• Title/Summary/Keyword: Electric toothbrush

Search Result 22, Processing Time 0.027 seconds

Comparison of electric and manual toothbrushes on periodontal health in fixed orthodontic patients (고정식 교정환자에서 치주건강 유지에 대한 전동치솔의 효과)

  • Park, Seong-Joon;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.286-294
    • /
    • 2005
  • The purpose of this study was to evaluate the efficacy of an electric toothbrush, with a specially designed orthodontic brush head, compared to a manual toothbrush on the periodontal health of patients with fixed orthodontic appliances Forty patients were randomly divided into two groups. the electric and the manual toothbrush groups, 1 month after attachment of fixed orthodontic appliances. Periodontal status was measured using a plaque index, a gingival index. a bleeding index, a pocket depth and a relative attachment loss, at baseline and after 3 months. 6 months, 9 mouths. and 12 mouths. The Braun Oral-B Plak Control with Ortho OD 15-1 brush head was used as the electric toothbrush while the Butler G.U.M 124 was given as the manual toothbrush. In the manual toothbrush group, the giugival and bleeding indices showed no statistically significant differences, but the plaque index was significantly decreased (P<0.001) and pocket depth as well as relative attachment loss were significantly increased (p<0.01). In the electric toothbrush group. the bleeding index, pocket depth and relative attachment loss showed no statistically significant differences. but the plaque and gingival indices were significantly decreased (p<0.001). In the case of the plaque. giugival and bleeding indices, there were no statistically significant differences between the electric and the manual toothbrush groups. On the contrary, in the case of pocket depth and relative attachment loss, there were statistically significant differences between the electric and the manual toothbrush groups: an increase in the manual toothbrush groups unlike the electric toothbrush group which kept the same state (P<0.05) These findings suggest that an electric toothbrush is useful for orthodontic patients with fixed appliances.

A comparative study of electric and manual toothbrushes on oral hygiene status in fixed orthodontic patients (고정식 교정 환자에서 전동치솔 효과에 관한 연구)

  • Park, Chang-Hun;Hwang, Hyeon-Shik;Lee, Ki-Heon;Hong, Suk_jin
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.363-370
    • /
    • 2004
  • Patients with fixed orthodontic appliances frequently have increased levels of plaque accumulation leading to the possibility of gingivitis or enamel decalcification. Although many methods may be helpful in reducing dental plaque formation, the optimal mechanical removal of plaque is the most important factor during orthodontic treatment. The purpose of this study was to evaluate the efficacy of an electric toothbrush (with a specially designed orthodontic brush head) compared to a manual toothbrush in controlling plaque and gingivitis for patients with fixed orthodontic appliances. Oral hygiene status was measured in thirty-four patients using a plaque index, a gingival index and a bleeding index, before and four weeks after the attachment of fixed orthodontic appliances. Patients were randomly divided into two groups: electric and manual toothbrush groups. Oral hygiene instruction was given according to the type of toothbrush used. The Braun Oral-B D9511 with Braun Oral-B Ortho OD 15-1 brush head was used as the electric toothbrush while the Butler G.U.M. 124 was given as the manual toothbrush. After four md eight weeks, oral hygiene status was measured again. Through a comparison between the electric and the manual toothbrush groups, the following results were obtained. 1. All oral hygiene indices showed an increasing tendency after four weeks of fixed orthodontic appliance. 2. All indices presented a decreasing tendency four and eight weeks after oral hygiene instruction. 3. In case of the gingival index and bleeding index, the decreasing tendency did not show a statistically significant difference between the electric and the manual toothbrush groups. 4. The decreasing tendency of plaque index presented a statistically significant difference between the two groups, showing that the electric toothbrush was more effective in terms of oral hygiene. These findings suggest that an electric toothbrush is useful to orthodontic patients with fixed appliances.

Effects of an electric toothbrush combined with 3-color light-emitting diodes on antiplaque and bleeding control: a randomized controlled study

  • Kwon, Chakyoung;Lee, Jae-Mok;Suh, Jo-Young;Seo, Seung-Jun;Lee, Youngkyun;Kim, Yong-Gun
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.251-259
    • /
    • 2020
  • Purpose: This randomized controlled study aimed to evaluate the effects of an electric toothbrush with 3 colors of light-emitting diodes (LEDs) on antiplaque and bleeding control. Methods: This randomized, placebo-controlled, double-blinded, parallel-group clinical trial included 50 healthy adults with gingivitis, who were randomly assigned to 2 groups. The experimental group used electric toothbrushes with 3 colors of LEDs and the control group used the same electric toothbrush as the experimental group, but with LED sources with one-hundredth of the strength. The subjects used the electric toothbrush 3 times a day for 4 minutes each time. As clinical indices, bleeding on marginal probing (BOMP), the Löe-Silness gingival index (GI), and the Turesky-Quigley-Hein plaque index (QHI) were assessed at baseline, at 3 weeks, and at 6 weeks. Results: There were significant decreases in all clinical indices (BOMP, GI, QHI) in both the experimental and control groups compared to baseline at 3 weeks and at 6 weeks. In a comparison between the experimental and control groups, no statistically significant differences were observed for any clinical indices at 3 weeks (P>0.05). However, at 6 weeks, statistically significant differences were observed between the experimental and control groups in BOMP and GI, which are indicators of gingival inflammation (P<0.05). Conclusions: This study demonstrated that an electric toothbrush combined with 3-color LEDs reduced gingival bleeding and inflammation after 6 weeks.

An experimental study on plaque removal effect through the acting types of the electric toothbrushes (전동칫솔모의 작동형태에 따른 치면세균막 제거율에 관한 실험연구)

  • Lee, Cheon-Hee;Ahn, Sun-Ha;Jang, Young-Ho
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.4
    • /
    • pp.465-474
    • /
    • 2011
  • Objectives : The removal of most reliable mechanical dental plaque that is to say tooth brushing was generalized to control of dental plaque, many oral health goods have also developed due to the effect differences followed by individual habit. The electric toothbrush have studied and developed widely as major field of study that electric toothbrush having various moving phase was sold and developed at the market. Methods : Accordingly author studied about selling electric toothbrushes shape (vibration type, ultra-sonic minuteness vibration type, semi rotation type) to raise the efficiency after comparing to the moving them that total 8 groups classified by poor tooth models for example normal set of tooth, crowding tooth, bracket attached tooth, prosthetic status etc. and executed plaque removal effect on the tooth through comparing experiment. Results : The removal rate of artificial plaque on the tooth was improved in proportion to the increase of tooth brushing time(p<0.05). The ultra-sonic minuteness vibration and semi rotation type was superior to toothbrush of vibration type comparing to the removal rate of plaque on the tooth(p<0.05). Conclusions : The electric toothbrush of supersonic minuteness vibration and semi rotation type can be recommended most of tooth types regardless of oral tooth setting status for example, normal set of tooth, crowding tooth, bracket attached tooth, porcelain tooth.

Effect of 125 Hz and 150 Hz vibrational frequency electric toothbrushes on the rate of orthodontic tooth movement and prostaglandin E2 levels

  • Anadha N. Gujar;Prashantha Govinakovi Shivamurthy
    • The korean journal of orthodontics
    • /
    • v.53 no.5
    • /
    • pp.307-316
    • /
    • 2023
  • Objective: To evaluate the effects of an electric toothbrush with vibrational frequencies of 125 Hz and 150 Hz on the orthodontic tooth movement (OTM) rate and the production of prostaglandin E2 (PGE2). Methods: Out of thirty patients (aged 18-25 years; 16 females and 14 males), ten patients each formed Group A and B, who used electric toothbrushes with 125 Hz and 150 Hz vibrations, respectively. The remaining ten patients (Group C) served as the control group and did not use electric toothbrushes. The rate of OTM and levels of PGE2 using microcapillary pipettes were calculated before the start of retraction (T0), on the 30th day (T1), on the 60th day (T2), and on the 90th day (T3) from the start of retraction in all the groups. Results: There was a statistically significant difference in the mean OTM values and PGE2 levels in all three groups at different time intervals, with the maximum difference seen in Group B compared to Group A and least in Group C at T1, T2 and T3. Conclusions: The rate of OTM and levels of PGE2 were highest in patients who used an electric toothbrush with 150 Hz mechanical vibration compared to those who used an electric toothbrush with 125 Hz mechanical vibration and least in patients who did not use an electric toothbrush. Mechanical vibration led to an increase in the PGE2 levels and accelerated the OTM.

Research on the usage of oral hygiene devices and the general knowledge, attitude on oral health care in the orthodontic patients (교정환자의 구강건강관리에 관한 지식도와 태도 및 구강위생용품 사용실태)

  • Min, Hee-Hong;Na, Eun-Joo;Jun, Ji-Hean;Park, Young-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.399-407
    • /
    • 2012
  • Objectives : Purpose of this research is to determined the general knowledge on oral health and the usage of oral hygiene products in the orthodontic patients and try to provide an appropriate oral hygiene products for the patients. Methods : Orthodontic patients who visited a dental clinic in Daejeon were selected and data from 352 patients were collected. Questionnaire based on survey was conducted from 1st of March to 30th in 2011 and all the data was analysed by using SPSS statistical program (VER 15.0). Frequency analysis, $x^2$ test, T-test and the amount of diurnal variance analysis (one-way ANOVA) were also used. After that, scheffe's post-test method was conducted. Results : According to the general characteristics of oral health care knowledge score was $2.87{\pm}0.60$, the attitude score was $2.96{\pm}0.57$. toothbrush replacement cycle were less than 3 months (p=0.007, p=0.000) and frequency of brushing one day more than three times higher in patients with knowledge to help attitude. according to the sex, age, and duration of orthodontic treatment with oral hygiene devices of usage was higher in the calibration toothbrush usage, awareness was higher in the interdental toothbrushes. according to the type of orthodontic devices from the oral hygiene devices usage, removable group was the orthodontic toothbrush and electric toothbrush group were highest in the 'unknown', the fixed group was orthodontic toothbrush(67.3%) and electric toothbrushes(40.8%) was higher in the usage. Patients who used oral hygiene devices such as orthodontic tooth brush, interdental brush, electric toothbrush, water pik and fern solution showed wider knowledge on oral health care and oral hygiene devices compared to patients who answered as does not aware of oral hygiene devices and never used these products before. Conclusions : Orthodontic patient's oral health attitudes, knowledge, and oral hygiene devices usage are the general characteristics of the highest in the orthodontic toothbrush usage, awareness was higher in the interdental brush. Water pik and fern solution, rubber and gingival interdental stimulator turned massage does not use or low. Based on results from research, overall orthodontic patients who visited a dental clinic had low awareness and usage of oral hygiene devices. Therefore, it is required to educate general publics and the orthodontic patients and also promote the importance of usage of oral hygiene devices.

An convergence study on the effect of plaque removal through the number of operations of the electric toothbrushes (전동칫솔의 작동횟수에 따른 치면세균막 제거율에 관한 융합연구)

  • Moon, Kyung-Hui;Lee, Ji-Young;Kim, Jang-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2019
  • The study was to expand the choice of electric toothbrush by number of operations of the plaque removal effect on the tooth surface. Three different toothbrushes were selected for oscillations and pulsations type of electric toothbrush. A is Oral-B D12 (7,600 pulsations), B is Oral-B D16 (20,000 oscillations and a 7,600 pulsations), C is Oral-B D20 (40,000 oscillations and an 8,800 pulsations). In each trial, each tooth was brushed for 2 seconds. For the 10 trials. And each tooth was coated with 1layer, 2layers and 3layers. After the experiment, the plaque removal effect was calculated and analzed using the Image J program(p<0.05). According to the study, C toothbrush had the highest rate of plaque removal effect. Based on this results of the study, dental worker will need to evaluate oral hygiene and recommend appropriate toothbrushes according to oral conditions.

Efficacy of the Sonicare $Elite^{\Box}$ in plaque removal and reduction of gingival inflammation from hard-to-reach sites of the moderate periodontitis (증등도 치주염에서 칫솔모 도달이 힘든 부위의 치태 및 치은염 감소에 대한 Sonicare $Elite^{\Box}$ 의 효과)

  • Hong, Ji-Youn;Jung, Sung-Won;Urn, Yoo-Jung;Chae, Gyung-Jun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.693-703
    • /
    • 2006
  • The purpose of this study was to evaluate the efficacy of the Sonicare $Elite^{(R)}$ power toothbrush in plaque removal and reduction of gingivitis from hard-to-reach sites of the moderate periodontitis compared to regular manual toothbrush in 12 week follow-up. 82 subjects with incipient to moderate periodontitis were randomly assigned to use either the manual or sonic brush, instructed in its use, and asked to brush 2 times a day for 2 minutes. Plaque scores were taken at baseline, 1, 4, 12 weeks using Silness & $L\ddot{o}e$ plaque index and gingival inflammation was assessed by the $L\ddot{o}e$ & Silness gingival index. The results were as follows. 1. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant reduction(p<0.0001) of the plaque(Silness & $L\ddot{o}e$) and gingival inflammation(Loe & Silness). 2. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant better reduction of plaque and gingivitis(p<0.05) than the manual toothbrush after 1, 4, and 12 weeks. 3. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the plaque in interproximal sites(p<0.0001), buccal sites(p<0.0001) and the lingual sites(p=0.00l8) of the teeth. 4. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the gingival inflammation in the interproximal sites(p<0.0001), the buccal sites(p<0.0001) and the lingual sites(p<0.0001) of the teeth. The results of this study support the findings that Sonicare $Elite^{(R)}$ power toothbrush has a great potential to remove the plaque and resolve the gingival inflammation during the period of 12 week.