• Title/Summary/Keyword: Electric safety

Search Result 1,827, Processing Time 0.032 seconds

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Reliability Optimization of Urban Transit Brake System For Efficient Maintenance (효율적 유지보수를 위한 도시철도 전동차 브레이크의 시스템 신뢰도 최적화)

  • Bae, Chul-Ho;Kim, Hyun-Jun;Lee, Jung-Hwan;Kim, Se-Hoon;Lee, Ho-Yong;Suh, Myung-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.26-35
    • /
    • 2007
  • The vehicle of urban transit is a complex system that consists of various electric, electronic, and mechanical equipments, and the maintenance cost of this complex and large-scale system generally occupies sixty percent of the LCC (Life Cycle Cost). For reasonable establishing of maintenance strategies, safety security and cost limitation must be considered at the same time. The concept of system reliability has been introduced and optimized as the key of reasonable maintenance strategies. For optimization, three preceding studies were accomplished; standardizing a maintenance classification, constructing RBD (Reliability Block Diagram) of VVVF (Variable Voltage Variable Frequency) urban transit, and developing a web based reliability evaluation system. Historical maintenance data in terms of reliability index can be derived from the web based reliability evaluation system. In this paper, we propose applying inverse problem analysis method and hybrid neuro-genetic algorithm to system reliability optimization for using historical maintenance data in database of web based system. Feed-forward multi-layer neural networks trained by back propagation are used to find out the relationship between several component reliability (input) and system reliability (output) of structural system. The inverse problem can be formulated by using neural network. One of the neural network training algorithms, the back propagation algorithm, can attain stable and quick convergence during training process. Genetic algorithm is used to find the minimum square error.

Calculation of Induced Current in the Human Body around 765 kV Transmission Lines (765 kV 초고압 송전선 주변의 인체 유도전류 계산)

  • 명성호;이재복;허창수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.802-812
    • /
    • 1998
  • Safety related to electric field exposure for the personnel of high voltage power plant and substation is of importance. To analyze the induced current influencing on human body in this paper, we calculate directly capacitance in three dimension which is complex and time consuming, as not to separate the voltage source and the induced object using a effective modeling technique. The proposed algorithm in this paper has been applied to 765 kV high voltage transmission line to evaluate human hazard for the induced current through the case study. As the results, the short circuit current of human body has been identified in the range of 0.3 mA to 6.8 mA. Closing to transmission line, this range of short current can exceed 5 mA that ANSI recommended let-go current. Therefore, it is necessary to countermeasure such as putting on conductive clothing in live-line maintenance of transmission line.

  • PDF

Electrochemical Properties of LiMn2O4-LiNi1/3Mn1/3Co1/3O2 Cathode Materials in Lithium Secondary Batteries (리튬이차전지 양극활물질용 LiMn2O4-LiNi1/3Mn1/3Co1/3O2의 전기화학적 특성)

  • Kong, Ming Zhe;Nguyen, Van Hiep;Gu, Hal-Bon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.298-302
    • /
    • 2016
  • In this work, $LiMn_2O_4$ and $LiNi_{1/3}Mn_{1/3}Co_{1/3}O_2$ cathode materials are mixed by some specific ratios to enhance the practical capacity, energy density and cycle performance of battery. At present, the most used cathode material in lithium ion batteries for EVs is spinel structure-type $LiMn_2O_4$. $LiMn_2O_4$ has advantages of high average voltage, excellent safety, environmental friendliness, and low cost. However, due to the low rechargeable capacity (120 mAh/g), it can not meet the requirement of high energy density for the EVs, resulting in limiting its development. The battery of $LiMn_2O_4-LiNi_{1/3}Mn_{1/3}Co_{1/3}O_2$ (50:50 wt%) mixed cathode delivers a energy density of 483.5 mWh/g at a current rate of 1.0 C. The accumulated capacity from $1^{st}$ to 150th cycles was 18.1 Ah/g when the battery is cycled at a current rate of 1.0 C in voltage range of 3.2~4.3 V.

Technical Trends for Small Aircraft Propulsion (소형항공기 추진기관 기술동향)

  • Kim, Keun-Bae
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.35-43
    • /
    • 2008
  • Technical trends of propulsion system for small aircraft are investigated. Currently, most small aircraft are equipped with piston engine, turboprop and turbofan engines, and the technology development is going continuously. For piston engines, new diesel engines are arising besides gasoline engine. The diesel engines use relatively low-cost and easy to get fuel(Jet A), so the demand for small aircraft is getting increased, and new engines with high reliability and efficiency are being developed. For gas turbine engines, application of small turbofan is getting increased for newly arising VLJ market and the engine demand will be rapidly increased in the future. On the other hand, some electric propulsions without fossil fuels are being developed without high cost of fuel and environmental effects. In the future, propulsion system for small aircraft will be developed having enhancement of performance and efficiency with higher reliability and safety.

  • PDF

Research of Electrical Safety Test Construction about Structure under 765kV Transmission Lines (765kV 송전선로 선하 건조물 전기안전 실증시험 구축 연구)

  • Mun, Seong-duk;Maeng, Jong-ho;An, Ho-sung;Ahn, Heesung;Lee, Ho-guen
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.410-411
    • /
    • 2015
  • 765kV 송전선로와 선하 건조물은 최하단 도체의 높이 28m를 적용하고 대지저항률은 $100{\Omega}m$, IEEE 변전소 설계지침인 Std-80에 따라 건조물에 접촉하는 사람의 인체저항은 $1000{\Omega}m$, 대지를 딛고 있는 사람의 한쪽 발 접지저항은 직경 8cm의 원판 접지저항을 적용한다. 이렇게 구성된 모델에서 선로중심에서 건조물까지 이격거리 변동에 따라 인체 유도전류를 측정하고자 한다. 본 연구에서는 전기안전 실증시험을 위해 765kV 가공송전선로 직하에 목조 및 샌드위치 판넬 2가지 시험용 가옥을 설치하였다. 전기설비기술기준에 의거하여 선하직하 이격거리가 28m일 때 발생할 수 있는 전자계 특성과 재질에 따른 전자계가 미치는 영향을 비교 분석하고 장기 유도장해 실측 데이터를 확보하고자 그림 1과 같이 구축 설계하였다. 이를 통해 송전선로에 의해 선로중심으로부터 구축된 모의가옥까지 이격거리에 따라 유도되는 전류를 측정하고 그 크기가 인체에 미치는 유도전류 한계치 초과 여부에 대해 검토함으로써 안전성 여부에 대해 측정 및 검토하고자 시험게획을 수립하였다. 또한 선로 고장 시 대지전위상승에 의한 선하 건조물 안정성 검토 및 낙뢰서지 유입에 의한 전기안전 시험 구성을 하였다.

  • PDF

Assess of Breakdown Characteristics about Environmentally Friendly Gases (친환경절연재의 절연성 평가)

  • Choi, Eun-Hyeok;Koo, Bon-Ho;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.96-100
    • /
    • 2009
  • With the improvement of industrial society, the high quality electrical energy, simplification of operation and maintenance, ensuring reliability and safety are being required. This paper compares breakdown characteristics in $SF_6$ gas with $N_2/O_2$ Mixture gas($N_2:O_2=100$ : 0, 79 : 21, 60 : 40, 40 : 60) as using widely in High Voltage insulation equipment with the characteristics in different media which are focused on environmentally friendly gases. As an append result of research the results are fundamental data for electric insulation design of Distribution Power Facilities which will be studied and developed in the future. And we could make an environment friendly gas insulation material with mataining dielectric strength by $N_2/O_2$ Mixture gas which generates a lower lever of the global warming effect.

Comparison of characteristics between cam and electric control type of 2 stroke diesel engine for ship propulsion (캠 및 전자제어식 선박추진용 저속 2행정 디젤엔진의 성능 비교)

  • Lee, Sang Deuk;Jung, Suk Ho;Koh, Dae Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.849-854
    • /
    • 2013
  • Many researches on green ship with increasing on economics, efficiency and convenience have been carried out consistently. One of them is development of diesel engines with electronic control. While small duty one for automobiles had been adopted mainly already, disseminating heavy duty one for ships has trouble due to safety and reliability. In order to solve these problem in this study, performance of electronic control and cam type engine installed in parallel on training ship HANBADA of korea maritime university was analyzed and compared. It is certain that specific fuel oil consumption of the electronic control type is lower than cam type and excellent at lower engine load, especially. And the electronic control type shows more effective characteristic at sea trial on specific fuel oil consumption.

Effect of Center Pin in Free Fall Test for a Cylindrical Li-ion Cell (원형 리튬 전지의 센터 핀이 낙하 충격에 미치는 영향)

  • Kim, Simon;Lee, Young Shin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.639-644
    • /
    • 2015
  • A cylindrical secondary Li-ion cell is a device in which stored chemical energy is converted to electrical energy via an electrochemical reaction. These cells are widely used for applications that require high capacity and rate power, such as notebooks, power tools, and electric vehicles. The role of a center pin is to retain the channel for gas release, preventing blockage of the hollow of the jelly roll during a charge-discharge cycle, and to prevent an internal short circuit for tearing of separator under mechanical free fall. In this paper, two experiments are conducted with and without the center pin to experimentally verify the importance of the role of the center pin. The first experiment is a 50-cycle charge-discharge cycle test, and the second is a free fall test conducted according to the Underwriters Laboratories (UL) standards. Based on these experiments, we demonstrate that the center pin in a cylindrical cell is a very important component in terms of safety.