• 제목/요약/키워드: Electrical diagnosis

검색결과 1,701건 처리시간 0.022초

변압기 절연열화진단 시스템개발에 관한 고찰 (Study on Development of Insulation Degradation Diagnosis System for Electrical Transformer)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.139-144
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

선형보간법을 이용한 매립형 영구자석 동기모터의 감자고장진단 (Demagnetization Fault Diagnosis in IPMSM Using Linear Interpolation)

  • 정혜윤;문석배;이호진;김상우
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.568-574
    • /
    • 2017
  • This paper proposes a demagnetization fault diagnosis method for interior permanent magnet synchronous motors(IPMSMs). In particular, a demagnetization fault is one of the most frequent electrical faults in IPMSMs. This paper proposes an estimation method for permanent magnet flux. The method is based on linear interpolation. The effectiveness of the proposed method for diagnose demagnetization faults is verified through various operating conditions by finite element simulation.

5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법 (Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System)

  • 백승구;신혜웅;강성윤;박춘수;이교범
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

주상변압기 열화진단장치 개발에 관한 연구 (A study on the development of diagnosis device for pole transformer deterior)

  • 이보호;김재철;김영춘;김훈;민경래;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1079-1081
    • /
    • 1998
  • This paper describes the dissipation factor measuring device for insulating oil in operating pole transformer by DSP(digital signal processor). After applying voltage to the sensor which is installed in a transformer, acquire source voltage and current of sensor using FFT techniques, then we could evaluate the dissipation factor of insulating oil. To improve measuring accuracy and processing speed, we use TMS320C31 DSP, FFT and data analysis techniques. Also we suggest deterioration criterion of insulating oil and compared the developed diagnosis device with schering bridge on deteriorated insulating oil. The result of this paper show that the developed measuring device can be used as diagnosis device for the pole transformers.

  • PDF

On-line Faults Signature Monitoring Tool for Induction Motor Diagnosis

  • Medoued, Ammar;Lebaroud, Abdesselem;Boukadoum, Ahcene;Clerc, Guy
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.140-145
    • /
    • 2010
  • The monitoring and the diagnosis of the faults in induction motors starting from the stator current are very interesting, since it is an accessible and measurable quantity. The spectral analysis of the stator current makes it possible to highlight the characteristic frequencies of the faults but in a wide frequency range depending on half the sampling frequency, making it very difficult to monitor on-line the faults. In order to facilitate the use of the relevant frequencies of machine faults we proposed the extraction of the frequency components using two methods, namely, the amplitude and the instantaneous frequency. The theoretical bases of these methods were presented and the results were validated on a test bench with an induction motor of 5.5 kw.

적외선 열화상 카메라를 이용한 퍼지추론 기반 열화진단 시스템 개발 (Development of Fuzzy Inference-based Deterioration Diagnosis System Using Infrared Thermal Imaging Camera)

  • 최우용;김종범;오성권;김영일
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.912-921
    • /
    • 2015
  • In this paper, we introduce fuzzy inference-based real-time deterioration diagnosis system with the aid of infrared thermal imaging camera. In the proposed system, the infrared thermal imaging camera monitors diagnostic field in real time and then checks state of deterioration at the same time. Temperature and variation of temperature obtained from the infrared thermal imaging camera variation are used as input variables. In addition to perform more efficient diagnosis, fuzzy inference algorithm is applied to the proposed system, and fuzzy rule is defined by If-then form and is expressed as lookup-table. While triangular membership function is used to estimate fuzzy set of input variables, that of output variable has singleton membership function. At last, state of deterioration in the present is determined based on output obtained through defuzzification. Experimental data acquired from deterioration generator and electric machinery are used in order to evaluate performance of the proposed system. And simulator is realized in order to confirm real-time state of diagnostic field

LabVIEW를 이용한 유도전동기 고정자 권선 고장진단시스템 (Stator winding faults diagnosis system of induction motor using LabVIEW)

  • 송명현;박규남;이태훈;한동기;박경한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2658-2660
    • /
    • 2005
  • This paper presents a stator winding fault diagnosis technique of induction motor on the PC - based virtual instrumentation system designed using the graphical programming language LabVIEW. This method collects the 3-phase current signals using the current probe amplifier and PXI/DAQ system then the preprocessing removes the noise using LPF, after then this method transforms the stator current to Park's vector and obtains the each Park's Vector pattern and detects stator winding fault by comparing the obtained faulted pattern with the healthy pattern. This proposed LabVIEW based diagnosis system is applied to the 3 phase 1 hp induction motor and obtained the reasonable results under no load condition. The test results give us the possibility a simple and realistic on-line winding fault diagnosis system.

  • PDF

Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters

  • Kim, Hyung-Seop;Im, Won-Sang;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.384-390
    • /
    • 2012
  • This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3-phase AC/DC pulse width modulation (PWM) converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the 3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and experiments.

Intelligent Diagnosis of Broken Bars in Induction Motors Based on New Features in Vibration Spectrum

  • Sadoughi, Alireza;Ebrahimi, Mohammad;Moallem, Mehdi;Sadri, Saeid
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.228-238
    • /
    • 2008
  • Many induction motor broken bar diagnosis methods are based on evaluating special components in machine signals spectrums. Current, power, flux, etc are among these signals. Frequencies related to a broken rotor fault are slip dependent, therefore, correct diagnosis of fault - especially when obtrusive frequency components are present - depends on accurate determination of motor velocity and slip. The traditional methods typically require several sensors that should be pre-installed in some cases. This paper presents a diagnosis method based on only a vibration sensor. Motor velocity oscillation due to a broken rotor causes frequency components at twice slip frequency difference around speed frequency in vibration spectrum. Speed frequency and its harmonics as well as twice supply frequency, can easily and accurately be found in a vibration spectrum, therefore th motor slip can be computed. Now components related to rotor fault can be found. It is shown that a trained neural network - as a substitute for an expert person - can easily categorize the existence and the severity of a fault according to the features extracted from the presented method. This method requires no information about th motor internal and has been able to diagnose correctly in all the laboratory tests.

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.