• 제목/요약/키워드: Electrical Energy

검색결과 10,758건 처리시간 0.035초

Probabilistic Reliability Evaluation of Power Systems Including Wind Turbine Generators Considering Wind Speed Correlation

  • Wu, Liang;Park, Jeong-Je;Choi, Jae-Seok;Ei-Keib, A.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.485-491
    • /
    • 2009
  • The importance of renewable energy sources has been growing at a high rate as a result of being environment friendly. In particular, wind power is one of the most successfully utilized of such sources to produce electrical energy. Because of the randomness of wind speed, the reliability impact on this highly variable energy power is important aspect that needs to be assessed. In this paper, the impact on the reliability indices of wind speed correlation between two farms is considered.

철도역사 건물 전기용량 분석과 조명부하에 관한 연구 (Study on the Railway Station Building's Electrical Capacity Analysis and the Lighting Load)

  • 강옥구;장우진
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.102-106
    • /
    • 2014
  • Energy saving is as important as developments of green energy and alternative energy. The need for development of high-efficiency lighting apparatus further increased. This paper compared with the size of electrical equipment and analyzed the size of electrical capacity for the railway station building. Also discussed energy saving measures that can be achieved by using high-efficacy lighting fixtures, and the percentage of the lighting load capacity of the entire building.

수산화가스 발생기의 모델링 및 특성해석 (A Study on Analysis of the Hydrogen-Oxygen Gas Generator)

  • 강병회;이정민;목형수;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.198-201
    • /
    • 2001
  • The mixed gas of Hydrogen and Oxygen is gained from water electrolysis reaction. It has constant volume ratio 2 : 1 Hydrogen and Oxygen, and it is used as a source of thermal energy by combustion reaction. This gas has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG used for gas welding machine. So several studies of this gas are actively in progress nowadays. The object of this study is the optimization of power condition in the side of electrical for the high efficiency of water electrolysis equipment. First, chemical analysis of electrolysis is conducted, and the relation of electrical energy and chemical energy is quantitatively investigated. For basic experiment, unit electrode of singular electrolysis electrode is manufactured and experimented, results are compared and analyzed with simulation, and the electrolysis is electrically equivalent.

  • PDF

전력량 예측 및 부하 패턴을 근거로 한 부하 곡선 예측 (Electric Energy Forecasting and Development of Load Curve Based on the Load Pattern)

  • 지평식;조성현;이종필;남상천;임재윤;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.163-165
    • /
    • 1996
  • In this paper, we are proposed development of electric energy method and load curve. A daily electric energy is forecasted using artificial neural network. The load curve is obtained by combining forecasted electric energy and typical daily load patterns which are classified using KSOM and Fuzzy system. As a result, we know that we could get more accurate results and easier application than the results from based on the hourly historical data.

  • PDF

자가용전기설비의 전력원단위 향상을 위한 전력관리 방안 (Recommended Practice for the Improvement of the Unit Cost of Power Consumption in Non-utility Electrical Installation)

  • 김세동
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.235-240
    • /
    • 2000
  • This paper presents the reasonable method for electric power management through efficient use of electricity. With a rapid of national economics and living standard, electrical energy consumption markedly increased. Especially it is increased electrical energy consumption in commercial buildings and thus an energy conservation through efficient use of electricity became more important.

  • PDF

Evaluation Algorithms for Multiple Function of Dispersed Electrical Energy Storage Systems

  • Son, Joon-ho;Choi, Sung-Sik;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2245-2253
    • /
    • 2018
  • With the increase of electrical consumption and the unbalance of power demand and supply, power reserve rate is getting smaller and also the reliability of the power supply is getting deteriorated. Under this circumstance, the electrical energy storage (EES) System is considered as one of essential countermeasure for demand side management. This paper proposes efficient evaluation algorithms of multiple functions for EES systems, especially the secondary battery energy storage systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a quantitative manner, because they are very costly right now. In this paper, the multiple functions of EES systems such as load levelling, effective utilization of power distribution systems and uninterruptible power supply are classified, and then the quantitative evaluation methods for their functions are proposed. From the case studies, it is verified that EES systems installed at distribution systems in a dispersed manner have multiple functions involved with direct and indirect benefits and also they can be expected to introduce to distribution systems with respects to economical point of view.

Electric Field Energy Harvesting Powered Wireless Sensors for Smart Grid

  • Chang, Keun-Su;Kang, Sung-Muk;Park, Kyung-Jin;Shin, Seung-Hwan;Kim, Hyeong-Seok;Kim, Ho-Seong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, a new energy harvesting technology using stray electric field of an electric power line is presented. It is found that energy can be harvested and stored in the storage capacitor that is connected to a cylindrical aluminum foil wrapped around a commercial insulated 220 V power line. The average current flowing into 47 ${\mu}F$ storage capacitor is about 4.53 ${\mu}A$ with 60 cm long cylindrical aluminum foil, and it is possible to operate wireless sensor node to transmit RF data every 42 seconds. The harvested average power is about 47 ${\mu}W$ in this case. Since the energy can be harvested without removing insulating sheath, it is believed that the proposed harvesting technology can be applied to power the sensor nodes in wireless ubiquitous sensor network and smart grid system.

Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구 (A Study on Optimizing Energy Transfer of Capacitive Switching Antenna)

  • 김진만;방정주;허창수
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.