• Title/Summary/Keyword: Electrical and electronic equipments

Search Result 192, Processing Time 0.021 seconds

Study On The Protective Effect of Lightning Surge for Electronic Equipments According to Installation Methods of Surge Protective Device (서지보호소자의 설치방식에 따른 기기의 뇌보호효과 검토)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.616-619
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

The Protection Effect of Lightning Surge for electronic Equipments According to Installation of Surge Protective Device and Earth Leakage Breaker (서지보호소자와 누전차단기 설치에 따른 기기의 뇌보호 효과)

  • Lee, Suck-Woo;Ko, Yeon-Sung;Yeo, Dong-Goo;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.90-92
    • /
    • 2005
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation of surge protective device and Earth Leakage Breaker.

  • PDF

Discussion On The Protective Effect of Lightning Surge based on The Surge Protective Devices for Low Voltage (저압 피뢰기 적용시 뇌서지 억제 효과 검토)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.40-42
    • /
    • 2004
  • Electronic equipments made from electrical circuits with small-sized semiconductor are very weak against lightning surge. So, electronic equipments is protected by SPD(surge protective devices) such as Zno varistor. The SPD protect electronic circuit in electronic equipments and AC power lines from the lightning surge. Therefore to achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect and installation method of surge protective device. Therefore this paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

A Study on the Motor Overload Interrupt system (전동기 과부하 차단 시스템에 대한 연구)

  • Choi Jang Gyun;Yoon Suk Am;Gang Byeong Bog;Lee Jeong Il;Cho Kyeng Jai;Cha In Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.73-76
    • /
    • 2002
  • In electrical machinery and apparatus, the most important problem is protect of machinery and apparatus in due to transient phenomena and overload on operation. Particularly by advanced technology of late, there Is demand for low cost of equipments and high percentage of use of equipments. Therefore, protection of machinery and apparatus In condition of overload is more valued considering that all efficiency increase is passed by operating all machinery and apparatus in condition of heavyload. In this paper, the suggested system is added overload interrupt system using CT in condition of overload.

  • PDF

A Study on the Standard Method to Calculate Recyclability Rate of Electrical and Electronic Equipments (전기전자제품의 재활용가능률 표준산정방법에 관한 연구)

  • Yi, Hwa-Cho;Kang, Hong-Yun;Shim, Kang-Sik;Kim, Jin-Han;Sim, Jae-Sul
    • Clean Technology
    • /
    • v.15 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • European directive DIRECTIVE 2002/96/EC requires the minimum recycling & recovery rate on the waste electrical and electronic equipments (WEEE). But, they do not have guidelines on the calculation methods for recycling and recovery rate. A standard method to calculate recyclability and recoverability rate of products in the designing stage is necessary for the manufacturers so that they can reflect the calculated result to the improvement of product design. In this work, we investigated the existing calculation methods for the recycling and recovery rates of WEEE and the recyclability and recoverability rates of electrical and electronic equipments (EEE). A method for the calculation of recyclability and recoverability rates for the EEE products in the development stage was developed. The newly-developed calculation method was applied to some EEE products and the calculated results were evaluated.

An Implementation for Effective Shielding System of Information Electronic Equipments (정보가전기기의 효과적인 차폐시스템 구현)

  • Kim, Jae-Yee;Jeong, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2031-2033
    • /
    • 2004
  • In this paper, electromagnetic wave environment generated from electronic equipments was investigated. Since the main source of electromagnetic waves are electronic equipments, the field intensity of a harmful electromagnetic wave was measured and its harmful level was analyzed. It was also found that the result was 23%${\sim}$38% in case of TV set and microwave oven. Based on this analysis, this study proposed efficient shielding method to suppress unwanted electromagnetic wave.

  • PDF

Outage Probability of the Device-to-Device Communication According to the Interference-to-Signal-Ratio Generated by Cellular Networks (셀룰러 시스템의 간섭에 의한 D2D 시스템의 Outage 확률 분석)

  • Min, Hyun-Kee;Seo, Woo-Hyun;Park, Sung-Soo;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • In this paper, the outage probability of device-to-device (D2D) uplink communication underlaying cellular networks is analyzed over Rayleigh fading. We assume that a D2D pair and M cellular user equipments share the same frequency resources. To prevent any harmful interference from a D2D transmitter to the BS, the maximum transmit power of the D2D transmitter is strictly limited. Under these assumptions, the outage probability is represented as a function of the interference-to-signal ratio from M cellular user equipments to a D2D receiver and the number of cellular user equipments, M. In addition, the interference-to-signal ratio is represented as a function of distances among D2D equipments, cellular user equipments and the BS. Simulation results validate these analytical results.

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard (전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kang, D.S.;Kim, J.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

카본파이버 매트 전극접지 기술

  • Choe, Un-Gu;Eom, Ju-Hong;Kim, Gwang-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.32-40
    • /
    • 2008
  • Recently, due to the onset of the information age, various high-priced, large-size machines have been invented such as intelligent building and high-tech computer operated facilities. Consequently, all kinds of electrical, electronic, and communication equipments and facilities have been found to be vulnerable even to small amounts of electrical shock. Interference between equipments and equipment malfunction occur because of various electromagnetic interferences. Galvanic action by direct current (D.C.) causes gas valve corrosion and other electrical problems such as static electricity and electromagnetic interference (EMI) occur as well. Most of the problems stated above occur because of problems in grounding.

  • PDF

Analysis of faust cause & insulation degradation on the electrical equipments for railway (철도용 전기기기의 고장요인 및 절연열화 분석)

  • 왕종배;전한준;박옥정;온정근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.