• Title/Summary/Keyword: Electrical apparatus

Search Result 694, Processing Time 0.033 seconds

Investigation of the orientational changes of monolayer on the water surface by measuring the displacement current. (변위전류 측정에 의한 수면상 단분자막의 배향변화 관찰)

  • Park, Tae-Gone;Song, Kyung-Ho;Park, Keun-Ho;Kwon, Young-Soo;Kang, Dou-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1320-1322
    • /
    • 1994
  • Photoisomerization characteristics of 4-octyl-4'-(5-carboxy-pentamethyleneoxy) azobenzene molecules (8A5H) were attained by measurement of absorbtion spectra. 8A5H in chroloform($6.0{\times}10^{-5}[M/l]$) shows trans to cis and cis to trans isomerization by irradiation of lights of 360[nm] and 450[nm] wavelength. From LB monolayer films of 8A5H, also the cis/trans photoisomerization was obtained and it has reversibility and memory characteristics. We are now trying to detect these properties of 8A5H electrically. On this paper, we investigated the structural changes of monolayer on the water surface by measuring the displacement current as a preliminary experiment. The measuring system was constructed at home-made Kuhn type LB(Langmuir-Blodgett) deposition apparatus. 8A5H solution was spreaded at the air-water interface and the currents induced by the dynamic behavior of molecules were measured when the molecules were pressed by barrier. The reversibility of displacement currents by compression and expansion was obtained from 8A5H molecules, which shows the compressed molecules have a tendency to disperse after the compression. From this experiment, we conclude that the behavior of molecules on water surface can be monitored electrically by using this current measuring method, and this method can also be applied to detect the photoisomerization of monolayers on water surface.

  • PDF

Design of Stack Monitoring System with Improved Performance (성능이 향상된 Stack Monitoring System의 설계)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seong-Won;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.299-302
    • /
    • 2016
  • In this paper, we designed the stack monitoring system with improved performance. To block the incoming pulse noise to the amplifier, shield and the power supply impedance are reduced and the power circuit is isolated. The control unit is developed with variable high voltage, adaptive gain, offset and threshold in order to match the scintillation detector characteristic to the apparatus. 300-1500V variable high voltage power circuit is configured applicable to various scintillation detector. Stack monitoring system with improved performance guarantee the efficiency and the reliability by considering the characteristic of various scintillation detector. Developed stack monitoring system is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.

A Personal Reformer(PR) for your Fuel cell system (연료전지를 위한 개인용 개질기)

  • Kim Hyeon Yeong
    • 한국전기화학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.103-108
    • /
    • 2004
  • The present paper relates to an apparatus in which all carbonaceous material such as coal, oil, plastics and any substance having carbon atoms as part of its constituents are reformed(gasified) into syngas at temperature above $1,200^{\circ}C$(KR patent No.0391121, and PCT/KR2001/01717 and PCT/KR2004/001020). It comprises a single-stage reforming reactor without catalyst and a syngas burner as shown in Fig.2. syngas is combusted with $O_2$ gas in the syngas bunter to produce $M_2O$ and $CO_2$ gas with exothermic heat. Reaction products are introduced into the reforming reactor, reaction heat from syngas burner elevate the temperature of reactor above $1,200^{\circ}C$, and reaction products reduce carbonaceous material down to CO and $H_2$ gases. Reactants and heat necessary for the reaction are provided through the syngas burner only, Neither $O_2$ gas nor steam are injected into the reforming reactor. Reformer is made of ceramic inner lining and sst outer casing. Multiple syngas burners may be connected to the reforming reactor in order to increase the syngas output, and a portion of the product syngas is recycled into syngas burner. The present reformer as shown in Fig.2 is suitable to gasify carbonaceous wastes without secondary pollutants formed from oxidation. Further, it can be miniaturized to accompany a fuel cell system as shown in Fig.3 The output syngas may be used to drive a fuel cell and a portion of electrical power generated in a fuel cell is used to heat a compact reformer up to $1,200^{\circ}C$ so that gas/liquid fossil fuel can efficiently reformed into syngas. The fuel cell serves as syngas burner in Fig.2. The reformation reaction is sustained through recycling a portion of product syngas into a fuel cell and using a portion of electric power generated to heat the reformer for continuous operation. Such reforming reactor may be miniaturized into a size of PC, then you have a Personal Reformer(PR).

  • PDF

A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE (전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Carbonic anhydrase influences asymmetric sodium and acetate transport across omasum of sheep

  • Rabbani, Imtiaz;Rehman, Habib;Martens, Holger;Majeed, Khalid Abdul;Yousaf, Muhammad Shahbaz;Rehman, Zia Ur
    • Animal Bioscience
    • /
    • v.34 no.5
    • /
    • pp.880-885
    • /
    • 2021
  • Objective: Omasum is an important site for the absorption of short chain fatty acids. The major route for the transport of acetate is via sodium hydrogen exchanger (NHE). However, a discrepancy in the symmetry of sodium and acetate transport has been previously reported, the mechanism of which is unclear. In this study, we investigated the possible role of carbonic anhydrase (CA) for this asymmetry. Methods: Omasal tissues were isolated from healthy sheep (N = 3) and divided into four groups; pH 7.4 and 6.4 alone and in combination with Ethoxzolamide. Electrophysiological measurements were made using Ussing chamber and the electrical measurements were made using computer controlled voltage clamp apparatus. Effect(s) of CA inhibitor on acetate and sodium transport flux rate of Na22 and 14C-acetate was measured in three different flux time periods. Data were presented as mean±standard deviation and level of significance was ascertained at p≤0.05. Results: Mucosal to serosal flux of Na (JmsNa) was greater than mucosal to serosal flux of acetate (JmsAc) when the pH was decreased from 7.4 to 6.4. However, the addition of CA inhibitor almost completely abolished this discrepancy (JmsNa ≈ JmsAc). Conclusion: The results of the present study suggest that the additional protons required to drive the NHE were provided by the CA enzyme in the isolated omasal epithelium. The findings of this study also suggest that the functions of CA may be exploited for better absorption in omasum.

The Effect of the Purity of Raw Materials on the Purity of Silicon Extracted by Solvent Refining and Centrifugation (용매정제법과 원심분리법으로 추출한 Si의 순도에 미치는 장입 원재료 순도의 영향)

  • Cho, Ju-Young;Seo, Kum-Hee;Kang, Bok-Hyun;Kim, Ki-Young
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.12
    • /
    • pp.907-911
    • /
    • 2012
  • High purity silicon can be obtained from Al-Si alloys by a combination of solvent refining and centrifugation. Silicon purification by crystallization of silicon from an Al-Si alloy melt was carried out using 2N and 4N purity aluminum and 2N purity silicon as raw materials. The effect of the purity of raw materials on the final silicon ingot purity by centrifugation was investigated for an Al-50 wt% Si alloy. Alloys were melted using an electrical resistance furnace, and then poured into a centrifuging apparatus. A silicon lump like foam was obtained after centrifugation and was leached by an acid in order to get pure silicon flakes. Then silicon flakes were melted to make a silicon ingot using an induction furnace. The purities of the silicon flakes and silicon ingot were enhanced significantly compared to those of the raw materials of silicon and aluminum. The silicon ingot made of 4N aluminum and 2N silicon showed the lowest impurities.

Calibration of Borehole Roughness Measurement System for Large Diameter Drilled Shafts in Water (수중에서 적용가능한 대구경 현장타설말뚝의 굴착공 벽면거칠기 측정장치의 보정에 관한 연구)

  • Park, Bong-Geun;Nam, Moon-S.;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.5-21
    • /
    • 2009
  • Based on recent studies on rock socketed drilled shafts, it was found that the side resistance of rock socketed drilled shafts is affected by unconfined compressive strength of rock, socket roughness, rock types and joints, and initial normal stress. Especially, the socket roughness is affected by rock types and joints, drilling methods, and diameters. Since existing roughness measurement systems could be conducted only in the air, a new roughness measurement system, which can measure rock socket roughness in the air and also in the water, is needed. However, the development of new roughness measurement system fur civil engineers has been faced with difficulties of electrical applications. In this study, the laboratory verification system far BKS-LRPS (Backyoung-KyungSung Laser Roughness Profiling System) was developed, which can be applied both in the water and air. Based on the laboratory verification, it was found that the improved BKS-LRPS could define effective measurement distances for the conditions reflecting the apparatus and in-situ situations.

A Survey on the Utilization and Demand of Thermotherapy Devices in Korean Medical Institutions (한방의료기관의 온열 치료 기기 활용 현황 및 개발 수요에 대한 조사 연구)

  • So-Young In;Su-Ran Lim;Ji-Yeun Park;Jung-Hwan Park;Song-Yi Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.194-205
    • /
    • 2023
  • Objectives : This study investigated the current utilization status of thermotherapy devices in Korean medicine (KM) institutions and identified areas for improvement and further development, as perceived by KM doctors (KMDs). Methods : An online survey was conducted, targeting KMDs primarily engaged in clinical patient care. The questionnaire included items about respondents' clinical practices, the extent of thermotherapy device usage, their opinions on these devices, and perceived improvement needs. The collected data underwent quantitative analysis. Results : From the 1,025 respondents, data from 862 respondents who provided complete responses were analyzed. On average, respondents utilized thermotherapy treatments for 80% of their patients. Infrared (IR) phototherapy unit, electrical moxibustion apparatus, and heater-based thermotherapy devices were predominantly owned by respondents, with IR being the most frequently used. The average satisfaction score for current thermotherapy devices was 79. A significant concern raised was the necessity for improved health insurance coverage and efficacy evaluation. Conclusions : This research has confirmed that the extensive use of thermotherapy devices by KMDs in treating primarily musculoskeletal and gastrointestinal ailments - common conditions among patients in KM institutions. The main areas identified for improvement encompass safety, cost-effectiveness, and device efficacy. Future enhancements in thermotherapy devices should address these crucial aspects.

Study on the Environmental Factors and Symptoms of VDT Syndrome (VDT 증후군의 환경적 요인과 증상에 대한 연구)

  • Jeong, Seunghui;Lee, Seon Young;Eu, Sun Mi;Kim, Douk-Hoon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2009
  • Purpose: Recently incidence of VDT syndrome has gradually increased as extensive use of computers. VDT syndrome reported by VDT workers include musculoskeletal disorder, neuropsychiatric disoders and eye symptoms such as eye strain, tired eyes, irritation and blurred vision. The environmental factors of VDT syndrome include electromagnetic waves, size, brightness and lighting of computer screen, height of a monitor and a worktable, working hours, kind of task, distance between screen and workers, indoor humidity and temperature, indoor air contamination and ventilation. In this study, we investigated the environmental factors related to body symptoms and health effects included in VDT syndrome. Methods: Study subjects were total 120 persons (54 male, 66 female) with age from 19 to 28. We surveyed the body symptoms and physical discomfort when doing an activity in a short distance such as reading book or paper, computer work. The questionnaire included main body symptoms, self-consciousness symptoms of eye, satisfaction of working environment, pain of the wrist when using keyboard and mouse. Results: Most of people (70%) felt physical pain from long time work of computer, paper, electrical apparatus. They mainly complained pain of neck and low back (57.1%), eye (45.2%) and head (31%). With the environmental factors, 78.3% of the subjects complaint pain of eye from inappropriate illumination. Most of the symptoms included 'eye fatigue'(38.3%), 'dryness of eye'(31.9%) and 'blurred vision'(23.7%). Subjects in this study complained discomfort of their chairs and most of them experienced pain in the wrist when using keyboard or mouse. Conclusions: When people use electrical apparatus or work with paper, people would get their eye fatigue and feeling of physical fatigue because of not harmonizing various environmental factors such as light, space, posture, worktable with theirselves. Therefore, workers should develop preventive method such as self-control of adequate break time to avoid fatigue while VDT work. Work environment should be changed to ergonomic design for optimal visual environment to prevent musculoskeletal disorder through constant research.

  • PDF

Sensorless Speed Control of PMSM for Driving Air Compressor with Position Error Compensator (센서리스 위치오차보상기능을 가지고 있는 공기압축기 구동용 영구자석 동기모터의 센서리스 속도제어)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.104-111
    • /
    • 2018
  • The sensorless control of high efficiency air compressors using a permanent magnet type synchronous motor as an oil-free air compressor is quite common. However, due to the nature of the air compressor, it is difficult to install a position sensor. In order to control the permanent magnet type synchronous motor at variable speed, the inclusion of a position sensor to grasp the position of the rotor is essential. Therefore, in order to achieve sensorless control, it is essential to use a permanent magnet type synchronous motor in the compressor. The position estimation method based on the back electromotive force, which is widely used as the sensorless control method, has a limitation in that position errors occur due either to the phase delay caused by the use of a stationary coordinate system or to the estimated back electromotive force in the transient state caused by the use of a synchronous coordinate system. Therefore, in this paper, we propose a method of estimating the position and velocity using a rotation angle tracking observer and reducing the speed ripple through a disturbance observer. An experimental apparatus was constructed using Freescale's MPU and the feasibility of the proposed algorithm was examined. It was confirmed that even if a position error occurs at a certain point in time, the position correction value converges to the actual vector position when the position error value is found.