• Title/Summary/Keyword: Electric potential distribution

Search Result 211, Processing Time 0.024 seconds

A study on the association between electric toothbrush use on calculus formation and periodontal tissue condition in Korean adults: 7th Korea National Health and Nutrition Examination Survey (우리나라 성인의 전동칫솔 사용이 치석 형성 치주조직 상태에 미치는 영향: 제7기 국민건강영양조사 자료 활용)

  • So-Hyeon Lee;Ha-Young Ahn;Yun-Sook Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.343-352
    • /
    • 2024
  • Objectives: This study aimed to assess the relationship between electric toothbrush use and the presence of community periodontal index (CPI) code calculus among Korean adults. Methods: Data from the 7th Korea National Health and Nutrition Examination Survey were analyzed. Multiple logistic regression analysis with a complex sampling design was conducted, adjusting for general characteristic factors. Analyses were performed using SPSS Statistics 29.0. Results: Among the participants, the prevalence of electric toothbrush users was 5.3%. Within this group, 4.7% had periodontal disease, whereas 5.9% did not (p=0.025). Even after adjusting for general characteristics factors in model II of electric toothbrush use, the odds ratio remained statistically significant at 0.791 (95% CI: 0.631-0.992) in all cases. Conclusions: Electric toothbrush use appears to be associated with potential benefits in managing the CPI code calculus distribution; however, evidence supporting this notion remains insufficient. The study findings suggest that these results could be a basis for future studies related to oral hygiene products and the design of oral health promotion programs.

Transient Grounding Impedance Characteristics of a Concrete Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 콘크리트봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Kim, Jong-Uk;Lee, Kyu-Jin;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The grounding impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A concrete rod electrode is one of the commonly used grounding electrodes in electric distribution systems. In this paper, the grounding impedance of concrete rods has been measured in frequency raging from 60[Hz] up to 100[kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

Transient Grounding Impedance Characteristics of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems Using EDSA Program (EDSA 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Kim, Min-Sung;Choi, Jong-Kee;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.26-32
    • /
    • 2009
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A copper rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the grounding impedance of copper rods has been measured in frequency raging from 60[Hz] up to 100 [kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

Stress Measurement of Structural Member Using Piezoelectric Property (압전 특성을 이용한 구조물 부재의 응력측정)

  • Im, Eun Sang;Kim, Tea Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.103-108
    • /
    • 2007
  • A stress measurement method of structural member using piezoelectric property and electrostatic voltmeter is presented. The electric potentials of the surface of the piezoelectric element, which are proportional to the strain ${\varepsilon}$ on the structural member, are measured by an electrostatic voltmeter during load cycling. The stress ${\sigma}$ is calculated by this strain ${\varepsilon}$. Moreover, a stress distribution measurement tape which can be used for the stress distribution measurement along a specified line on the surface of structural member is developed, and the surface potential was measured by an electric static voltmeter of non-contact type. The applicability of the stress distribution measurement tape is examined through experiments using a notched specimen under cyclic loading. The measured distributions of x, y and xy are compared with those calculated by FEM analysis.

A Study on the Characteristic of Twisted Nematic Liquid Crystal Cell by Three Dimensional Finite Element Method (3차원 유한요소법을 이용한 TN 모드 액정 셀 특성 분석 연구)

  • 정주식;윤상호;이철수;윤석인;원태영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.12
    • /
    • pp.1071-1079
    • /
    • 2002
  • This paper reports a methodology and application lot calculating distribution of the director in a liquid crystal cell by a numerical technique. To calculate distribution of the director, we applied a three dimensional finite element method (FEM) and calculated the distributions of electric potential and director in the liquid crystal cell. We have considered the free-energy density in the bulk of liquid crystal cell and calculated the switching property by the Ericksen-Leslie equation and the Laplace equation. We have calculated the optical transmission with distribution of the director by Berreman's method and confirmed the threshold voltage and the response time.

A Study on the Power Management Algorithm of Centralized Electric Vehicle Charging System (중앙제어기반 전기자동차 충전시스템의 에너지관리 알고리즘에 관한 연구)

  • Do, Quan-Van;Lee, Seong-Joon;Lee, Jae-Duck;Bae, Jeong-Hyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.566-571
    • /
    • 2011
  • As Plug-in Hybrid Vehicle and Electric Vehicle (PHEV/EV) take a greater share in the personal automobile market, their high penetration levels may bring potential challenges to electric utility especially at the distribution level. Thus, there is a need for the flexible charging management strategy to compromise the benefits of both PHEV/EV owners and power grid side. There are many different management methods that depend on the objective function and the constraints caused by the system. In this paper, the schema and dispatching schedule of centralized PHEV/EV charging spot network are analyzed. Also, we proposed and compared three power allocation strategies for centralized charging spot. The first strategy aims to maximize state of vehicles at plug-out time, the rest methods are equalized allocation and prioritized allocation based on vehicles SoC. The simulation results show that each run of the optimized algorithms can produce the satisfactory solutions to response properly the requirement from PHEV/EV customers.

Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System (비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2619-2627
    • /
    • 2009
  • The ground fault is occupying 70% among the total number of faults in ungrounded distribution power system. When the ground fault occurs in ungrounded system, the fault current is so small that it is hard to detect. But fault handling is very important because to continue power supply during fault conditions may cause the fault spreading and the distribution device in trouble. This paper presents the fault line detection method by using GPT signal detecting zero sequence voltage, and the fault section detection method by detecting whether GPT signal is disappeared or not during shifting normally open switch, which is connecting switch between distribution lines with open state in order to restore the outage area under emergency situation, and during isolating each section one by one which belongs to the fault line. This method is efficient because there is no whole power interruption during the fault section detection, and it is possible to perform both the fault section detection and the service restoration for the outage area at the same time, and it can apply to various distribution system configuration. Program for the fault restoration was developed applying proposed method, and it has been validated by applying to the pilot project of distribution automation system in Vietnam which has the ungrounded distribution system.

Mechanical behaviors of piezoelectric nonlocal nanobeam with cutouts

  • Eltaher, Mohamed A.;Omar, Fatema-Alzahraa;Abdraboh, Azza M.;Abdalla, Waleed S.;Alshorbagy, Amal E.
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.219-228
    • /
    • 2020
  • This work presents a modified continuum model to explore and investigate static and vibration behaviors of perforated piezoelectric NEMS structure. The perforated nanostructure is modeled as a thin perforated nanobeam element with Euler-Bernoulli kinematic assumptions. A size scale effect is considered by included a nonlocal constitutive equation of Eringen in differential form. Modifications of geometrical parameters of perforated nanobeams are presented in simplified forms. To satisfy the Maxwell's equation, the distribution of electric potential for the piezoelectric nanobeam model is assumed to be varied as a combination of a cosine and linear functions. Hamilton's principle is exploited to develop mathematical governing equations. Modified numerical finite model is adopted to solve the equation of motion and equilibrium equation. The proposed model is validated with previous respectable work. Numerical investigations are presented to illustrate effects of the number of perforated holes, perforation size, nonlocal parameter, boundary conditions, and external electric voltage on the electro-mechanical behaviors of piezoelectric nanobeams.

A study of dielectric strength and insulating property for particle contamination Under SF6/N2 Mixture (혼합가스의 이물 존재시 절연 특성 연구)

  • Jeong, Dong-Hoon;Woo, Su-Youl;Seo, Kyoung-Bo;Kim, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1262-1263
    • /
    • 2011
  • Sulfur hexafluoride is the most commly used insulation gas in electrical systems. Gas insulated systems are widely used in the electric power industry for transmission and distribution of electrical energy. When $SF_6$ was first discovered, the potential application was only considered for insulation because of good dielectric properties. But the widespread use of $SF_6$ gas by electric power and other industries has led to increase concentrations of $SF_6$ gas in the atmosphere. This concern as to possible effects on global warming because $SF_6$ is a potent greenhouse gas. That's why firstly we studied uniform and nonuniform field property by mixing $SF_6$ and N2 gas. This paper presents the dielectric strength and insulating property for particle contamination under $SF_6/N_2$ mixtures. Two types of mixed gases(50% $SF_6$_50%$N_2$, 20% $SF_6$_80%$N_2$) were applied. We performed tests for the length and shape of particle. Test gas pressure is from 0.3 to 0.7 Mpa. The study was conducted to develop environment-friendly insulating material for GIS that can reduce $SF_6$ gas and make a design criteria for mixtures.

  • PDF

A Study on Relationship Between Discharge Voltage and Plasma Characteristics of Hall Thruster Using a Hybrid Model (하이브리드 모델을 이용한 홀 추력기의 방전 전압과 플라즈마 특성 관계 연구)

  • Jung, Gwanyong;Sung, Hong-Gye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.8
    • /
    • pp.611-620
    • /
    • 2020
  • The effect of discharge voltage on electron mean energy, electric potential, ionization rate, neutral and ion density of Hall thruster was analyzed using a two-dimensional axisymmetric hybrid model. The results of the code developed for this study such as discharge current, thrust, and plasma distribution according to discharge voltage of SPT-100ML Hall thruster were compared by experiments and calculations of other researchers for validation. The results show that the electron mean energy, the ionization rate, and the ion density are increased while the neutral density is decreased as the discharge voltage is increased. The thrust and the discharge current are proportional to the discharge voltage.