• Title/Summary/Keyword: Electric railway system

Search Result 773, Processing Time 0.031 seconds

Torque Distribution Algorithm of Independent Drive Articulated Vehicle for Small Radius Turning Performance (독립 구동 굴절차량의 회전반경 감소를 위한 토크분배 알고리즘)

  • Lee, Kibeom;Hwang, Karam;Tak, Junyoung;Suh, In-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.336-341
    • /
    • 2014
  • The articulated structures seen in train or tram applications are being applied in road transportation systems, for use in mass passenger transit. When articulated vehicles are driven on public roads, they no longer follow a guided track. Therefore, there are a lot of control elements that need to be considered, such as turning radius, swept path width, off-tracking, and swing-out. Some of the currently available articulated vehicles on roads are equipped with an independent drive system; a system that has one motor at each wheel. Through this drive system, each wheel can be independently controlled, making precise and quick dynamic stability control possible. In this paper, we propose a torque distribution algorithm that can reduce the overall turning radius of the articulated vehicle, which has been verified through dynamic simulation.

The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Ahn, Jeong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

Comparative LCA of three types of Interior Panel(IP) in Electric Motor Unit(EMU) (전동차 내장패널(Interior Panel)에 대한 비교 전과정평가)

  • Choi, Yo-Han;Lee, Sang-Yong;Kim, Yong-Ki;Lee, Kun-Mo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.584-588
    • /
    • 2007
  • A comparative Life Cycle Assessment(LCA) among three types of Electric Motor Unit(EMU) Interior Panel(IP) was conducted. A functional unit for comparative LCA is a weight of IP for 1 EMU. It assumed that Manufacturing stage and its upstream processes, Use stage and End of Life(EoL) stage are included in the boundary of product system. For Use stage, the weight of IP causes electricity consumption. It is assumed that aluminum IP is recycled and the other IPs are incinerated at the EoL stage. As comparison results, aluminum IP has much larger environmental impact(5.162pt) than others(FRP IP; 4.069pt, Phenol IP; 4.053pt) even though recycling consideration is included. The manufacturing stage of aluminum has relative big envrionmental impact(1.824pt) and this point make the most important difference from other IPs(FRP IP; 0.1617pt, Phenol IP; 0.4534pt)). Despite of large weight difference between FRP IP(888.56Kg) and phenol IP(315Kg), the final environmental impact result has only little difference(0.016pt, 0.39%). With this result, the EMU designer can choose IP with a consideration of the environmental performance of IP.

  • PDF

Development of Permanent Magnet Synchronous Motor for High-speed Electric Multiple Unit - 400km/h eXperimen (차세대 고속전철용 영구자석동기 전동기 개발)

  • Kim, Jung-Chul;Kim, Bong-Chul;Park, Yeong-Ho;Kim, Chul-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.470-474
    • /
    • 2010
  • Up until now, power centralized trains have been produced due to the maintenance convenience and comfortableness, but there are some problems, such as limitation of viscosity and maintenance difficulty of railroad due to recently increasing axle mass. In order to improve the problems, power decentralized trains have been developed to improve traction power. In the case of using electrical braking system, it is possible to improve braking friction power. Induction motors have been developed for power decentralized high speed train because of less structural defection, and low maintenance and production cost. However, induction motors have limitations, such as assuring enough power capacity and efficiency with reduced size. PMSM (Permanent magnet synchronous motor) have been newly developed to improve shortcomings of induction motors. The PMSM can be produced small and light weighted. Also if the PMSM and induction motors have the same size and power capacity, the PMSM have better power efficiency. In this pater, the prototype and modified type of PMSM for "High-speed Electric Multiple Unit-400km/h eXperimmen" will be introduced.

  • PDF

The Development of IGBT Type 190kVA Static Inverter for Electric Car (전동차용 IGBT형 190kVA 보조전원장치 개발)

  • Kim, J.K.;Park, G.T.;Jung, K.C.;Kim, D.S.;Seo, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.634-637
    • /
    • 1997
  • This paper is on the research and development of new SIV(Static Inverter) using IGBT(Insulated Gate Bipolar Transistor) semiconductor for a wide range of electric railway applications. For the simplification and higher controllability, the direct PWM control method with 3level inverter topology was adopted. In the new SIV system, the cost as well as bulk and weight was appreciably reduced about 40% lower than those of conventional SIV, the electrical efficiency was increased above 95% and the audible noise level was less than 65dB. In addition, the THD(Total Harmonic Distortion) factor was below 5% and the voltage fluctuation on a transient state was below 10%.

  • PDF

A Study on the Uplift for Applying of Heavy Simple Catenary System in a Overhead Rigid Conductor Rail Transition Section (강체전차선로 이행구간 Heavy Simple Catenary 적용을 위한 압상량 고찰)

  • Kim, Wan-il;Park, Weon-Chan;Lee, Jae-Bong;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.688-694
    • /
    • 2018
  • The transition section of the overhead rigid conductor rail (ORCR) consists of a direct induction device and a limit point to prevent the power supply failure and failure of the electric railway vehicle pantograph due to the difference of the uplift in the catenary line. In T-Bar transition section, a twin simple catenary is mostly installed between the overhead catenary system (OCS) in the ground section and the ORCR in the underground section. In this paper, we compare and analyze the possibility of replacing the twin simple catenary with heavy simple catenary. The reliability of numerical analysis results was confirmed by comparing field test with numerical results. Comparing the numerical results of the twin simple catenary with the heavy simple catenary in the transition section, the difference uplift is 5.9[mm] on average. When applying heavy simple catenary instead of twin simple catenary, the slight difference of uplift can be compensated by adjusting the height of hanger-ear or support bracket.

A Study on the RAM Application of a Light Rail Transit Business, Ac-cording to the Technique Application in System Engineering (시스템엔지니어링 기법 적용에 따른 경량전철사업의 RAM적용에 관한 고찰)

  • Lee, Seong-Gwon;Min, Kyong-Se;Jeon, Seo-Tak;Jung, Kye-Young
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.13-19
    • /
    • 2011
  • A LRT(Light Rail Transit) is one of the Future Urban Railway Development Project. The project's goal is to reduce a transportation congestion in the center of the city. New transportation is intensely required in order to overcome a limit of the ground transportation that is the existing public transportation, A LRT(Light Rail Transit) construction project to be based on an unmanned driving system is the large composition system that a vehicle, a signal, communication, electric, track etc. were organically integrated as echo-friendly urban transportation systems. It also put a huge budget, which is a large-scale infrastructure projects. It is international trend that Light Rail Transit projects apply a technique in System Engineering for a schedule, cost, quality elevations, and to approach in viewpoints of life-cycle from initial construction steps to operation, abolition. This paper intends to analyze RAM requirements taking into consideration ISO/IEC 15288 throughout life-cycle from concept, design, manufacture, operation and maintenance to the final phase, decommissioning, and the study seeks to suggest directions of efficient use to domestic LRT projects.

Towards the Application of Safety Integrity Level for Improving Process Safety (공정안전향상을 위한 Safety Integrity Level의 적용 방향)

  • Kwon, Hyuck-Myun;Park, Hee-Chul;Chun, Young-Woo;Park, Jin-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

A study on the efficient operation program of digital protection relay in DC feeder system (DC 급전계통의 디지털 보호계전기의 합리적 운용방안 검토)

  • Lee, Kyung-Goo;Hyun, Yong-Sub;Hong, Sung-Lae;Baek, Jae-Woo;Min, Yong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.946-958
    • /
    • 2009
  • Lately, Seoul metro is changing transformation facilities which have been operated in subway line 1 and 2 for a long duration of time. Although the exiting protection relays in DC feeder system have such several functions as 76I, 50, 85, and 64P, the new protective relay have a great variety of functions such as 76I, 76D, DDL-I, DDL-T(Imin), 85, and 64P, as well as record and save various events and accident wave in order to review and analyze the working causes of the protective system. However, because the new digital relays are not used properly for protective propose, there are the cases that the electric accident is deteriorated more. Therefore, in this paper, we will describe that making the use studying installation intention, direction, and setting up value of the protection relay in DC breaker operation not only prevents from making the electric accident worse but also shows the efficient operation method of direct current protection system.

  • PDF