• Title/Summary/Keyword: Electric measurement

Search Result 1,648, Processing Time 0.033 seconds

Measurement and Analysis for Electric Fields due to Lightning stepped leaders (뇌방전의 리더진전에 따른 전장파형의 측정과 분석)

  • Lee, B.H.;Jeang, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2164-2166
    • /
    • 1999
  • This paper is describes the measured electric field waveform radiated by lightning discharge. We have performed measurement and analysis of the electric fields associated with stepped leaders. Electric field measurement system was composed of hemisphere electric field sensor, measurement system of a distance from lightning strokes, automatical recording system, A/D board, personal computer etc. A/D board have high sampling time, high speed data processing, 8bit of resolution. Also, measured characteristics of stepped leaders radiated by were analyzed.

  • PDF

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

Meter Optimal Placement in Measurement System with Phasor Measurement Unit (페이저 측정 시스템의 측정기 최적배치)

  • Kim, Jae-Hoon;Cho, Ki-Seon;Kim, Hoi-Cheol;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Calibration of index tables using electric comparators (전기 마이크로미터를 이용한 회전 눈금원판의 교정)

  • Nam, Ki-Chul;Woo, In-Hun;Kim, Jong-Su;Lim, Jae-Sun;Chung, Myung-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.4
    • /
    • pp.36-42
    • /
    • 1987
  • Very accurate calibration is needed to index tables which are necessary for precision angle measurement. The repeatability of index table is less than 0.2 second, so that attentions should be paid to choosing devices to be used in the calibration of index tables. The auto- collimators have been used in the calibration of index tables, but the repeatability of auto- collimators is bad compared with that of index table. In place of autocollimators, we described a method which uses electric comparators which are possessed by most precision measurement laboratories. Electric comparators are set to measure small angle displacement without interrupting the rotation of index tables and the signals of two electric comparators are added to remove the run-out errors of the shafts of index tables. Two index tables have been calibrated simulataneously by this method and the measurement data have been analyzed by the least squares method. We compare the calibration results with those of methods using autocollimator and auto- matic autocollimator and are able to know that the data of electric comparator method lie between the data of autocollimator methods. The repeatability of measurement is less than 0.02 second. The electric comparator method is economical and capable of reducing the uncertainty of the measurement.

  • PDF

Characteristics and Fault Analysis of Electric Devices for High-Speed Railway using Control Signal (제어 신호를 이용한 고속철도 전장품의 특성 및 고장 분석)

  • Han, Young-Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1128-1133
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI (Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the ]measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

Measurement System of a Distance from Lightning Strokes to Observatory and Spectrum Analysis of Electric Fields Radiated from Lightning Discharges (뇌격거리측정계 및 뇌방전에 의해 발생하는 전장의 스펙트럼 분석)

  • Lee, B.H.;Chang, S.H.;Jeang, K.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1656-1658
    • /
    • 1998
  • This paper deals with a measurement system of a distance between lightning strokes and observatory station and spectrum analysis of electric fields radiated from lightning discharges. The distance measurement system, which consists of a loop type magnetic field sensor, a microphone and one chip microprocessor, is connected to a personal computer through RS232 port to acquire and process the data. This system is to use a difference of propagation velocity between an electromagnetic wave and a sonic wave produced by lightning discharge. Also, an electric field waveform and a frequency spectrum were investigated by an electric field measurement system with a hemisphere antenna and a spectrum analyzer with a biconical antenna and a log-periodic antenna, respectively. The results would be used as a basic reference to protect the power systems and electric circuits from lightning overvoltages.

  • PDF

Study on Economical M&V Methoodology for the Lighting Control System (조명제어시스템 경제적인 실적확인 기법 연구)

  • Choi, Kyung-Shik;Han, Seung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

Principles and Comparative Studies of Various Power Measurement Methods for Lithium Secondary Batteries (리튬이차전지 출력측정법의 원리 및 측정법간 비교 연구)

  • Lee, Hye-Won;Lee, Yong-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2012
  • As the market of lithium secondary batteries moves from mobile IT devices to large-format electric vehicles or energy storage systems, the strengthened battery specifications such as long-term reliability longer than 10 years, pack-level safety and tough competitive price have been required. Moreover, even though high power properties should also be achieved for hybrid electric vehicles, it is not easy to measure accurate power values at various conditions. Because it is difficult to choose a proper measurement method and its experimental condition is more complex comparing to capacity measurement. In addition, the power values are very sensitive to power duration time, state-of-charge (SOC) of cells, cut-off voltages, and temperatures, whereas capacity values are not. In this paper, we introduce three kinds of power measurement methods, hybrid pulse power characterization (HPPC) suggested by US FreedomCar, so-called J-pulse by Japan electric vehicle association standards (JEVS) and constant power measurement, respectively. Moreover, with pouch-type unit cells for HEV, experimental power data are discussed in order to compare each power measurement.

Design Models for Electric Coupling Probe in Combline Resonators Using Neural Network (신경망을 이용한 Combline 공진기 내의 전계결합 프로브 설계 모델)

  • 김병욱;김영수
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • Two artificial neural networks (ANN) are used to model the electric coupling probe in the combline resonators. One is used to analyze and synthesize the electric probe, and the other is used to correct errors between the results of the analysis and the synthesis ANNs and the fabrication results. The ANNs for the analysis and the synthesis of the electric probe are trained using the physical dimensions of the electric probe and the corresponding coupling bandwidth which is obtained using the finite element method. The ANNs for the error correction are trained using a very small set of the measurement results. Once trained, the ANN models provide the correct result approaching the accuracy of the measurement. The results from the ANN models show fairly good agreement with those of the measurement and they can be used as good initial design values.

  • PDF