• Title/Summary/Keyword: Electric stations

Search Result 191, Processing Time 0.031 seconds

Forecasting of Inspection Demand for Pressure Vessels in Hydrogen Fuel Cell Electric Vehicle using Bass Diffusion Model (Bass 확산모델을 이용한 수소전기차 내압용기 검사수요 예측)

  • Kim, Ji-Yu;Kim, Eui-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.16-26
    • /
    • 2021
  • The global warming problem has arose, the supply eco-friendly vehicles such as HFCEVs is increasing around world and Korea is fully supporting subsidies, tax cut to form an initial market for HFCEVs. The key to the safety of HFCEVs is pressure vessels stored hydrogen, and although these pressure vessels must be inspection regularly, the existing inspection stations are insufficient to meet the demand for inspection. Therefore, it is important to establishment of pressure vessels inspection station for safety management of HFCEVs. In this study, it estimates innovation coefficient, imitation coefficient in Bass model by using electric vehicle sales data, and foretasted the supply of HFCEVs by region & the demand for inspection by region using the Bass diffusion model. As a result, the inspection demand for pressure vessels in HFCEVs in 2040 was 690,759 units, and it was confirmed 191 new inspection stations and 1,124 inspectors were needed to prepare for this.

Environmental Assessment of Smart Grid Station Project Centered on Pilot Project of Korea Electric Power Corporation Building

  • Park, Sun-Kyoung;Son, Sung-Yong;Kim, Dongwook;Kim, Buhm-Kyu
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.217-229
    • /
    • 2016
  • Increased evidences reveal that the global climate change adversely affect on the environment. Smart grid system is one of the ways to reduce greenhouse gas emissions in the electricity generation sector. Since 2013, Korea Electric Power Corporation (KEPCO) has installed smart grid station in KEPCO office buildings. The goal of this paper is two folds. One is to quantify the reduction in greenhouse gas emissions through smart grid stations installed in KEPCO office buildings as a part of pilot project. Among components of smart grid stations, this research focused on the photovoltaic power system (PV) and energy storage system (ESS). The other is to estimate the reduction in greenhouse gas emissions when PV is applied on individual houses. Results show that greenhouse gas emissions reduce 5.8~11.3% of the emissions generated through the electricity usage after PV is applied in KEPCO office buildings. The greenhouse gas emissions reduction from ESS is not apparent. When PV of 200~500 W is installed in individual houses, annual greenhouse gas emission reduction in 2016 is expected to be approximately $2.2{\sim}5.4million\;tCO_2-eq$, equivalent to 6~15% of greenhouse gas emissions through the electricity usage in the house hold sector. The saving of annual electricity cost in the individual house through PV of 200 W and 500 W is expected to be 47~179 thous and KRW and 123~451 thousand KRW, respectively. Results analyzed in this study show the environmental effect of the smart grid station. In addition, the results can be further used as guidance in implementing similar projects.

Brackish Lakes in Shinpo District North Korea. III. Fish

  • Gil, Joon-Woo;Hong, Young-Pyo;Park, Joon-Ho;Kim, Saywa
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2004.05a
    • /
    • pp.23-23
    • /
    • 2004
  • Four times of field survey were carried out to collect fish samples at six stations in Shinpo district, North Korea in October 1997, July 1998, May and October 2002. Sampling stations were located in upstream, middle and down of the southern river of Bukchong and three brackish lakes of lake Hommanpo, Daein and Hyunkum, respectively. A total of 29 species belonging to 11 families occurred. Family Cyprinidae showed the prosperity in species number of 28% among total species occurred. No natural monument fishes or rare species were captured. Ten commercial fishes, five anadromous ones and five brackish ones were identified. Feeding habits divided fish fauna with 11 carnivores, two herbivores and seven omnivorous ones. In the river, 20 species belonging to seven families inhabited, 18 species of 6 families in lake Homanpo, 21 of seven III Hyunkum and 23 of eight in Daein, respectively. Ecological indices of richness, diversity and evenness were highest in lake Daein and dominance index was highest in lake Hyunkum.

  • PDF

Forecasting Market Shares of Environment-Friendly Vehicles under Different Market Scenarios

  • Bae, Jeong Hwan;Jung, Heayoung
    • Environmental and Resource Economics Review
    • /
    • v.22 no.1
    • /
    • pp.3-29
    • /
    • 2013
  • The purpose of this study is to estimate consumer preferences on hybrid cars and electric cars by employing a choice experiment reflecting the various market conditions, such as different projected market shares of green vehicles and $CO_2$ emission regulations. Depending on different market scenarios, we examine as to which attribute and individual characteristic affect the preferences of potential consumers on green vehicles and further, forecast the potential market shares of green cars. The primary results, estimated by a conditional logit and panel probit models, indicate that sales price, fuel cost, maximum speed, emission of air pollutants, fuel economy, and distance between fuel stations can significantly affect consumer's choice of environment-friendly cars. The second finding is that the unique features of electric cars might better appeal to consumers as the market conditions for electric cars are improved. Third, education, age, and gender can significantly affect individual preferences. Finally, as the market conditions become more favorable toward green cars, the forecasted market shares of hybrid and electric vehicles will increase up to 67% and 14%.

Analysis on Effect Area of Subway Station Using GIS & Multi-temporal Satellite Images (GIS와 다시기 위성영상을 이용한 전철역세권의 분석)

  • Park, Jae-Kook;Kim, Dong-Moon;Yang, In-Tae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.2
    • /
    • pp.107-115
    • /
    • 2007
  • Among public transportation facilities within urban area, electric railway (subway) has been a regionally based facility that has played an important role in improving the foundation of territory development and arrangement of living foundation and living environment while supplementing the regional road network. In this regard, the subway stations should be allocated in the right place to ensure mobility, convenience and economic feasibility, some of transportation characteristics of road network combined with the subway. However, it would be very hard to evaluate quantitatively the effects of public transportation facilities such as subway in metropolitan cities on regional development and change in land use and to suggest the data that would be utilized in future city planning corresponding to their results. Therefore, this study evaluated the change in land use by the conditions of location of subway stations quantitatively; then, it evaluated and analyzed the change in land use for the internal and external parts of the surrounding areas of subway stations through the GIS spatial analysis and classification of landsat TM satellite image for utilizing it as reference material for the new establishment of subway stations in the future.

Feasibility Study of Pressure Letdown Energy Recovery from the Natural Gas Pressure Reduction Stations in South Korea (한국의 천연가스 도시정압기지에서 감압에너지 회수에 대한 타당성 연구)

  • Yoo, Han Bit;Hong, Seongho;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.9-17
    • /
    • 2015
  • Almost all of the natural gas consumed in South Korea is compressed into very high pressure for the transportation through the underground pipelines, then reduced in pressure regulation stations before delivery to the consumer. For pressure reduction, expansion valves have been used due to the simple and effective installation, but recover none of the energy in the gas during compression. Hence, turbo-expanders are proposed instead of the valves to accomplish the same pressure letdown function and recover some of the compression energy in the form of shaft work converting into electric powers. Here we have theoretically calculated the electric powers at the pressure reduction from 68.7 bar to 23 bar (which are the average values taken at the inlet and outlet points of the expansion valve in medium-pressure regulation stations) according to the inlet conditions of temperature and flow rate. The natural gas is considered as two cases of a pure methane and the mixture of hydrocarbons with a very small amount of nitrogen, and the Peng-Robinson equation of state is employed for the calculation of required thermodynamic properties. The electric energy is recovered as much as 1596 MW(methane) and 1567 MW(mixture) based on the total supply of natural gas in 2013.

Multi-Objective Optimal Predictive Energy Management Control of Grid-Connected Residential Wind-PV-FC-Battery Powered Charging Station for Plug-in Electric Vehicle

  • El-naggar, Mohammed Fathy;Elgammal, Adel Abdelaziz Abdelghany
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.742-751
    • /
    • 2018
  • Electric vehicles (EV) are emerging as the future transportation vehicle reflecting their potential safe environmental advantages. Vehicle to Grid (V2G) system describes the hybrid system in which the EV can communicate with the utility grid and the energy flows with insignificant effect between the utility grid and the EV. The paper presents an optimal power control and energy management strategy for Plug-In Electric Vehicle (PEV) charging stations using Wind-PV-FC-Battery renewable energy sources. The energy management optimization is structured and solved using Multi-Objective Particle Swarm Optimization (MOPSO) to determine and distribute at each time step the charging power among all accessible vehicles. The Model-Based Predictive (MPC) control strategy is used to plan PEV charging energy to increase the utilization of the wind, the FC and solar energy, decrease power taken from the power grid, and fulfil the charging power requirement of all vehicles. Desired features for EV battery chargers such as the near unity power factor with negligible harmonics for the ac source, well-regulated charging current for the battery, maximum output power, high efficiency, and high reliability are fully confirmed by the proposed solution.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

A Location Guide App Service for Electric Vehicle Charging Station using Public Data (공공데이터를 활용한 전기차 충전소 위치 안내 앱 서비스)

  • Kim, Jong-Woo;Oh, Sang-Hun;Min, Kyung-Hwi;Kim, Ki-Hyuk;Jung, Deok-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.370-372
    • /
    • 2017
  • Recently, at home and abroad, as the demand and supply of electric vehicles have increased, the spread of charging stations for electric vehicles is accordingly spreading out. In this paper, we provide the location, price, and service information of the electric car charging station through the big data analysis by using Open API of the public data and evaluation service provided by KEPCO, thereby inducing communication among users.

  • PDF

A Study on the Temperature Variation Characteristics of Electric Car Depending on Passenger Number (승객 수에 따른 전동차 객실공간의 온도변화 특성 연구)

  • Hahm, Dae-Ju;Park, Duck-Shin;Nam, Seong-Won;Maeng, Hee-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.393-399
    • /
    • 2008
  • A Study has been conducted on the characteristics of temperature variation depending on passenger number that is measured in Bundang Line(From Sunleng To Bojong). As a basic study, the air quality of passenger room for the electric rail car is evaluated. Although ISO7730 recommends that the height of measuring points for the heat environment is to set at 0.1m, 0.6m, 1.1m and 1.7m respectively, temperature are measured at two points at 1.1m and 1.7m because of the difficulty to measure temperature of 0.1m height in rush hour. We compared the results of temperature variations between two stations in rush hour(07:56-08:41). In general, the capacity of a passenger car is designed for 160 persons, but over 280 persons often board on electric rail in rush hour. The temperature of room is adjusted from $22^{\circ}C$ to $24^{\circ}C$, but it is measured from $26^{\circ}C$ to $28^{\circ}C$ on average. Therefore, it shows that there are difference between the set temperature and measured one. This article suggests the ways of the time adjusting and air-conditioning to satisfy customer's demand and the guide line to design the optimum capacity of air-conditioner of the new electric rail car which will be introduced in the near future.

  • PDF