• Title/Summary/Keyword: Electric safety

Search Result 1,827, Processing Time 0.03 seconds

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A research on the actual condition fire dangerousness for electric installation of stables (축사 전기설비 화재위험성 실태조사)

  • Lee, Young-Soo;Kim, Myeong-Soo;Kim, Man-Keon;Kim, Hyeog-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.65-77
    • /
    • 2006
  • There is not high level to fire number in stables, but if it were fire, there would be happened many property damage in a national or personal. We grasp safety awareness of a safety supervisor enforcing question survey of electric installation for national stables, and investigate use the actual condition of electric installment with a heating apparatus, a ventilating system, a distributing board, a wiring apparatus etc high fire dangerousness among electric installment using a stables I hope to make use of data to protect a electric fire submitted thesis.

  • PDF

Development of Electrical Safety Monitoring System for Conventional Markets (재래시장 전기안전 감시시스템 개발)

  • Lee, Sang-Ick;Kim, Gi-Hyun;Bae, Seok-Myung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.552-556
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of conventional markets is introduced the electric safety monitoring system which is suitable in conventional markets. Investigate the actual conditions about electrical equipment of conventional markets, electrical safety monitoring system was constructed. Electrical safety monitoring system to verify the performance of the experiment was to build a test bed. Research results will be used with the data for the reliability security of the electric safe system operation which follows in the conventional markets actual proof equipment construction which will be advanced.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Human Experimental Studies on the Risk of Electric Shock due to Damage of Underground Wire in Street Lamp (가로등의 지중전로 손상으로 인한 인체감전 위험성에 대한 실험 연구)

  • Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.6-12
    • /
    • 2009
  • This study performed an experiment for the danger of an electric shock in the human body, which is directly touched or approached to the exposure of buried metals in a leak caused by certain ground faults at a buried cable in street lamp. In the results of the experiment, the dangerous of electric shocks due to the earth specific resistance and wet and submersion of the earth surface represents a high level as the human body is directly touched to the buried metal at a leak point. In addition, it can be seen that the safety of the human body is influenced by the earth specific resistance, separated distance from buried metals, and shape of buried metals at around the leak point.

Properties of Electric Sofety for Dielectric Loss of Aging Natural Rubber. (노화된 천연고무의 유전손실에 관한 전기안전특성)

  • 이성일;권호영
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.5-12
    • /
    • 1991
  • The dielectric properties of natural rubbers for electric safety are very important to investigate the molecular structure. The electric safety characteristics of the dielectric absorption in aging vulcanized natural rubber were studied in the range of frequency from 1$\times$10$^3$[Hz]to 3.2$\times$10$^3$[Hz]l at the temperature of 23[$^{\circ}C$]. As the results, it has been confirmed that in the case of aging natural rubber of above 2 phr the specimens exhibit two kinds of dielectric losses due to the dipole polarization by impurities and sulfurs, and of raw rubber exhibit the kind of losses due to the dipole polarization. Rurthermore, dielectric loss maximum tansspectrum in high freguency region for electric safety, which removed to the low freguency according to increasing sulfur, depends greatly on sulfur.

  • PDF

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System (대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석)

  • Chae, Dong-Ju;Yi, Geon-Ho;Lim, Hyun-Sung;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

Electric malfunction research for safety of elevator system (승강기 시스템의 안전성을 위한 전기적 오동작 조사)

  • Lee, Hee-Tae;Kim, Jae-Chul;Kim, Gi-Hyun;Bae, Suk-Myong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.316-318
    • /
    • 2005
  • Increasing elevator system every year that is directly connected passenger's safety and connected peculiarity Reliability of each variety equipment that is composing elevator is linked with passenger's safely, and prevent accident is important. Malfunction by electric part of elevator system that is composing elevator is not easy to examine closely the cause. Estimation about malfunction of component by electric power quality must consist among them. In this paper, inspect elevator accident figure to examine effect that electric power quality gets on elevator that see and presented thing for research direction and necessity of electric safety consideration by such electric malfunction.

  • PDF

A Study on the Certification Criteria fot Personal Watercraft Using Electric Power Propulsion (전기 동력 추진식 수상오토바이 인증기준 개발 연구)

  • Kang, Dae-Kon;Kim, Shin-Hyo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.67-72
    • /
    • 2017
  • This study developed an electric power propulsion personal watercraft by combining a battery and an electric system from the domestic automobile industry with water motorcycle from marine leisure industry in a convergence of technology. It also developed a safety inspection plan and type approval standard for personal watercraft that use electric power propulsion. For the registration and production of the electric power PWC (Personal Watercraft), a safety inspection standard (draft) and type approval standard (draft) have been established. PWC that use this electric power propulsion certification standard have been divided into two categories according to the use of gasoline engines as related to the ship's electrical system. The contents of these safety inspections standards is divided into 7 categories, and their purpose is to confirm the facilities used for the safe operation of PWC. Type approval is divided into 7 categories and is intended to ensure the safe production of PWC. This is basic data can be used to establish criteria for safety inspection and type approval of electric power propulsion vessels and to guide the production of the environmentally friendly PWC in Korea.