• Title/Summary/Keyword: Electric measurement

Search Result 1,649, Processing Time 0.034 seconds

The Effects of the Electric Power Demand for Each Loads Based the Electric Power Demand Elasticity (전력수요 탄력성에 따른 각 용도별 부하의 전력수요 영향)

  • Kim, Mun-Yeong;Baek, Yeong-Sik;Song, Gyeong-Bin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.12
    • /
    • pp.568-574
    • /
    • 2001
  • The variations of real time electric power price in competitive electricity markets have influence on electric power demands of the consumers. The effects of the consumers for electric power price can be expressed the price elasticity coefficient of the power demand as a measurement. Residential, commercial, and industrial consumers with different characteristics cause the different price elasticity of the power demand due to changing the pattern of consumption. It is necessary that the effects of electric power demands as a function of elasticity coefficient for each loads should be analyzed in Korea which is processing deregulated electric market. Therefore, this paper calculate the elasticity coefficient of each loads and analysis the effects of electric power demands as a function of elasticity coefficient of inflexible and flexible consumers in competitive electricity market.

  • PDF

Effects of Muscle Electric Stimulation on Chronic Knee Pain, Activities of Daily Living, and Living Satisfaction for Korean Elderly Women (여성노인의 만성무릎통증, 일상생활활동 및 생활만족도에 미치는 근육 전기자극 요법의 적용 효과)

  • Sok, So-Hyune R.;Kim, Kwuy-Bun
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.3
    • /
    • pp.305-312
    • /
    • 2007
  • Purpose: This study was to examine effects of muscle electric stimulation on chronic knee pain, activities of daily living, and living satisfaction for Korean elderly women. Methods: The design was a nonequivalent control group pretest-posttest study. Subjects were 60 (experimental: 30, control: 30) elderly women 65 years old or above with good orientation and communication. The experimental treatment was electric stimulation on both thigh quadriceps muscles for 15 minutes per time, 3 times per week, for a total of 12 weeks. Measures were the S-F McGill Pain Questionnaire and Arthritis Impact Measurement Scale for chronic knee pain, activities measurement of daily living for activities of daily living, and living satisfaction measurement for living satisfaction. Data was analyzed through the SPSS Win 12.0. Results: Chronic knee pain by S-F MPQ (t=43.563, p=.000) and chronic knee pain by AIMS (t=31.364, p=.000) were significantly decreased in the experimental group, and the activities of daily living (t=124.353, p=.000) and living satisfaction (t=71.268, p=.000) were significantly increased in the experimental group for Korean elderly women. Conclusion: Muscle electrical stimulation decreased chronic knee pain, and increased the activities of daily living and living satisfaction for Korean elderly women. Further studies for muscle electric stimulation need to be done.

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

Measurement System for Vehicle Electric Power using LabVIEW (LabVIEW를 이용한 자동차 발전기 전압 계측시스템)

  • So, Soon-Sun;Yang, Su-Jin;Lee, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5899-5905
    • /
    • 2014
  • Faults in electric power system can be a critical problem for vehicles. The system durability is determined mainly by the durability of their components and operating conditions. Monitoring the conditions of the electric power system may be necessary because it is very difficult to predict precisely when it will fail. Therefore, the aim of this study was to develop a diagnosis system for an electric power system of a vehicle. The alternator voltage, excitation voltage, lamp voltage, battery voltage, and engine rpm from a crank angle sensor are monitored continuously and the system fault can be then detected in real time. NI USB- 9201 DAQ and LabVIEW SW have been used to measure the voltages and analyze the data. Compared to conventional measurements for only each component, an integrated and portable measurement method was developed. In addition to the monitoring the electric power system in real time, the saved data from the measurement also provides valuable information to improve the durability of the components.

A fault prevention diagnostic of power transformer using Frequency Response Analysis (주파수 응답 분석(FRA)을 이용한 전력용 변압기 고장예방 진단)

  • Cho, Yun-Haeng;Lim, Tae-Young;Kim, Jong-Seon;Kim, Gi-Il;Ahn, Kwang-Won;Lim, Seong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.463-464
    • /
    • 2011
  • Currently, different kinds of diagnosis and inspection technologies are applied to prevent the internal mechanical transformation of transformers. For example, examination of internal Partial Discharge of transformer, analysis of transformer oil gas, and measurement Frequency Response Analyzer(FRA) are used to diagnose defect. Especially, diagnosis technique through Frequency Response Analyzer(FRA) has been used and developed from 1960, when it was first introduced, till now to become an important tool to examine presence of defect and to prove quality of machines for the most electric machine producers electric power company in the world. However, diagnosis through FRA is still in introduction level in Korea and the application method for FRA is not established yet. For that reason, study about the application of domestic electric installation according to the FRA is needed. It is expected that the study play an important part in the prevention of defect due to the internal transformation of transformer by introducing measurement theory, providing measurement method, and analyzing application cases.

  • PDF

Electrostatic Charging Measurement and PVC Separation of Triboeletrostatically Charged Plastic Particles using a Fluidized Bed Tribocharger

  • Shin, Jin-Hyouk;Lee, Jae-Keun
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.7-15
    • /
    • 2002
  • A particle flow visualization, electrostatic charging measurement and separation of triboelectrically charged particles in the external electric field by a fluidized bed tribocharger are conducted for the removal of PVC particles from mixed waste plastics. The laboratory-scale triboelectrostatic separation system consists of the fluidized bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PET particles can be imparted negative and positive surface charges respectively due to the difference of triboelectric charging series between particles and particles in the fluidized bed tribocharger, and can be separated by passing them through an external electric field. To visualize these charged particles, He-Ne laser is used with cylindrical lenses to generate a sheet beam. In the charging measurement, the particle motion analysis system (PMAS), capable of determining particle velocity and diameter. is used to non-intrusively measure particle behavior in high strength electric field. The average charge-to-mass ratios of PVC and PET particles are $1.4\;and\;1.2{\mu}C/kg$, respectively. The highly concentrated PVC (91.9%) can be recovered with a yield of about 96.1% from the mixture of PVC and PET materials for a single-stage processing. The triboelectrostatic separation system using the fluidized tribocharger shows the potential to be an effective method for removing PVC from mixed plastics for waste plastic recycling.

  • PDF

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.312-313
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.316-317
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF