equipment under normal and abnormal conditions using 3-D graphics and animations. In addition, the state variations and the order of maintenance priority of substation equipment are represented by TTS and intuitive methods. The proposed system can help power system operators to more quickly understand the state of power system equipment, and it can provide operators with the suitable countermeasures for minimizing damage caused by equipment problems.

Protecting of Electrical Equipment Faults Caused by Magpie (까치에 의한 전력설비 피해방지 대책)

  • Bang, J.S.;Lee, J.S.;Park, Y.K.;Lim, K.J.;Jeong, K.H.;Choi, S.C.;Sin, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1663-1665
    • /
    • 1998
  • The power distribution system is 22.9 kV-y neutral point multi-ground one in our country. So, if conducting materials contacted, to the power line electrical equipment faults or stoppage of electrical power supply happened in the line. contacts are caused by magpie or its nest materials, especially, electrical power incidents by magpie from February to May, season layed egg, is high as 30% as. It is important to electrical power supplier to protect electrical power equipment caused by magpie. From now, KEPCO have tried to protect electrical power equipment faults caused by magpie using several methods, but have not acquired good results and continued to withdraw the nest. Recently, nature environment protection expand to around country and KEPCO also changed the nest withdrawal method to new pre-protection method coexisted with magpie, "Environmental Affinitive Pre-protection Counterplan". Therefore, we planned environmental affinitive pre-protection equipment, set test line. Also, after analyzed its effects during 1 year, we satisfied with results, and then expanded to other test lines and regions.

  • PDF

Generalized Reliability Centered Maintenance Modeling Through Modified Semi-Markov Chain in Power System

  • Park, Geun-Pyo;Heo, Jae-Haeng;Lee, Sang-Seung;Yoon, Yong-Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • The purpose of power system maintenance is to prevent equipment failure. The maintenance strategy should be designed to balance costs and benefits because frequent maintenance increases cost while infrequent maintenance can also be costly due to electricity outages. This paper proposes maintenance modeling of a power distribution system using reliability centered maintenance (RCM). The proposed method includes comprehensive equipment modeling and impact analysis to evaluate the effect of equipment faults. The problem of finding the optimum maintenance strategy is formulated in terms of dynamic programming. The applied power system is based on the RBTS Bus 2 model, and the results demonstrate the potential for designing a maintenance strategy using the proposed model.

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.1
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.

The Development of Monitoring System in the Scrubber of Semiconductor Manufacture Processing (반도체 공정의 SCRUBBER 감시 시스템 개발)

  • Kim, Joohn-Hwan;Kim, Sang-Woo;Kim, Beung-Jin;Moon, Hak-Yong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2390-2392
    • /
    • 1998
  • In this paper, we discuss the development of monitoring system with data process equipment which transfers data from Remote Terminal Unit(RTU) to monitoring computer. The RTUs sense temperature, pressure and PLC(Programmable Logic Controller) nodes conditions of scrubber in semiconductor manufacture processing. The data Process equipment is connected every RTU and a monitoring computer through serial communication. This equipment receives informations from RTU, process data, and transfers them to monitoring computer. To avoid congestion in data communication, task scheduling algorithm used RT O/S(Real-Time Operating System) is embedded in ROM which is a part of data Process equipment.

  • PDF

Pressure Contact Interconnection for High Reliability Medium Power Integrated Power Electronic Modules

  • Yang, Xu;Chen, Wenjie;He, Xiaoyu;Zeng, Xiangjun;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.544-552
    • /
    • 2009
  • This paper presents a novel spring pressure contact interconnect technique for medium power integrated power electronics modules (IPEMs). The key technology of this interconnection is a spring which is made from Be-Cu alloy. By means of the string pressure contact, sufficient press-contact force and good electrical interconnection can be achieved. Another important advantage is that the spring exhibits excellent performance in enduring thermo-mechanical stress. In terms of manufacture procedure, it is also comparatively simple. A 4 kW half-bridge power inverter module is fabricated to demonstrate the performance of the proposed pressure contact technique. Electrical, thermal and mechanical test results of the packaged device are reported. The results of both the simulation and experiment have proven that a good performance can be achieved by the proposed pressure contact technique for the medium power IPEMs.

On-line Monitoring and Diagnostics for Distribution Panel System (배전반 시스템의 온라인 감시 및 진단)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.106-110
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Test equipment of traction motor for electric train (전기철도 차량용 견인전동기 시험설비)

  • Jang, Dong-Uk;Park, Hyun-June;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1103-1104
    • /
    • 2006
  • This paper is described about the test equipment of fraction motor for electric train. This test equipment was able to perform the performance test of traction motor which was operated in Korea. We explain performance and function of test equipment. In order to check the performance of test equipment, we conducted the performance test with 200 kW and 1100 kW traction motor.

  • PDF

A study on optimizing the electrical load analysis for modifying the avionics equipment in an aged aircraft

  • Yoon, Inbok;An, Kyeongsoo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.47-56
    • /
    • 2021
  • In the management of aged aircraft, used avionics equipment is replaced with new ones to improve the performance and extend the life cycle of the aircraft. In this case, considering airworthiness, it is necessary to check whether the aircraft has sufficient electricity in the electric generator or the electrical distribution system, in accordance with the maximum electricity consumption of the new avionics equipment. Accordingly, this paper reviews a few airworthiness standards and guidelines associated with the electrical load analysis when an avionics equipment is upgraded in an aged aircraft, and proposes an optimization method for the electrical load analysis. In addition, it verifies the validity of the proposed method via the QFD theory, and is currently available for upgrading the performance of aged aircraft.