• Title/Summary/Keyword: Electric field calculation

Search Result 192, Processing Time 0.025 seconds

AC Loss Calculation in High Temperature Superconductors Using Slab model (Slab모델을 이용한 HTS AC 손실의 계산)

  • 최세용;주진호;류경우;나완수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.102-103
    • /
    • 2001
  • In this paper we calculate the AC Loss in the superconducting slab carrying ac transport current. Magnetic diffusion equation for computation of the electric field and current distribution are based on Maxwell's equations and non-linear constitutive equation. The E-J characteristics of superconductor are applied to computation. We will present the result of the high-temperature superconductor case comparison with the slab of low temperature superconductor.

  • PDF

Estimation of Bubble Behavior and PD Initiation Voltage in the Simulated Electrode System of High Temperature Superconducting Coil (고온초전도코일 모의전극계에서 기포거동 및 부분방전개시전압의 추정)

  • 석복렬;최명준;김용한;김진수;김종구
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2001
  • This paper deals with the numerical estimation of the bubble behavior and the partial discharge (PD) initiation voltage on the basis of electric field calculation with the coaxial coil layer-to-cylindrical electrode system for the simulation of high temperature superconducting coils. The theoretical results of bubble behavior and the PD initiation voltages show fairly good agreement with the experimental results.

  • PDF

Calculation of Radiation Patterns on Phased Arry Antenna of Slant Grid (경사진 배열 구조를 갖는 위상배열 안테나의 복사패턴 계산)

  • 하헌태;김세윤
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.1
    • /
    • pp.1-7
    • /
    • 1993
  • The radiation characteristics of a phased array antenna consisted of rectangular waveguides with a slant grid are investigated here. In particular, the effects of the slant angle on the radiation patterns are calculated by solving numerically the integral equation to the electric field over the waveguide aperture in view of the modal analysis. And it is found that the blindness on the radiation pattern can be moved by inserting a dielectric plug or sheath properly.

  • PDF

Study on an EHD air mover (Electro-hydrodynamic air mover에 관한 연구)

  • 이정오;양배덕
    • 전기의세계
    • /
    • v.22 no.3
    • /
    • pp.63-71
    • /
    • 1973
  • When ions move in the air under an electric field, momentum is transferred from ions to neighboring particles. The wind is raised therefore, if the ion-flow is dominant in one direction. Using this mechanism, authors developed a fan which has no moving parts, and named it EHD AIR MOVER. This paper describes its theory with experimental results. Air velocity of 450ft/min is obtained by the ion current of 5*10$\^$-6/A/cm$\^$2/. Comparison of the theoretical calculation with the experimental data shows satisfactory agreement.

  • PDF

3-Dimensional Analysis of Permanent Magnet Stepping Motor With Claw Poles (전자정보기기 구동용 영구자석형 스테핑 모터의 3차원 해석)

  • An, Ji-Hyun;Park, Seung-Chan;Rhyu, Se-Hyun;Jung, In-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.107-109
    • /
    • 2004
  • Stepping motors are widely used for various electric instruments. In case of analysing claw pole PM slopping motor 3-dimensional analysis is necessary for accurate field calculation. This paper presents static torque characteristics of a permanent magnet type stepping motor with claw poles using three-dimensional finite element analysis.

  • PDF

Numerical Investigation of Pressure Fluctuation Reducing in Draft Tube of Francis Turbines

  • Li, WF;Feng, JJ;Wu, H;Lu, JL;Liao, WL;Luo, XQ
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.202-208
    • /
    • 2015
  • For a prototype turbine operating under part load conditions, the turbine output is fluctuating strongly, leading to the power station incapable of connecting to the grid. The field test of the prototype turbine shows that the main reason is the resonance between the draft tube vortex frequency and the generator natural vibration frequency. In order to reduce the fluctuation of power output, different measures including the air admission, water admission and adding flow deflectors in the draft tube are put forward. CFD method is adopted to simulate the three-dimensional unsteady flow in the Francis turbine, to calculate pressure fluctuations in draft tube under three schemes and to compare with the field test result of the prototype turbine. Calculation results show that all the three measures can reduce the pressure pulsation amplitude in the draft tube. The method of water supply and adding flow deflector both can effectively change the frequency and avoid resonance, thus solving the output fluctuation problem. However, the method of air admission could not change the pressure fluctuation frequency.

Derivation of the Transient. Solution of the Horizontal Interfacial Electric Field Generated by a Tiny Horizontal Current Source on a Uniaxially Anisotropic Half-Space Dielectric (단축 이방성 반공간 유전체 표면에서 수평 미세 전류원에 의해 발생하는 수평 경계면 전기장에 대한 시영역 해의 유도)

  • 이원석;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.313-321
    • /
    • 2000
  • This paper deals with a kind of the half-space interfacial problem in time domain, requiring the calculation of the horizontal electric field generated by a tiny impulsive current source located horizontally at the interface between an isotropic upper half-space and a uniaxially anisotropic lower half-space. With the Cagniard-de-Hoop method adapted for our interfacial case, we obtain the explicit-form solution for this electric field. We also investigate the impulse radiation in the radial direction. The impulse components of Dirac $\delta$-function type in transient waveforms are important for the understanding of the interfacial far-field characteristics. The uniaxial case is a generalization of the isotropic one, and the explicit solutions of the uniaxial problem in this paper reduce to the solutions of the isotropic problem if the anisotropy is removed.

  • PDF

A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition (연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

Pressure-Rise Measurement and Analysis of Low Current Interruption Capability of a 72.5kV 20kA Gas Circuit Breaker for Electrical Railway System (72.5kV 20kA 전철용 가스차단기의 압력상승 측정 및 소전류 차단성능해석)

  • Song, K.D.;Park, K.Y.;Chong, J.K.;Oh, Y.H.;Min, K.S.;Park, Ki-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.164-166
    • /
    • 1998
  • This paper presents the results of the measured pressure-rise and the analyzed results of the cold gas flow-field in a 72.5kV 20kA gas circuit breaker for the electrical railway system. The analysis of cold gas flow field and the calculation of electric field strength have been performed in 3 types of interrupters and the low current interruption capability has been estimated for each of the gas circuit breaker considering the opening speed, the nozzle shape and the stroke length.