• 제목/요약/키워드: Electrical apparatus

검색결과 694건 처리시간 0.023초

대기전력 측정을 통한 절전 잠재량 예측 (Potential Electrical Energy Saving by Stand-by Power Measurement)

  • 최재원;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.253-255
    • /
    • 1999
  • We measured stand-by power of electrical machinery and appliance which are used at office and house. And we estimated potential electrical energy saving through stand-by power and the expecting number of supplied apparatus. As a result, We can reduce electrical energy by minimizing a stand-by power consumption up to three billion kWh which are equal to about 1/3 of an atomic power plant's generating power of 1 year.

  • PDF

초고압 가스차단기용 노즐의 재질에 따른 내아크 특성 (Arc-Withstanding Characteristics with respect to the nozzle material for EHV Class Gas Circuit Breakers)

  • 정진교;송기동;박경엽;송대진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.860-863
    • /
    • 2002
  • Recently, main nozzle and inner nozzle for EHV class gas circuit breakers were made by PTFE(Poly Tetra Fluoro Ethylen) for the basic material composite. But, nowadays strengthened PTFE was demanded because the supply of electric power increased. This paper shows the research results for nozzles according to the filler materials.

  • PDF

주상 변압기용 비정질 코어의 자장인가 코일 제작 (Magnetic Field annealing apparatus for Clamped Amorphous Transformer Core)

  • 송재성;정순종;김기욱;김병걸;황시돌;정영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 1996
  • In amorphous transformer core, magnetic field annealing is required for inducing uniaxial magnetic anisotropy to circular direction of the core. Generally annealing temperature is about foot, so insulator using in solenoid bed must have a high temperature stability, mechanical strength and good machinability. In this study, we made the magnetic field annealing apparatus using insulators, conductors, connectors and power supply. And then tested the apparatus in annealing process of 50 kVA amorphous transformers.

  • PDF

소비에너지 절약을 위한 공기압 실린더 구동장치의 파라미터 선정방법 (A Study on the Selection Method of Parameters for Energy Saving in Pneumatic Cylinder Driving Apparatus)

  • 장지성
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.60-65
    • /
    • 2012
  • Pneumatic actuators are clean, lightweight, and can be easily serviced, whereas low energy efficiency has been considered as a critical shortcoming compared with corresponding hydraulic and electrical actuators. This study describes a new design method of pneumatic cylinder driving apparatus by lowering a supply pressure. The simulation study demonstrates that the designed system with the proposed method can operate at the smaller energy consumption state compare to the designed system with the conventional method for the specified working conditions.

사다리꼴 형태 부상용 전자석의 유효길이 평가 방법 (EVALUATION METHOD FOR THE EFFECTIVE LENGTH OF TRAPEZOIDAL-TYPE ELECTROMAGNET)

  • 구대현;강도현;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.593-596
    • /
    • 1992
  • An evaluation method for the effective length of electromagnet - which bas U-shape in frontview and trapezoidal in side view - is presented. Using 2D FEM, 2 analysing models are introduced for calculating effective length of the magnet ; the front model is using the normalized equi-pole face area of the magnet and the side model using the normalized equi-magnetic circuit. The ratio of the effective length to the length of bottom plate (core) comes out 1.25 - 1.30. In addition, 3D FEM analysis has been done and a proto-type test model is manufactured to verify the analysing method. The ratio by the experiment appears 1.2, which is reasonably in good agreement with the suggested numerical results.

  • PDF

765KV 변전설비 운전중 상태감시 및 진단을 위한 전문가시스템 개발 (Development of Expert System to Diagnose and Monitor 765KV Power Apparatus in On-line Condition)

  • 최인혁;권동진;정길조;유연표;김광화;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.699-701
    • /
    • 2001
  • The expert system monitoring and diagnosing 765kV power apparatus was described in this paper. To develop this expert system, we studied the knowledge bases and data bases for 765kV transformer and GIS. In order to make the reliable inference of knowledge base and the good MMI(Man Machine Interface), the data bases were consisted of the tables of power apparatus information, limit level value, measured input data, inference result and diagnosis result. The knowledge base had various rules to infer the conditions of transformer and GIS. We applied both the forward chaining and backward chaining methods to these rules of system for good inferences. This paper describes the applied methods for expert system. Also, this developed system was tested with dissolved gas analyzing result and the result was shown.

  • PDF

구조개편에 따른 심야기기 보급정책과 심야요금의 변화 (A Study on Supply and Rate Policy of Midnight Power Apparatus in the Deregulation)

  • 김창수;이창호;이근대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.410-412
    • /
    • 2002
  • So far, electricity rate under the midnight hour incorporates policy consideration and maintains fixed irrespective of generation cost. Therefore, the promotion of midnight power apparatus has been rapidly increased due to increasing difference in substitute heating cost. This paper estimates the power supply cost during midnight times and analyzes the rate mechanism which can promote economic midnight power apparatus. In addition it provides the alternative on the direction of policy after the restructuring.

  • PDF

수력 발전기 고정자 권선의 절연수명 평가기준 설정에 관한 연구 (A Study on the Evaluation Criteria for the Remaining Life of Hydro-Generator Stator Insulation)

  • 황돈하;김용주;김진봉;박명수;김희곤;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1769-1773
    • /
    • 1996
  • The remaining life of generator stator winding has been the controversial issue amomg many experts in this area. The report from Japan claims that they can predict the remaining life of generator winding, while the North American has the negative opinion about it. This study aimed at verifying the validity of both Japanese criteria and North American argument on evaluation of generator winding insulation. Non destructive and destructive tests were performed on two hydro-generators. The test results showed that the trend analysis of stator winding insulation was the better option.

  • PDF

유전가열장치에 의한 곡물 바구미 구제의 실험적 고찰 (The Experimental Consideration for Extermination of a Rice Weevil in Grain by Dielectric Heating Apparatus)

  • 한경희;김태진;조기연;이현우;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.257-259
    • /
    • 2002
  • With development of Circuit technology, accuracy of dielectric or induction heating apparatus was developed. This study aims at realization of food insecticidal apparatus using dielectric heating. Equipment to measure grain's permittivity or vermin's permittivity and expectation for heating temperature by computer simulation is necessary for construction of the system. And the effect of extermination of vermin for food was confirmed by experiment using the system.

  • PDF

모터 부하시험을 위한 부하인가 장치 개발 (Development of Load apparatus for Motor)

  • 임병주;박창대
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.26-32
    • /
    • 2009
  • We have constructed loading apparatuses to electrical motor with a powder brake and a oil pump for load test of a several ten kilowatt-motor and performed load test with two motors. On operating the loading apparatus with a oil pump, temperature of the oil may excessively increase and fail to operate due to dynamic energy loss of equipment in oil loop. In order to control the oil temperature, factors of the energy loss were analyzed and the quantitative loss was calculated. Load tests of motors with two loading apparatuses constructed were successfully performed and strengths of each apparatus come out on operating.