• 제목/요약/키워드: Electric field exposure

검색결과 89건 처리시간 0.026초

Time of Flight Resonace Investigation of Amorphous Selenium Films (비정질 셀레늄 필름의 공명 비행시간 조사)

  • 박지군;박성광;이동길;최장용;안상호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2001
  • We used time-of-flight method to analyse transport properties of charge carrier which is produced by X-ray exposure. It is the research of charge transport and specific property of trap that is performed in direct digital x-ray image receptor. But the results shows us different measurement value of electron and charge drift mobility and it is difficult to precise analysis about charge transport properties and trap mechanism. We measured transit time and drift mobility of charge carriers using time-of-fight method to evaluate the correlation of a-Se thickness change and electric field. We made a testing glass with a-Se of 470 ${\mu}{\textrm}{m}$ thickness on corning glass using thermoevaporation method and built Au electrode with 300nm, 2$\phi$ on both sides of a-Se. As a result of this experiment, electron and hole transit time was each 229.17 $\mu$s and 8.737 $\mu$s at 10V/${\mu}{\textrm}{m}$ electric field and Drift mobility was each 0.00174 $\textrm{cm}^2$/V.s, 0.04584 $\textrm{cm}^2$/V.s.

  • PDF

Influence of Pulsed Electric Field on Accumulation of Calcium in Lactobacillus rhamnosus B 442

  • Goral, Malgorzata;Pankiewicz, Urszula;Sujka, Monika;Kowalski, Radoslaw;Giral, Dariusz;Kozlowicz, Katarzyna
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권1호
    • /
    • pp.44-53
    • /
    • 2020
  • Calcium is an element that performs many important functions in the human body. A study was conducted on the use of a pulsed electric field (PEF) to enrich cells of Lactobacillus rhamnosus B 442 in calcium ions. The highest concentration of calcium ions in bacterial cells (7.30 mg/g d.m.) was obtained at ion concentration of 200 ㎍/ml of medium and with the use of the following PEF parameters: field strength 3.0 kV/cm, exposure time 10 min, pulse width 75 ms and 20 h of culturing after which bacteria were treated with the field. Cell biomass varied in the range from 0.09 g/g d.m. to 0.252 g/g d.m., and the total number of bacteria ranged from 1010 CFU/ml to 1012 CFU/ml. Microscope photographs prove that calcium ions were situated within the cells of the bacteria, and electroporation contributed to an increase in the effectiveness of the ion bioaccumulation process. Samples containing calcium and subjected to electroporation displayed intensive fluorescence. The significance of this research was the possibility of using probiotic bacteria enriched with calcium ions for the production of functional food in subsequent studies.

A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants (원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • 제33권4호
    • /
    • pp.151-160
    • /
    • 2008
  • In Korean nuclear power plants (NPPs), two thermoluminescent dosimeters (TLD) were provided to workers who work in an inhomogeneous radiation field; one on the chest and the other on the head. In this way, the effective dose for radiation workers at NPPs was determined by the high deep dose between two radiation dose from these TLDs. This represented a conservative method of evaluating the degree of exposure to radiation. In this study, to prevent the overestimation of the effective dose, field application experiments were implemented using two-dosimeter algorithms developed by several international institutes for the selection of an optimal algorithm. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, NCRP (55/50), NCRP (70/30), EPRI (NRC), Lakslumanan, and Kim (Texas A&M University) were extensively analyzed as two-dosimeter algorithms. In particular, three additional TLDs were provided to radiation workers who wore them on the head, chest, and back during maintenance periods, and the measured value were analyzed. The results found no significant differences among the calculated effective doses, apart from Lakshmanan's algorithm. Thus, this paper recommends the NCRP(55/50) algorithm as an optimal two-dosimeter algorithm in consideration of the solid technical background of NCRP and the convenience of radiation works. In addition, it was determined that a two-dosimeter is provided to a single task which is expected to produce a dose rate of more than 1 mSv/hr, a difference of dose rates depending on specific parts of the body of more than 30%, and an exposure dose of more than 2 mSv.

Establishment of Cyber Security Countermeasures amenable to the Structure of Power Monitoring & Control Systems (전력계통 제어시스템 구조에 따른 사이버 보안대책 수립)

  • Woo, Pil Sung;Kim, Balho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제67권12호
    • /
    • pp.1577-1586
    • /
    • 2018
  • The emergence of the Smart Grid is an integrated solution for the next generation power system that combines IT technology in the power system to create optimal energy utilization and various services. However, these convergence technologies (power systems and information communications) are not only improving the related technologies but also producing various problems especially exposure to cyber risk. In particular, the intelligent power grid has security vulnerabilities through real-time information sharing among various organically linked systems, and it is more complicated than the cyber risk problem in the existing IT field and is directly connected to national disaster accidents. Therefore, in order to construct and operate a more stable smart grid, this paper analyzes the system of power system control system in Korea, and proposes a cyber security element definition and a countermeasure establishment method of power monitoring & control systems based on security standards of smart grid (No. SPS-SGSF-121-1-1).

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제12권1호
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Development and Performance Evaluation of Aerosol Generator of MWCNTs for Inhalation Toxicology (흡입 독성 평가를 위한 다중벽 탄소나노튜브의 에어로졸 발생장치 개발 및 성능 평가)

  • Lee, Gun-Ho;Jeon, Ki Soo;Yu, Il Je;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • 제9권4호
    • /
    • pp.231-238
    • /
    • 2013
  • Carbon nanotubes (CNTs) are one of the nanomaterials that were discovered by Iijima in 1991 for the first time. CNTs have long cylindrical and axi-symmetric structures. CNTs are made by rolling graphene sheets. Because of their large length-to-diameter ratio, they are called nanotubes. CNTs are categorized as single-walled carbon nanotubes (SWCNTs) or multi-walled carbon nanotubes (MWCNTs) based on the shell structures. CNTs are broadly used in various fields, such as scanning probe microscopy, ultra fine nano balance and medicine, due to their extraordinary thermal conductivity, electrical and mechanical properties. Because long, straight CNTs have the same shape as asbestos, which cause cancer in cells lining the lung, there have been many studies on the effects of MWCNTs on human health that have been conducted. Stable atomization of CNTs is very important for the estimation of inhalation toxicity. In the present study, electro-static assisted axial atomizer (EAAA), which is the instrument that uses MWCNTs and aerosolizes them by transforming the single fiber shape using ultrasonic dispersion and electric field, was invented. EAAA consists of a ultrasonic bath for dispersion of MWCNTs and a particle generator for atomizing single fibers. The performance evaluation was conducted in order to assess the possibilities of 6-hour straight atomization with stability, which is the suggested exposure time in a day for the estimation of inhalation toxicity.

Influences of Plasma Treatment on the Electrical Characteristics of rf-magnefrom sputtered $BaTa_2O_6$ Thin Films (플라즈마 표면 처리가 $BaTa_2O_6$박막의 전기적 특성에 미치는 효과에 관한 연구)

  • Kim, Young-Sik;Lee, Yun-Hi;Ju, Byeong-Kwon;Sung, Mang-Young;Oh, Myung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • 제48권5호
    • /
    • pp.319-325
    • /
    • 1999
  • Direct current(d.c.)leakage current voltage characteristics of radio-frequencymagnetron sputtered BaTa\sub 2\O\sub 6\ film capacitors with aluminum(A1) top and indium tin oxide (ITO) bottom electrodes have been investigatedas a function of applied field and temperature. In order to study surfacetreatment effect on the electrical characteristics of as-deposited film weperformed exposure of oxygen plasma on $BaTa_2O_6$ surface. d. c.current-voltage (I-V), bipolar pulse charge-voltage (Q-V), d. c. current-time (I-t) andcapacitance-frequency (C-f) analysis were performed on films. All ofthe films exhibita low leakage current, a high breakdown field strength (3MV/cm-4.5MV/cm), and high dielectric constant (20-30). From the temperature dependence of leakage current,we can conclude that the dominant conduction mechanism is ascribed toSchottky emission at high electric field (>1MV/cm) and hopping conduction at lowelectric field (<1MV/cm). According to our results, the oxide plasma surfacetreatmenton as-deposited $BaTa_2O_6$ resulted in lowering interfacebarrier height and thus, leakage current when a negative voltage applied to the A1 electrode. This can be explained by reduction of surface contamination via etching surface and filling defects such as oxygen vacancies.

  • PDF

Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication (인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구)

  • Ju, Young-Jun;Gimm, Youn-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제23권2호
    • /
    • pp.251-257
    • /
    • 2012
  • Human body communication means transmitting and receiving data through human body medium or through free space along with the human body skin. Electric field distribution around the human body between the transmitter and the receiver were calculated at five different frequencies with 5 MHz interval between 10 MHz and 30 MHz. Commercial electromagnetic simulation tool was used for the calculation of E-field distributions applying the Korean standard male model including 29 different kinds of human tissues. After calculating specific absorption rate(SAR) values on back of the hand, it was compared with International Commission on Non-Ionizing Radiation Protection(ICNIRP) human protection guideline. While conductivities(${\sigma}$) and relative permittivities(${\varepsilon}_r$) of the human tissues for each frequency were input as the analyzing parameters, electric field intensities near both hands were integrated along the integral line between the nearby electrodes for the calculation of the transmitting and receiving voltages whose ratio was defined as channel loss. The calculated channel losses were about ($75{\pm}1$) dB and showed nearly flat response all through the evaluated frequencies.

The Reliability Evaluation about the Triode-Type CNT Emission Source (삼극형 CNT 전자원에 대한 신뢰성 평가)

  • Kang, J.T.;Kim, D.J.;Jeong, J.W.;Kim, D.I.;Kim, J.S.;Lee, H.R.;Song, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • 제18권2호
    • /
    • pp.79-84
    • /
    • 2009
  • The electron emission source of triode type has been fabricated using CNT paste. The nano Ag particle and photosensitive polymers were added to the CNT paste. The surface roughness of the CNT emitter was uniform by the back exposure method. The added nano Ag particle improves the adhesion and the electric conductance with small variation in the CNTs and between electrode. After the aging with heat-exhausting, the reliability of the triode CNT electron source was secured in the high voltage and current operation for 12 hours. At this time, the gate leakage current was about 10 % less than.