• Title/Summary/Keyword: Electric quality

Search Result 1,434, Processing Time 0.032 seconds

Study on the Oversea Technology Development of Electric Power Storage System and It's Domestic Application (전력저장시스템 기술개발 국외동향 분석 및 국내 활용방안 연구)

  • Choi, Kyung-Shik;Yang, Seung-Kwon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • As the technology of a large scale battery have advanced, it's application to the electric power network have been active in foreign country. By providing the electric power energy stored in the electric power storage system when needed, there are many advantages that it is able to reduce the gap between the electric power demand and supply for day and night to increase capacity factor, to upgrade the electric power quality degraded from the unbalance between power demand and supply and to compensate the fluctuation of wind power plant and photovoltaic power generation. In this study, the current application of electric power storage system using battery is introduced in detail, and I have thought out it's application fields based on the foreign examples. These are demand side response, upgrade of the power quality, stabilization of fluctuation of renewable energy and distributed generation for filling elapse.

  • PDF

A Malfunction Pattern Distinction of an Automotive Electric part by Sound and Vibration Frequency Analysis (소음진동 주파수분석을 이용한 자동차 전동부품의 고장유형 분석)

  • Sim, Han-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.107-112
    • /
    • 2021
  • The usage of electric-powered components consisting of several electrical and mechanical parts is continuously increasing in automobiles. Therefore, continuous assessment of the reliability and quality of these electric-powered parts is crucial. In this study, a noise and vibration measurement system for testing and evaluating the different electric-powered parts of automobiles was designed. Further, an FFT analysis was performed on some electric-powered steering assembly test equipment. In the FFT analysis of the noise and vibration signals for each essential fault part, the vibration FFT analysis was significantly compared with the noise analysis. The results showed that the vibration FFT analysis was more effective in determining the reliability and quality of the electric-powered parts.

Automatic Algorithm for Cleaning Asset Data of Overhead Transmission Line (가공송전 전선 자산데이터의 정제 자동화 알고리즘 개발 연구)

  • Mun, Sung-Duk;Kim, Tae-Joon;Kim, Kang-Sik;Hwang, Jae-Sang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.73-77
    • /
    • 2021
  • As the big data analysis technologies has been developed worldwide, the importance of asset management for electric power facilities based data analysis is increasing. It is essential to secure quality of data that will determine the performance of the RISK evaluation algorithm for asset management. To improve reliability of asset management, asset data must be preprocessed. In particular, the process of cleaning dirty data is required, and it is also urgent to develop an algorithm to reduce time and improve accuracy for data treatment. In this paper, the result of the development of an automatic cleaning algorithm specialized in overhead transmission asset data is presented. A data cleaning algorithm was developed to enable data clean by analyzing quality and overall pattern of raw data.

The Effect of Quality Management System and Absorptive Capacity on the Competitiveness of Small and Medium Venture Manufacturing Company in Electric and Electronic Industry (품질경영시스템과 흡수역량이 전기전자분야 중소벤처 제조기업의 경쟁력에 미치는 영향)

  • Jin, Sung-Han;Lee, Cheol-Gyu;Lee, Dong-Myung
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.2
    • /
    • pp.292-304
    • /
    • 2011
  • This study is to search for the core factors of improving competitiveness of small and medium venture manufacturing company in electric and electronic industry and to do an in-depth analysis of the relations with management performance through systematic approach and to provide implications of importance of the management for the improvement factors for the domestic small and medium venture manufacturing company in electric and electronic industry. The report is analyzed how the relationship between the quality management system that was discussed in existing literature and the core factors of absorbing capability impact to the enterprise management performance.

Growth of ZnO Nanorod with High-quality Assisted by an External Electric Field (외부 전계 인가를 통한 고품질 ZnO 나노로드 성장)

  • Son, Min-Kyu;Seo, Hyun-Woong;Kim, Soo-Kyoung;Hong, Na-Yeong;Kim, Byung-Man;Park, Song-Yi;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1641-1645
    • /
    • 2012
  • In this study, the ZnO nanorod is grown on the seed layered glass substrate by applying an external electric field to fabricate the ZnO nanorod with the high quality and to increase the yield of the ZnO nanorod. It is possible to grow the definite and clear hexagonal ZnO nanorod as the cathode of the high voltage is connected to the side of the seed layered glass substrate and the anode is connected to the opposite side because more $Zn^{2+}$ ions are located around the ZnO seed layer and are accumulated easily due to the external electric field. As a result, it is succeeded to fabricate the definite hexagonal ZnO nanorod having better structural characteristics by applying the external electric field during the growth process. Therefore, it is demonstrated that the external electric field is effective to fabricate the high quality ZnO nanorod without changing any composition of the ZnO nanorod.

Localization Developments on Electric Igniter for Thermal Battery of a Missile on K-PSAM (신궁 장입유도탄 열전지용 전기식 착화기 국산화 개발)

  • Ahn, Mahn-Ki;Jeon, Jae-Hyun;Ahn, Gil-hwan;Lee, Seung-Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.536-542
    • /
    • 2017
  • In this paper, authors described on localization development's results about an electric igniter in thermal battery with a pyrotechnic heat sources. Especially, the development test and evaluation(DT&E) process and the methods in the developments of the electric igniter which is parts of a domestic thermal battery on K-PSAM was in charge of government and developed for defense of a local areas in Korea. We have proposed a process of design and manufacture on the electric igniter. Finally, we verified a quality and a reliability of the electric igniter from test results by Fisher-Snedecor's law and over 99.5 %(C.L. 95 %) for K-PSAM.

The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality (순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구)

  • Park, In-Deok;Jeong, Sung-Won;Gim, Jae-Hyeon;Lee, Geun-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

Single-phase Cascaded H-bridge Multilevel Active Power Filters in AC Electric Railway Systems

  • Wu, Liran;Wu, Mingli
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.788-797
    • /
    • 2017
  • The power quality of AC electric railways has become an issue worthy of more and more concern. Many active compensators based on power converters have been proposed, but with complex transformers or coupled branches. This paper presents a single-phase cascaded H-bridge multilevel active power filter (APF), which can directly connect to the 27.5-kV power supplies to deal with power quality problems. According to field measured data, the load characteristics are analyzed, and the system configuration and control system are designed based on the load characteristic analysis. Finally, simulation and experimental results verify the effectiveness of the proposed APF system, considering some problems such as the supply voltage fluctuations and transient inrush currents in AC electric railway systems.