• Title/Summary/Keyword: Electrical Resistivity Method

Search Result 838, Processing Time 0.039 seconds

Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System (접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰)

  • Lee, Bok-Hee;Kim, Ki-Bok;Lee, Seung-Hoon;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.

Image Reconstruction of Subspace Object Using Electrical Resistance Tomography

  • Boo, Chang-Jin;Kim, Ho-Chan;Lee, Yoon-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2480-2484
    • /
    • 2005
  • Electrical resistance tomograpy (ERT) maps resistivity values of the soil subsurface and characterizes buried objects. The characterization includes location, size, and resistivity of buried objects. In this paper, truncated least squares (TLS) is presented for the solution of the ERT image reconstruction. Results of numerical experiments in ERT solved by the TLS approach is presented and compared to that obtained by the Gauss-Newton method.

  • PDF

Electrical and Optical Properties of ZnO Transparent Conducting Thin Films by Pyrosol Deposition Method (Pyrosol법에 의한 ZnO투명전도막의 전기적 광학적 특성)

  • 조우영;송진수;강기환;윤경훈;임경수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.965-970
    • /
    • 1994
  • ZnO transparent conducting oxide thin films have been prepared by Pyrosol deposition method and the effects of the different experimental variables on the electrical resistivity and optical transmittance of the prepared films have been investigated in details. The best film with a resistivity of about 8 X 10S0-2TΩcm and transmittance about 80% has been obtained at the substrate temperature of 4$25^{\circ}C$ by using HS12T+CHS13TOH(1:3) solvent and NS12T carrier gas after annealing at 20$0^{\circ}C$ for 40 minutes in vacuum. Furthermore, We have also found the effect of substrate temperature on crystallographic orientation and surface morphology. Annealing of the as-deposited film in vacuum leads to a substantial reduction in resistivity without affecting the optical transmittance and crystallographic orientation.

  • PDF

A Study on Electrical Resistivity Geophysical Surveys of the Noen Landfill Site (전기비저항 탐사를 이용한 노은매립장 침출수 분포에 관한 연구)

  • Kim, Jun-Kyoung;Hong, Sang-Pyo;Kim, Kwang-Yul;Cho, Yong-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.5
    • /
    • pp.223-230
    • /
    • 2004
  • The electrical resistivity prospecting method with dipole-dipole array were applied in order to survey 3-D structure characteristics of the Noen landfill site. For the electrical resistivity prospecting, 3 line of measurements were established parallel to the main boundary of the Noen landfill site and additional 2 lines were also established perpendicular to the existing 3 lines for the effective investigation of the landfill site. The results showed that the uppermost layer of the landfill site is believed to be stabilized generally based on the characteristics of electrical resistivity distribution. Lowest layer was partially polluted by the leachate.

Effects of Maximum Probe Spacing of Soil Resistivity Survery on Substation Grounding Analysis (변전소 접지설계를 위한 대지저항율 측정시 전극간 최대간격이 접지해석에 미치는 영향)

  • 정길조;곽희로;최종기
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.382-386
    • /
    • 2001
  • Presently, typical maximum probe spacing of soil resistivity survey(Wenners 4 pin method) is 20 m in case of 154 K substation grounding design of KEPCO. This paper examined the effects of maximum probe spacing of wenner method on the equivalent soil modeling and the accuracy of grounding resistance measurement by comparing the calculated FOP(Fall-of-Potential) curves of various soil models with the measured one at 154kV H substation. The comparison results showed that the inaccurate estimation of deep soil resistivity, which is caused from the short probe spacing of soil resistivity survey, can produce large errors on measurement of grounding resistance. In this paper a quantitative analysis of FOP at H substation has been presented.

  • PDF

Volume Resistivity Characteristies of Transformer Oils due to the Stirring Temperalure of BTA (BTA 교반온도에 따른 변압기유의 체적고유저항 특성)

  • 이용우;김석환;박문규;소병문;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.290-293
    • /
    • 1997
  • In this paper, volume resistivity is studied so that the electrical properties for transformer oil due to the stirring temperature of BTA is investigated. A measurement of volume resistivity using the VMG-1000 highmegohm meter is recorded after 10 minutes when the each voltage, and DC 100[V], 250[V], 500[V] and 1000[V] is applied, according to the step voltage appliaction method. A coaxial cylindrical liquid electrode to measure volume resistivity of specimen is used, and its geometric capacitance is 16[pF].

  • PDF

Electrical Resistivity Investigation at a Wastes Disposal Site (전기비저항 탐사를 이용한 매립지 안정화 조사)

  • Ha, Hee-Sang;Jung, Yun-Mun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.70-86
    • /
    • 2000
  • The primary objective of this study is to develope an investigating method to identify spatial variability of plumes and contaminants at contaminated sites. The electrical resistivity method was used to characterize contaminated sites. This technique is expected to use actively at contaminated sites in order to remedy the contaminated sites in the future. It was studied by appling electrical resistivity method into contaminated wastes disposal sites and verified that it was suitable method for the contaminated site characterization.

  • PDF

Dispersibility, Electrical Property of Nano-Composite by Solution Mixing Method (용액혼합법에 따른 나노복합재료 분산성 및 전기적 특성)

  • Yang, Hoon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.73-74
    • /
    • 2008
  • In this paper, we have investigated dispersibility, volume resistivity of nano-composite by solution mixing method. Dispersibility measured by FE-SEM(Field Emission Scanning Electron Microscope. And volume resistivity measured by ASTM D991. To expect interaction used dual filler system. But, dual filler system had influence on polymer complex. So, polymer chain mobility doesn't resist.

  • PDF

Electrical Structure Analysis of Ground using Various Methods for Resistivity Measurement (다양한 측정방법을 적용한 대지의 전기적 구조해석)

  • Jo, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1492-1493
    • /
    • 2006
  • Wenner 4-probe arrangement is used most widely by the method to measure soil resistivity and the measured data with the Wenner method are apparent resistivities of the soil. Therefore, the soil structure can be analyzed easily from the measured apparent resistivity, but the real soil resistivity is difficult to know correctly at a particular depth or at a specific location on earth surface. This paper introduces a method that can be used to decide the suitable burial depth and the electrode scale of a grounding rod effectively using soil structure analysis equipment based on the dipole-dipole method.

  • PDF