• Title/Summary/Keyword: Electrical Equipment

Search Result 2,800, Processing Time 0.031 seconds

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.

Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364 (IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구)

  • Kim, Soon-Sik;Han, Byeong-Gill;Lee, Hu-Dong;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.599-609
    • /
    • 2021
  • A novel grounding system, which is presented in IEC 60364, has been adopted since 2021. A safety evaluation for the human body on the grounding system is required due to the various characteristics of the touch voltage and current passing when the human body experiences an electric shock. The Korea Electrical Safety Corporation (KESCO) and Korea Electric Association (KEA) have been conducting a safety technical education on the grounding system. On the other hand, it is difficult to instruct the electrical safety manager because of a lack of safety evaluations for the test equipment on the grounding system. Therefore, this paper modeled and implemented a test device for a safety evaluation depending on the grounding system of IEC 60364. Namely, this paper presents the modeling of the test device for a safety evaluation using PSCAD/EMTDC S/W, which is composed of an AC grid section, s test device section on the grounding system, and a sub-device section. This paper implemented a test device for safety evaluation, which consisted of an AC grid section, TT grounding system section, TN-S grounding system section, and monitoring section. From the simulation and test results with the safety characteristics of the human body in the TT and TN-S grounding system, when the fault impedances are 0[Ω], 10[Ω], and 100[Ω], the currents passing through the human body in the TT grounding system are 104[mA], 87.4[mA], and 35.5[mA], respectively. The corresponding currents in the TN-S grounding system are 54.9[mA], 4.1[mA], and 0.4[mA], respectively. Based on the results, the protection performance for an electric shock to the human body in the TN-S system is better than the TT system. This can be improved when the existing grounding system is changed from the TT system to the TN-S system.

Analysis of the polychlorinated biphenyls in transformer oils using peak matching method (피크패턴법을 이용한 절연유 중 PCBs 분석)

  • Shin, Sun Kyoung;Kim, Hye-Jin;Chung, David;Jeon, Tae Wan;Kim, Jin Kyoung;Park, Seok Un;Chung, Young Hee;Chung, Il Rok
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.410-418
    • /
    • 2005
  • PCBs had numerous uses such as hydraulic fluid, heat exchange fluid, sealant, lubricant, and carbonless copy paper. They are most likely found in electric utilities, power stations, industrial facilities, electronic manufacturing plants, petrochemical plants, railroad systems, electric equipment repair facilities, mining sites (active or abandoned), and military camps. Due to its outstanding chemical and thermal stabilities and electrical insulation properties, the commercial and industrial products of PCBs, such as Aroclors, Kaneclors, Clophens, Phenaclors etc., had been widely used as thermal oil and transformer oil from 1930s until the 1970s. The transformer oils were analyzed as a main source of polychlorinated biphenyls (PCBs) emission into the environment. Qualitative estimation of oil extracts as carried out with Aroclor 1242, 1248, 1254, 1260. The transformer oils contained the pure and mixed of Aroclor 1242, Aroclor 1254, and Aroclor 1260. Also, commercial screening kit of 20 ppm and 50 ppm were applied to the transformer oil samples.

A Study on Methodology to Improve the Power Factor of the High Power LED Module (고출력 LED 모듈 역률 개선 방법 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.335-340
    • /
    • 2014
  • Recently, LED (Light Emitting Diode) becomes to be useful to apply for the lightening sources in electric systems and the lightening equipment since the power is less consumed with high efficiency, and the size and the weight of LED are small and light, respectively. The LED is controlled with constant current and SMPS (Switching Mode Power Supply). It is necessary for the LED manufacturer to secure the fundamental technology of designing LED chip, and to study the methodology to improve the power factor (PF) and to design the operational circuit for the development of LED to reduce the power loss in the application of LED lightening. The direct AC (Alternating Current) LED driving circuit, HV9910, is widely used in the industry field. In this paper, it is to evaluate the improved methodology for the power factor and efficiency through simulations when PFC (Power Factor Correction) and Noise Filter are added to HV9910.

Preparation of Sheet with CNT for EMI Shielding and Its EMI Shielding Property (CNT가 함유된 전자파 차폐흡수시트의 제조 및 전자파 차폐특성)

  • Chae, Seong-Jeong;Cho, Bum-Rae;Hong, Byung-Pyo;Lee, Byoung-Soo;Byun, Hong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.430-434
    • /
    • 2010
  • The sheet for electromagenetic interference (EMI) shielding was prepared with slurry made by the mixture of binder, methyl ethyl ketone, cyclohexanone and metal powder. We tried to enhance the shielding efficiency by adding carbon nanotube (CNT), which has known as highly conducting material. Surface and component analyses were carried out with SEM and EDS, respectively. The electric characteristics and EMI shielding efficiencies were measured with 4-point probe measurement and EMI efficiency measurement equipment. The sheet with 2% CNT addition showed the lowest electrical resistance, $13.13{\Omega}}{\cdot}cm$. It also showed the highest EMI shielding efficiency of 63 dB.

Development of Reuse Process Through Recovery and Refinement of Precursor for LED (LED용 precursor 재이용을 위한 회수 및 정제 공정 개발)

  • Yang, Jae Yeol;O, Byung Sung;Yoon, Jae Sik
    • Resources Recycling
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • The purpose of this research is to develop a process and a system to collect, purify and reuse the residual quantity of trimethylgallium, used as a raw material, upon GaN epitaxial growth for LED from a metal organic chemical vapor deposition(MOCVD) equipment. This research reviews whether TMGa collected from the process can be used through a chemical and structural characteristics evaluation. As a result of analyzing the purity using ICP-MS and ICP-AES, 7N high purity (99.99999%) of TMGa was obtained. According to checking the structural change of TMGa through NMR analysis, TMGa having pure $(CH_3)_3Ga$ structure was obtained without structural change. For reliability review of the collected TMGa, u-GaN was deposited using the MOCVD process and an structural, optical and electrical characteristics evaluation was conducted. As a result, it was found out that the reuse was possible.

A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.

Design and Development of Network for Housing Estate Security System

  • Nachin, Awacharin;Mitatha, Somsak;Dejhan, Kobchai;Kirdpipat, Patchanon;Miyanaga, Yoshikazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1480-1484
    • /
    • 2003
  • This paper presents the design and development of network for housing estate security system. The system can cover up to 961 houses which can be up to 1,200 meters long transfer rate of 9,600 bps. This system uses checking and warning the abnormal situation. More over this system has ability to control switch on/off the electrical equipment in the house via AC line control system. The system consists of 4 parts. The first part is a security system of each house using MCS-51 microcontroller as a central processing unit scan 32 sensors and control 8 appliances and send alarm. The MCS-51 microcontroller received control signal via telephone used DTMF circuit. The second part is distributed two levels master/slave network implementing after RS-485 serial communication standard. The protocol its base on the OSI (Open Systems Interconnection) 7 layers protocol model design focus on speed, reliability and security of data that is transferred. The network security using encrypt by DES algorithm, message sequence, time stamp checking and authentication system when user to access and when connect new device to this system. Flow control in system is Poll/Select and Stop-and-Wait method. The third part is central server that using microcomputer which its main function are storing event data into database and can check history event. The final part is internet system which users can access their own homes via the Internet. This web service is based on a combination of SOAP, HTTP and TCP/IP protocols. Messages are exchanged using XML format [6]. In order to save the number of IP address, the system uses 1 IP address for the whole village in which all homes and appliance in this village are addressed using internal identification numbers. This proposed system gives the data transfer accuracy over 99.8% and maximum polling time is 1,120 ms.

  • PDF

Analysis and Reduction of Crosstalk on Coupled Microstrip tines by Using FDTD Method

  • Pichaya Supanakoon;Monchai Chamchoy;Panarat Rawiwan;Prakit Tangtisanon;Sathaporn Promwong;Teerasilpa Dumwipata;Takada, Jun-ichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.523-526
    • /
    • 2002
  • The crosstalk among coupled microstrip lines is the major limiting factors of signal qualities in the high-speed digital and communication equipment. In this paper, a three-dimensional finite difference time domain (FDTD) method is applied to analyze the crosstalk between the coupled microstrip lines. The proposed structures of the coupled microstrip lines are investigated to reduce the coupling in a simple way by modifying their ground plane with an optimum gap. The examples of these structures with the different sizes of the gaps on their ground plane are studied. These structures are considered as the four-port network to evaluate transmission efficiency, near- and far-end crosstalk. Gaussian pulse is excited to evaluate the frequency characteristics from dc to 30 ㎓. The transmission efficiency, near- and far-end crosstalk of each structure of the coupled microstrip lines are demonstrated. The numerical results of this study show that the majority of crosstalk is the far-end crosstalk. The usage of the optimum gap on the ground plane can reduce the far-end crosstalk of the coupled microstrip lines while the transmission efficiency is nearly equal.

  • PDF

A Research on Personal Environment Services for a Smart Home Network (스마트 홈 네트워크를 위한 개인환경서비스 연구)

  • Ro, Kwang-Hyun;Kim, Seung-Cheon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.3
    • /
    • pp.46-55
    • /
    • 2012
  • Recently, the concept of PES(Personal Environment Service) is being widely discussed on various standardization organizations such as ITU-R, ETSI, 3GPP, TTA and etc. The purpose of PES is to introduce the services which can dynamically, automatically and intelligently reconfigures the electronic, electrical, and mechanical equipment surrounding the user according to the user preferences included in a user's profile by using a smartphone embedding WPAN radio technologies such as bluetooth and WiFi. This research introduces an Android Platform-based PES system which consists of a PES app, PES devices and a PES server. A smartphone platform is Android 2.2(Froyo) version and 4 simulated PES devices were implemented by using Galaxy Tab. It has shown that the PES would be a killer application of M2M(Machine-to-Machine) or D2D(Device-to-Device) in the future and it would need to study how to update a user's profile based on analyzing user's behaviour for enhancing the PES user's satisfaction.