• Title/Summary/Keyword: Electric fan

Search Result 180, Processing Time 0.023 seconds

Vibration Analysis of Small Universial Motor by Regression Analysis (회귀분석을 이용한 소형 유니버셜 모터의 진동해석)

  • Cha, W.J.;Choi, Y.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.86-91
    • /
    • 2002
  • The regression analysis in the six sigma process is used to reduce the vibration of an electric grinder. The vibration characteristics and the contribution of each part to overall vibration of the electric grinder is investigated through various vibration measurements and frequency analysis for the assembled and disassembled one. Then the application of the regression analysis finds out that the rotating components of the armature have more severe contributions to the overall vibration than the frequency components of the fan or the gear part, which is decided with higher value of the coefficient of determination. The unbalance and looseness of the armature and the fan are tested again by the regression analysis in order to decide how much unbalance or looseness should be reduced for the predetermined goal of vibration level of the electric grinder. These results show that the regression analysis can be a valuable tool in production line to decide where and how much faults needs to be adjusted for the reduction of vibration and noise.

  • PDF

Internal Flow Condition of High Power Contra-Rotating Small-Sized Axial Fan

  • Shigemitsu, Toru;Fukutomi, Junichiro;Agawa, Takuya
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 2013
  • Data centers have been built with spread of cloud computing. Further, electric power consumption of it is growing rapidly. High power cooling small-sized fans; high pressure and large flow rate small-sized fan, are used for servers in the data centers and there is a strong demand to increase power of it because of increase of quantity of heat from the servers. Contra-rotating rotors have been adopted for some of high power cooling fans to meet the demand for high power. There is a limitation of space for servers and geometrical restriction for cooling fans because spokes to support fan motors, electrical power cables and so on should be installed in the cooling fans. It is important to clarify complicated internal flow condition and influence of a geometric shape of the cooling fans on performance to achieve high performance of the cooling fans. In the present paper, the performance and the flow condition of the high power contra-rotating small-sized axial fan with a 40mm square casing are shown by experimental and numerical results. Furthermore, influence of the geometrical shape of the small-sized cooling fan on the internal flow condition is clarified and design guideline to improve the performance is discussed.

Design optimization of the staking line for an electric fan blade using CFD (CFD를 이용한 선풍기 날개의 스태킹 라인 최적 설계)

  • Park, Seunghwan;Ryu, Minhyoung;Cho, Leesang;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.903-910
    • /
    • 2014
  • Electric fans, which consist of axial blades, are operated by the induction motor. In this paper, the objective of this study is the performance improvement of the base model fan using the design optimization. In order to aerodynamic analysis, computational simulations are performed using commercial tool ANSYS-CFX ver. 14.5. And k-${\omega}$ SST turbulence model is used for the CFD analysis. The design variables are set up as sweep and lean angles. Volumetric flow rate and torque of the fan blades are fixed to objective function. The optimized model is shown the increment of the volumetric flow rate and the reduction of the torque compared with the base model. The experimental procedure is followed KS C 9301. CFD results and experimental results are fairly well matched.

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.

Analysis of Thermal Characteristic for VCTFK, VFF, HIV and CV Wring by Electric Fan at Livestock Barn (축산용 송풍기 부하에 대한 VCTFK, VFF, HIV 및 CV 전선의 열적특성 분석)

  • Kim, Doo-Hyun;Yoo, Sang-Ok;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.35-39
    • /
    • 2014
  • This paper is purposed to analyze the thermal characteristics of wiring according to the number of electric fans in operation for 10 fans over 10 year old and 10 fans less than 1 year old in livestock barn. In order to achieve the goal in the paper, it selected VCTFK, VFF, HIV, and CV wiring that were used most at 64 livestock barns in Cheongwon location through the research on the field investigation. Finally, it also analyzed the dangers by deducing the thermal characteristic data of 4 wiring. In addition, this paper suggested the mode of load current (the most frequently measured load current) of both over 10 years old and less than 1 year old electric fans. The data of this paper could be used for the maintenance and management of wiring and fire investigation of livestock barn as well as for materials of safe designs of wiring of electric fans.

Implementation of Automation System for the Fluid Analysis of Axial Fan Using Supercomputer (슈퍼컴퓨터 활용 축류팬 유동해석 자동화 시스템 개발)

  • Kim, Myung-Il;Lee, Seung-Min;Lee, Sang-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.288-291
    • /
    • 2008
  • Recently, the importance and necessity of engineering analysis has shown a steady growth. However, researchers working in small and medium enterprises know little about the usefulness of engineering analysis and suffer from lack of technical knowledge. Axial fan is air fluid machinery in various fields of industry such as automobile, electric appliance, and heavy machinery. It is also a time and budget consuming equipment to develop the axial fan through physical experiments. In order to overcome this problem, we have designed and developed a web-base automated simulator for axial fan's fluid analysis using supercomputer. Automated simulator means that all of processes for engineering analysis including pre-process, solving, and post-process can be performed automatically without user intervention after transferring fan model(CAD files) made by user. After executing the simulator with some parameters, user can receive the report including pressure P and flow rate Q. In this paper, we introduce the architecture of our easy and efficient automated engineering analysis simulator, related techniques and result of development.

  • PDF

Study on the Noise Reduction of BLDC Fan Motor by Cogging Torque Reduction (코깅토크 저감에 의한 BLDC Fan & Motor의 공진 소음 개선에 관한 연구)

  • Shin, Hyoun-Jeong;Lee, En-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1217-1222
    • /
    • 2013
  • It is very important to diminish noise source of electric motor systems that are used for home appliance area. We have studied on the noise reduction of BLDC motor, mainly focusing on reducing noise source from cogging torque. This noise source causes resonance of fan & motor systems. This study showed that the higher harmonic component of the cogging torque was the main factor for noise generation. Therefor, to reduce noise of bldc motor for refrigerator, this study suggested peanut shaped magnet which surface flux has similar sinusoidal wave form.

The study on the Characteristics and Design of the Thermo Motor (Thermo Motor 설계 및 특성연구)

  • Koo, Dae-Hyun;Kim, Jin-Bong;No, Kyu-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1035-1037
    • /
    • 1993
  • Thermo motor that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil, it is simpler and cheaper than general fan heater. In this study, shaded-pole motor was used that is low cost and simple in spite of low efficiency.

  • PDF

An Investigation of Combustion Emission Characteristics of Kerosene Fan Heater with Addition of Water Droplets by Ultrasonic Atomizer (초음파 수첨가 연소에 의한 석유 홴 히터의 배기가스 특성 고찰)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.44-53
    • /
    • 1999
  • This study is concerned with the emission characteristics of kerosene fan heater, which is burned with kerosene and water droplets simultaneously in the burner, in order to prohibit the emissions of harmful exhaust gas and reduce smell caused by incomplete combustion, and the addition of water droplets to the conventional kerosene fan heater was performed by ultrasonic atomizer. For the investigation of this study, the measurement of exhaust gas components and exhaust gas temperature was carried out by using an automatic combustion gas analyser and $NO_x$ analyser, and the measurement of consumption weight of oil and water was obtained by using electric digital balance. Consequently, according as the water percent weight ratio of about $21{\sim}23%$ was supplied for this study, it was found that the combustion-generated $NO_x$ and CO emissions were reduced very largely, but the emissions of $O_2\;and\;CO_2$ and the temperature of exhaust gas were not changed.

  • PDF

A Study on Low Noise Cooling/Ventilation System for Large Electric Motor (대형 전동기 냉각/통풍 시스템의 저소음화 연구)

  • Jo, Hye-Young;Jang, Ji-Sung;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.973-974
    • /
    • 2014
  • 대형 전동기의 주요 소음원은 전자기 소음과 냉각/통풍 시스템 소음이며, 이 중 냉각/통풍 시스템이 전체 소음에 큰 영향을 미친다. 본 논문에서는 대형 전동기의 저소음 냉각/통풍 시스템 개발을 위해 저소음 냉각 팬을 개발하고 팬 커버 내부의 유로를 개선하였다. 유동해석은 상용 CFD 소프트웨어를 이용하였으며 팬 커버 내의 scroll 형상 및 air guide, baffle 의 유무에 따라 팬 커버의 압력손실을 계산하였다. 해석을 통해 팬 커버 내부의 난류 유동과 압력손실이 가장 작은 팬 커버 형상을 도출하였으며 개선된 냉각/통풍 시스템이 기존 냉각/통풍 시스템보다 6.5dB 감소된 것을 확인하였다.

  • PDF