• Title/Summary/Keyword: Electric noise

Search Result 1,035, Processing Time 0.026 seconds

The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator (3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석)

  • 김재열;김우진;심재기;김영석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

Electric Vehicle Wireless Charging Control Module EMI Radiated Noise Reduction Design Study (전기차 무선충전컨트롤 모듈 EMI 방사성 잡음 저감에 관한 설계 연구)

  • Seungmo Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.104-108
    • /
    • 2023
  • Because of recent expansion of the electric car market. it is highly growing that should be supplemented its performance and safely issue. The EMI problem due to the interlocking of electrical components that causes various safety problems such as fire in electric vehicles is emerging every time. We strive to achieve optimal charging efficiency by combining various technologies and reduce radioactive noise among the EMI noise of a weirless charging control module, one of the important parts of an electric vehicle was designed and tested. In order to analyze the EMI problems occurring in the wireless charging control module, the optimized wireless charging control module by applying the optimization design technology by learning the accumulated test data for critical factors by utilizing the Python-based script function in the Ansys simulation tool. It showed an EMI noise improvement effect of 25 dBu V/m compared to the charge control module. These results not only contribute to the development of a more stable and reliable weirless charging function in electric vehicles, but also increase the usability and efficiency of electric vehicles. This allows electric vehicles to be more usable and efficient, making them an environmentally friendly alternative.

Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line (±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가)

  • Woo, Jeong Min;Ju, Mun-No;Shin, Koo Yong;Kwon, Gu Min;Choi, Woo Jung;Lee, Jae Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

An Experimental Study on the Interior Noise for Passenger and Power cars (객차 및 동력차 실내소음에 관한 실험적 연구)

  • 문경호;유원희;김재철
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.150-156
    • /
    • 2000
  • The purpose of this paper is to evaluate the noise level and the noise source for domestic trains. We measured and analyzed the interior noise, the rolling noise and the engine noise at Honam line(Seodaejeon-Jangseong) for passenger and power cars. The noise level is below 69㏈A for Seamaeul PMC(Powered Motor Car) coachs, below 65㏈A for Seamaeul and Mukungwha coachs, over 80㏈A for the driver's room of PMC and diesel-electric locomotives.

  • PDF

Towards reducing acoustical high-frequency noise of a direct current relay via contact structure (직류 계전기의 접촉구조에 의한 고주파수 소음저감)

  • Junhyeok, Yang;Jongseob, Won;Wonjin, Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.691-697
    • /
    • 2022
  • In this work, a straightforward component design of a direct current (DC) relay equipped in electric vehicles is discussed. The work aims to provide and evaluate effective measures for reducing high-frequency sound from the DC relay carrying electric power. From the operation experiments for the relay, it is observed that noise is caused by the resonance from the forced vibration by the electromagnetic repulsive force originating at the area of electric contacts with a resonance frequency of around 710 Hz ~ 730 Hz. A finite element model for the relay was established to conduct vibration mode analysis, consisting of stationary and movable contacts and a contact spring. Vibration mode analysis indicates that in the resonance frequency, the movable contact with two-point contacts experiences rotational vibration mode. For the proposed relay with a three-point contact, vibration mode analyses give reasonable results of reducing noise at that frequency. Furthermore, for the fabricated relays with the three-point contact, similar results have been obtained. In conclusion, one can see that the proposed measures provide one of the feasible solutions to the reduction of relay noise.

Environmentally Friendly Design Program for HVAC Overhead Transmission Lines (HVAC 가공 송전선로 환경친화설계프로그램 TLCALC)

  • Yang, Kwang-H.;Ju, Mun-N.;Myung, Sung-H.;Shin, Koo-Y.;Lee, Sung-D.;Lee, Dong-I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.67-70
    • /
    • 2005
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient. TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

Development of an Environmental Friendly Design Program for HVAC Overhead Transmission Lines (HVAC 가공 송전선로 환경친화설계프로그램 개발)

  • Yang, Kwang-H.;Ju, Mun-N.;Myung, Sung-H.;Shin, Koo-Y.;Lee, Sung-D.;Lee, Dong-I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.469-471
    • /
    • 2002
  • HVAC transmission lines must be designed to satisfy environmental regulations. Therefore it is necessary to pre-evaluate environmental problems for transmission line designer using prediction program. In this study, environment design software, TLCALC 2001 for transmission lines was developed as a comprehensive window program. It has 6 modules that are audible noise, radio noise, television noise, magnetic field, electric field and conductor surface gradient TLCALC 2001 solved a few problems in use of the existing foreign tools and took several advantages. Experienced designers can get the results of calculation within about 15 minutes. Because the use of TLCALC 2001 is easy and practical, this program will be usefully applied to the environmental friendly design and construction of HVAC transmission lines. In the future, it is expected that public complaints and social environmental cost will be reduced by the use of TLCALC 2001.

  • PDF

Improvement of sound insulation performance of windows according to the specifications of the external electric blinds (외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과)

  • Min-Woo, Kang;Hee-Dong, Lee;Yang-Ki, Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.621-628
    • /
    • 2022
  • The most realistic way to reduce noise outside the building, such as road traffic noise and aircraft noise, is to strengthen the sound insulation performance at the sound collecting points such as balconies, windows, and exterior walls of each building. However, in light of the reality that shading devices outside buildings are not yet widely used, there are not many studies on sound insulation performance improvement using external windows and window devices such as louvers and blinds. In particular, external blinds can not only block the inflow of strong sunlight in the morning and evening from the outside of the building, but also target the sound insulation effect that blocks the peak noise that occurs during commuting hours. In this study, a study was conducted to improve sound insulation performance against external noise by using an external electric blind (EEB), which is one of the most efficient window and door external shading devices. Various sound insulation performance tests were conducted while changing the configuration of external electric blinds developed for light blocking purposes. Through this, it was verified that an additional sound insulation performance of 6 dB can be obtained by installing an external electric blind compared to the reduction performance of general windows.

Noise Lowering for a Large Variable Speed Range Use Permanent Magnet Motor by Frequence Shift and Structural Response Evaluation of Electromagnetic Forces

  • Arata, Masanori;Takahashi, Norio;Fujita, Masafumi;Mochizuki, Motoyasu;Araki, Takashi;Hanai, Takashi
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2012
  • According to electrical output up rating of a permanent magnet motor and request to operate for a large variable speed range, resonance between structural natural vibration and electromagnetic force inside the motor can take place and make noise. This paper describes the mechanism of a resonance between them and noise lowering procedure by frequency shift when they are applied to the reluctance torque largely employed new motor named Permanent magnet Reluctance Motor (PRM).

Environmental effects by corona discharge from a 765kV double circuit transmission line (765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF