• 제목/요약/키워드: Electrical Accident

검색결과 518건 처리시간 0.034초

1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석 (Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault)

  • 최혜원;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

EMTP 시뮬레이션을 통한 배전선로의 1선 지락 사고시 화재 조사 기법에 관한 연구 (A Study on Fire Investigation Technique For Single Line to Ground Faults in Distribution Line Using EMTP Simulation)

  • 유정현;김희식;이훈기;조용선
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.21-26
    • /
    • 2018
  • Approximately 20% of the total fire is electrical fire, and electrical energy is a potential source of heat. Large-scale fault currents that occur during a line ground fault flow into electric utility poles, electric power equipment, or electric appliances of the customer, and cause simultaneous electrical fire. In this paper, we investigated the possibility of fire through the change of fault current flowing in faulty and sound feeder in case of 1 line ground fault in 22.9 kV distribution line. We propose a fire investigation analysis method for simultaneous multiple electrical fire such as evidence analysis method, and fault current occurrence confirmation method in case of fire accident by analyzing the fault current occurring in the ground fault in the distribution line using EMTP, electric power system analysis program.

Li-Polymer 배터리 사고원인 분석기법에 관한 연구 (Study on the Analysis Technique of Accident Cause for Li-Polymer Battery)

  • 이기연;방선배;김동욱;김재현;박진영;박광묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1541-1542
    • /
    • 2015
  • 본 논문에서는 휴대용 IT 기기 및 EV, ESS 등 사용이 급증하고 있는 리튬 폴리머 배터리의 화재사고 원인 분석기법에 대하여 나타내었다. 사고 원인 분석기법은 사례분석을 통하여 외형 및 탄화패턴 분석을 통한 발화 추정위치로 외력에 의한 사고 및 내부 절연 열화에 의한 사고 원인 분석 등을 나타내었다. 사고원인 분석은 배터리 안전성 확보와 사고 재발 방지를 위한 대책 마련에 필수적인 기술로 향후 증가하는 제품사고에 대한 분석기법 개발에 기초연구로 활용하고자 한다. 본 논문에서 제시한 분석기술과 향후 내부 절연 열화 원인 분석 기법을 개발하여 리튬 계열 배터리에서 발생하는 사고에 대하여 정확한 원인 분석에 활용할 것이다.

  • PDF

이동통신망의 SMS방식을 이용한 변전기기 무선진단 시스템 개발 (Development of Wireless Diagnostic System for Substation Equipments Using SMS Mode of Mobile Communication Network)

  • 김진철;김지호;윤만식;송호준;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2003
  • This paper suggests wireless diagnosis and monitoring system using SMS mode of mobile communication network for distribution transformer which could prevent electrical accident in the near future. Data are acquired by measuring the temperature of insulator oil in the distribution transformer and load current. Data acquisition of sensor using mobile communication network carried out filtering of sensor's output to optimize the size of send data Merit of this inspection method is that management, control and monitoring some transformers can be carried out using only one server. This inspection method will be the way of inspection to be worth spotlight in the near future because it is able to solve easily with the minimum facility inspection about state of transformer which is operating, to wide coverage about machine's wrong operation in other field.

  • PDF

IoT 활용 이동착탈식 열화 진단 장치 개발 (Development of Moving and Attaching Diagnosis Device Using IoT)

  • 가출현;이동규;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

열화상 영상을 이용한 래들의 내화물 열화도 분석 (Analyzing Refractory Bricks of Ladles using Infrared Images)

  • 이상준;전용주;김상우
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.291-300
    • /
    • 2015
  • In the steel manufacturing process heat-endurance deterioration of a ladle used to cause a big accident. In this paper, an infrared imaging system and image analyzing procedure are proposed for inspecting refractory bricks of a ladle. The proposed algorithm contains following three parts: two-stage image selection procedure, reference point detection, and analysis of heat-endurance deterioration. Experiments were conducted with real data from a steel plant and detailed configuration of infrared imaging system was presented.

GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용 (A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application)

  • 김종서;김진태;신흥식;이홍재
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구 (Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion)

  • 최충석;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

전기추진시스템의 부하저감 설계 및 해석 (Design and Analysis of Load Shedding for the Electric Propulsion System)

  • 김경화;김대헌;이석현
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.971-977
    • /
    • 2015
  • The electric propulsion system requires more reliability and safety than the conventional propulsion system because any sudden changes of electric system would bring tremendous effects on the ship's safety and propulsion. So it is very important to consider the potential transient effects. This paper discusses one of the worst electric accident. That is, one or two of generators are out of service in normal seagoing condition. And the appropriate measures are simulated in order to prevent the frequency decline that can bring the other generator's tripping. In addition, the relation between the transient effects and the major factors(inertia of generator/motors, governor's drooping characteristic and response speed) are also identified using the ETAP software.

화염에 의한 전기적 섬락특성 실험(I) (Electrical Flashover Characteristic Test by Gas Flames(I))

  • 손홍관;이형권;한형주;박인표;한세원;김병걸;오한호;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.450-451
    • /
    • 2008
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. Therefore, by studying flame's electrical conductivity, the paper recommended measures that can minimize transmission line's flashover accidents in the future, which can be caused by forest fire in a region where transmission lines pass through.

  • PDF