• 제목/요약/키워드: Electrical breakdown characteristics

검색결과 1,008건 처리시간 0.028초

유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of $20\sim100[^{\circ}C]$, we are made researches AC breakdown in the gap of $500\sim2500[{\mu}m]$. The classification for the physical properties of oil for oil-immersed transformer by FTIR and H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

반도전층을 갖는 MDPE의 운전 및 절연파괴 특성 (Dielectric and Breakdown Characteristics of MDPE included Semiconductor layer)

  • 유성수;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1633-1635
    • /
    • 1999
  • In this study, we evaluated the dependence of thickness and temperature in the breakdown strength of MDPE and effect of semiconductor. As the result, breakdown strength trend to decrease according to the increase of thickness and temperature. We obtained the result that the breakdown strength was a little lower in the structure of Semi/MDPE than Semi/MDPE/Semi, but breakdown strength of MDPE was greater both of all. The dependency of permittivity, tan ${\delta}$ and conductance on frequency and temperature were investigated. Both of the specimans showed the trend of decreased in permittivity as the temperature increased but increase as the frequency increased.

  • PDF

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

1,200 V Reverse Conducting IGBT의 전기적 특성 분석 (Electrical Characteristics of 1,200 V Reverse Conducting-IGBT)

  • 김세영;안병섭;강이구
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.177-180
    • /
    • 2020
  • This paper focuses on the 1,200-V level reverse conducting-insulated gate bipolar transistor (RC-IGBT). The structure of the RC-IGBT has an n+ collector at the collector terminal. The breakdown voltage, Vth, Vce-sat, and turn-off time, and the electrical characteristics of a field-stop IGBT (FS-IGBT) and RC-IGBT are compared and analyzed using simulations. Based on the results, the RC-IGBT obtained a turn-off time of 320.6 ㎲ and a breakdown voltage of 1,720 V, while the FS-IGBT obtained a turn-off time of 742.2 ㎲ and a breakdown voltage of 1,440 V. Therefore, RC-IGBTs have faster on/off transitions and a higher breakdown voltage, which can reduce the size of the element.

평등/불평등 전계하에서 제조공기(I-Air)와 $SF_6$에 대한 압력별 절연파괴특성 (Breakdown Characteristics for Imitation Air and $SF_6$ with Pressure Variation under Uniform and Non-Uniform Field)

  • 이창욱;이창훈;최은혁;장승호;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using uniform(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage($V_B$) by each P different d.

  • PDF

불평등 전계하의 제조공기(I-Air)에 대한 절연파괴 특성 (Breakdown Characteristics of Imitation Air under Non-Uniform Fields)

  • 이창욱;이창훈;최은혁;윤대희;장승호;김정배;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.385-388
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using non-uniform fields(Needle--Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

온도변화에 따른 $SF_6$와 I-Air의 절연파괴특성 비교 (A Comparision of the Breakdown Characteristics for $SF_6$ and I-Air based on Temperature variations)

  • 박혜리;김도석;이상호;우성훈;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.235-237
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of l-Air(Imitation Air, $N_2:O_2=79:21$) and $SF_6$ gas based on temperature variations in experimental GIS model by applying negative DC voltage. The breakdown charcteristics were compared with gas pressures and each gas already entered in GIS model. The characteristics of l-Air and $SF_6$ were different in specific temperature range that $SF_6$ gas was being liquefied. The breakdown voltages of $SF_6$ were more higher than l-Air except for 4[atm] at $-10{\sim}0[^{\circ}C]$.

  • PDF

Dry-Air의 습도에 따른 절연파괴 특성 (The Breakdown Characteristics for Dry-Air with Humidity Variations)

  • 박혜리;김영수;최은혁;박광서;김이국;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.238-240
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of Dry-Air and air based on their dew point and humidity variations in experimental GIS model by applying AC voltage. The breakdown voltage of Dry-Air was increased as gap length had been increased. The characteristics of Dry-air which had low dew point were higher. In the case of air, the breakdown voltage curves were like Dry-Air' s. But the curves were slightly folded up and down because of impurities.

  • PDF

대기압하에서 액체질소(LN2)방전특성에 관한 연구 (A study on the discharge characteristics of liquid nitrogen at atmospheric pressure)

  • 이영근;주재현;김상구;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.58-62
    • /
    • 1993
  • This paper shows the discharge characteristics of liquid nitrogen under plane to plane electrode, needle to plance electrode, inserting teflon insulator in plane to plane electrode at atmospheric pressure. The main experimental device of this paper is cryostat. The important results obtained from this study are sa follows. Breakdown voltage of LN2 under N-P electrode is higher than that of under P-P electrode at atmospheric pressure. Breakdown duration time is longer with increase of electode gap under the P-P, N-P electrodes. The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed. Breakdown voltage and breakdown duration time are in proportion to increase of diameter in case of inserting teflon insulator. Partial discharge characteristics of thickness 0.5[mm] is that 채굼 voltage of teflon insulator rose with increase of diameter in each [pps].

  • PDF

불평등 전계에서 SF6/N2 혼합가스의 AC 절연파괴전압 시뮬레이션 및 실험값와의 비교 (AC Breakdown Voltage Simulation of SF6/N2 Mixture in Non-Uniform Field and Its Comparison with Experimental Values)

  • 이병택;황청호;이태호;허창수;장용무
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1416-1422
    • /
    • 2010
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. At present study the breakdown characteristics of $SF_6/N_2$ mixtures in Non-uniform field was performed. In this paper, The simulation value are compared with experiment values. Streamer breakdown criterion was used for predicting breakdown voltage. For accurate simulation this simulation apply utilization factor using CST(computer simulation technology) EM $studio^{tm}$ program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. The pressure range of gas mixtures was 0.4 MPa to 0.7 MPa. The rod-plane was used and mixture ratio is $SF_6$ 20% : $N_2$ 80%. The gap lengths are 10mm to 70mm. As the pressure increase, this simulation value does not correspond to the experiment value. So this simulation need surface roughness factor. As a result of applying surface roughness factor this simulation decrease a relative error (|experiment value - simulation value| /simulation value).