• Title/Summary/Keyword: Electric fan

Search Result 180, Processing Time 0.027 seconds

Design and fabrication of a high power LED searchlight (고출력 LED 탐조등의 설계 및 제작)

  • Kim, Se-Jin;Kim, Sun-Jae;Ha, Hee-Ju;Kil, Gyung-Suk;Kim, Il-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.737-743
    • /
    • 2014
  • This paper dealt with a retrofit high power LED searchlight to replace conventional 1kW halogen searchlights. The design specification meets KDS 6230-1046-1 and KS V 8469. An optical lens with the beam angle of $6^{\circ}$ was used to meet the luminous intensity of 800,000cd at $0^{\circ}$ in horizontal line. Heat dissipation of the LED searchlight adopted a free air cooling type which does not use a fan or a heat-pipe. From the test results, power consumption of the prototype LED searchlight was 148W which was saved by 85% comparing a halogen searchlight of 1kW. Luminous intensity was 945,000cd at $0^{\circ}$ in horizontal line, satisfying KS V 8469. Luminous efficacy was improved by 4.7 times higher than that of the halogen searchlights. Beam angle, color temperature, and color rendering index(CRI) was $5.4^{\circ}$, 5,500K, and 70, respectively. Surface temperature of the LED searchlight was below $60^{\circ}C$ and surrounding temperature of the SMPS installed inside was below $50^{\circ}C$ which were satisfied with the IEC 60092-306.

Determination of Hot Air Drying Characteristics of Squash (Cucurbita spp.) Slices

  • Hong, Soon-jung;Lee, Dong Young;Park, Jeong Gil;Mo, Changyeun;Lee, Seung Hyun
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2017
  • Purpose: This study was conducted to investigate the hot air drying characteristics of squash slices depending on the drying conditions (input air velocity, input air temperature, and sample thickness). Methods: The developed drying system was equipped with a controllable air blower and electric finned heater, drying chamber, and ventilation fan. Squash (summer squash called Korean zucchini) samples were cut into slices of two different thicknesses (5 and 10 mm). These were then dried at two different input air temperatures (60 and $70^{\circ}C$) and air velocities (5 and 7 m/s). Six well-known drying models were tested to describe the experimental drying data. A non-linear regression analysis was applied to determine model constants and statistical indices such as the coefficient of determination ($R^2$), reduced chi-square (${\chi}^2$), and root mean square error (RMSE). In addition, the effective moisture diffusivity ($D_{eff}$) was estimated based on the curve of ln(MR) versus drying time. Results: The results clearly showed that drying time decreased with an increase in input air temperature. Slice thickness also affected the drying time. Air velocity had a greater influence on drying time at $70^{\circ}C$ than at $60^{\circ}C$ for both thicknesses. All drying models accurately described the drying curve of squash slices regardless of slice thickness and drying conditions; the Modified Henderson and Pabis model had the best performance with the highest R2 and the lowest RMSE values. The effective moisture diffusivity ($D_{eff}$) changes, obtained from Fick's diffusion method, were between $1.67{\times}10^{-10}$ and $7.01{\times}10^{-10}m^2/s$. The moisture diffusivity was increased with an increase in input air temperature, velocity, and thickness. Conclusions: The drying time of squash slices varied depending on input temperature, velocity, and thickness of slices. The further study is necessary to figure out optimal drying condition for squash slices with retaining its original quality.

Exploring the Accuracy and Methods of Estimation on Base Physical Quantities (기본물리량 어림의 정확성 및 방법에 대한 탐색)

  • Song, Jin-Woong;Kim, Hae-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.21 no.1
    • /
    • pp.76-88
    • /
    • 2001
  • This study explored people's accuracy and methods of estimating some base physical quantities, i.e. length, mass, time and temperature. A total of 40 members, ranging from freshmen to professors, of a physics education department of a local university were asked to make two different kinds of estimations, intuitive and operational, on two sets of objects. For intuitive estimation, they were asked to make estimations on four given objects (length - wood chopsticks, mass - rubber eraser, time electric fan, temperature - water in a cup) as soon as they faced with the objects, usually within a few seconds of seeing. For operational estimation, they were allowed to make estimations on a different set of objects (length - plastic rod, mass - lock, time - simple pendulum, temperature - water in a cup) with enough time and they could apply various available methods (e.g. using pencil to estimate the object's length, counting their own pulse rate to estimate time) for the estimation. The findings of this study can be summarized as follows: (1) for length, mass and temperature the intuitive estimations were better performed while for the time estimation the result was the reverse; (2) there was no positive relationship between the amount of physics experience and the accuracy of the estimation; (3) in general, people's accuracy of the length estimation was best performed while their mass estimation was worst performed; (4) people used their own various methods for estimation, esp. using nearby objects around them and applying mental units which have convenient values (e.g. 30cm, 50cm, 1kg, 1 Keun, 1 second).

  • PDF

Numerical Study on Surface Air-Oil Heat Exchanger for Aero Gas-Turbine Engine Using One-Dimensional Flow and Thermal Network Model (항공기 가스터빈용 오일쿨러 해석을 위한 1 차원 열유동 네트워크 수치적 모델 개발 및 연구)

  • Kim, Young Jin;Kim, Minsung;Ha, Man Yeong;Min, June Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.915-924
    • /
    • 2014
  • In an aero gas-turbine engine, a surface air-oil heat exchanger (SAOHE) is used to cool the oil system for the gearboxes and electric generators. The SAOHE is installed inside the fan casing of the engine in order to dissipate the heat from the oil system into the bypass duct stream. The purpose of this study was to develop an effective numerical method for designing an SAOHE for an aero gas-turbine engine. A two-dimensional model using a porous medium was developed to evaluate the aero-thermal performance of the fins of the heat exchanger, and a one-dimensional flow and thermal network program was developed to save time and cost in the evaluation of the heat exchanger performance. Using this network program, the pressure drop and heat transfer performance of the heat exchanger were predicted, and the results were compared with two-dimensional computational fluid dynamics results and experiment data for validation.

Triboelectrostatic Separation of Unburned Carbon from Flyash for Ash Recycling (마찰대전 정전분리기를 이용하여 석탄회에 함유된 미연탄소분 제거에 관한 연구)

  • 이재근;김성찬;손낙원;김두현;오정근
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.15-21
    • /
    • 1997
  • Flyash from a coal-hed power plan1 is produced approximtcly 3 million tons m 1996 and causes the serious environmentalpmblem due to the disposal in the ash pond. Flyash is an accepted additive in concrete where it adds strength, sulfate ateresistanceand reduced cost, provided acccptablc levcls of unbunrned carbon are mmtmed This papzr describes to investigate thc technicalfeasibility of a dry triboelcctrostatlcp roccss to scparate unburned carbon h m f lyash into economically valuable produck Puliclesof unburned carbon and flyash can be impded positivc and negative surface charzes. rcapeclively. with a copper tniochargcr dueto dirferences in the work function values of thc particles and the tnbacharger. and cm he separated by passing thcm throuph anexternal electic field. A laboratory s d e separation system consists of r sacw feeder for ash supply, a tniocharger, verticalcollecling copper plates, power supplies, a flow meter, and a fan. Separation tests taking into account separahian efficiency and ashrecovery showed that flyash recovery was sh-nngly dependent an thc tnbocharger geomzhy, elect"c ficld strength. flyssh s ~ c a,n dash feeding late. Optimal separation conditions were flyash size less than 125 Fm and electric field shcngrh of 200 kV1m. Ovcr 80%of the flyash with 7% lass on ignition was recovered at wrbon contznts less than 3%bon contznts less than 3%

  • PDF

Design of Pattern Classifier for Electrical and Electronic Waste Plastic Devices Using LIBS Spectrometer (LIBS 분광기를 이용한 폐소형가전 플라스틱 패턴 분류기의 설계)

  • Park, Sang-Beom;Bae, Jong-Soo;Oh, Sung-Kwun;Kim, Hyun-Ki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.6
    • /
    • pp.477-484
    • /
    • 2016
  • Small industrial appliances such as fan, audio, electric rice cooker mostly consist of ABS, PP, PS materials. In colored plastics, it is possible to classify by near infrared(NIR) spectroscopy, while in black plastics, it is very difficult to classify black plastic because of the characteristic of black material that absorbs the light. So the RBFNNs pattern classifier is introduced for sorting electrical and electronic waste plastics through LIBS(Laser Induced Breakdown Spectroscopy) spectrometer. At the preprocessing part, PCA(Principle Component Analysis), as a kind of dimension reduction algorithms, is used to improve processing speed as well as to extract the effective data characteristics. In the condition part, FCM(Fuzzy C-Means) clustering is exploited. In the conclusion part, the coefficients of linear function of being polynomial type are used as connection weights. PSO and 5-fold cross validation are used to improve the reliability of performance as well as to enhance classification rate. The performance of the proposed classifier is described based on both optimization and no optimization.

Analysis of Cable Protection of Duct in Lightning and HIRF Environment of UAM Aircraft and a Proposal for Certification Guidance (UAM 항공기 낙뢰 및 HIRF 환경에서 덕트의 케이블 보호 성능 분석 및 인증기술에 관한 연구)

  • Kim, Dong-Hyeon;Jo, Jae-Hyeon;Kim, Yun-Gon;Lee, Hakjin;Myong, Rho-Shin
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.23-34
    • /
    • 2022
  • Cities around the world are increasing their demand for Urban Air Mobility (UAM) aircraft due to traffic congestion with population concentration. Aircraft with various shapes depending on fixed-wing and propulsion systems, are being prepared for commercialization. Airworthiness certification is required as it is a manned transportation vehicle that flies in the city center and transports people on board. UAM aircraft are vulnerable to lightning and HIRF environments due to the increasing use of composite materials, the use of electric motors, and use of electronic equipment. Currently, the development of certification technology, guidelines, and requirements in lightning and HIRF environments for UAM aircraft is incomplete. In this study, the certification procedures for lightning and HIRF indirect impacts of rotorcraft shown in AC 20-136B and AC 20-158A issued by the Federal Aviation Administration (FAA), were verified and applied to the computerized simulation of UAM aircraft. The impact of lightning and HIRF on ducted fan UAM aircraft was analyzed through computerized simulation, and the basis for establishing practical guidelines for certification of UAM aircraft to be operated in the future is presented.

Field Survey on Smart Greenhouse (스마트 온실의 현장조사 분석)

  • Lee, Jong Goo;Jeong, Young Kyun;Yun, Sung Wook;Choi, Man Kwon;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.27 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • This study set out to conduct a field survey with smart greenhouse-based farms in seven types to figure out the actual state of smart greenhouses distributed across the nation before selecting a system to implement an optimal greenhouse environment and doing a research on higher productivity based on data related to crop growth, development, and environment. The findings show that the farms were close to an intelligent or advanced smart farm, given the main purposes of leading cases across the smart farm types found in the field. As for the age of farmers, those who were in their forties and sixties accounted for the biggest percentage, but those who were in their fifties or younger ran 21 farms that accounted for approximately 70.0%. The biggest number of farmers had a cultivation career of ten years or less. As for the greenhouse type, the 1-2W type accounted for 50.0%, and the multispan type accounted for 80.0% at 24 farms. As for crops they cultivated, only three farms cultivated flowers with the remaining farms growing only fruit vegetables, of which the tomato and paprika accounted for approximately 63.6%. As for control systems, approximately 77.4% (24 farms) used a domestic control system. As for the control method of a control system, three farms regulated temperature and humidity only with a control panel with the remaining farms adopting a digital control method to combine a panel with a computer. There were total nine environmental factors to measure and control including temperature. While all the surveyed farms measured temperature, the number of farms installing a ventilation or air flow fan or measuring the concentration of carbon dioxide was relatively small. As for a heating system, 46.7% of the farms used an electric boiler. In addition, hot water boilers, heat pumps, and lamp oil boilers were used. As for investment into a control system, there was a difference in the investment scale among the farms from 10 million won to 100 million won. As for difficulties with greenhouse management, the farmers complained about difficulties with using a smart phone and digital control system due to their old age and the utter absence of education and materials about smart greenhouse management. Those difficulties were followed by high fees paid to a consultant and system malfunction in the order.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.