• Title/Summary/Keyword: Electric apparatus

Search Result 321, Processing Time 0.03 seconds

Development of Stacking and Transfer System for the Agile Fabrication (쾌속제작을 위한 적층 및 이송장치 개발)

  • 엄태준;주영철;민상현
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.126-130
    • /
    • 2002
  • This paper presents the basic concept of new solid freeform fabrication system using rapid prototyping method. The system could fabricate an arbitrary ceramic form by laser cutting, transferring, stacking, and sintering of each slide. The system consists mainly of laser apparatus. X-Y table, a slide transferring system, and electric oven. The system could fabricate an object that has smooth surface with comparatively short period of time. The system is effective in terms of its direct fabrication capability without second mechanical process. The fabricated shape could directly be used as part of a whole assembly and therefore its method could be applied to various application areas.

  • PDF

Fluid Analysis for Verifying Interrupting Capability of UHV GCB (초고압 GCB의 차단성능 검증을 위한 유동해석)

  • Kim, D.S.;Seo, K.B.;Song, W.P.;Chung, Y.H.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.19-21
    • /
    • 2002
  • Recently, it has become more competitive to take larger market share among domestic companies manufacturing high-power apparatus. Unfortunately, the size of total market in this field is being smaller than before because the business of transmission and distribution of electric power is being shifted from government control to private management. To save this situation, we are trying to develop new high-voltage Gas Insulated Switchgear for export such as 245kV GIS and 300kV GIS. It is very important to make GIS compact size to have international competitiveness against European companies. By reducing GIS's dimensions same as 170kV class, we expect to launch abroad successfully. Many factors should be considered to achieve good performance during short-circuit making-breaking. Analysis on cold gas flow is one method widely used to evaluate small-current interruption. Through this analysis, we can examine the dielectric characteristics at the weak points in the circuit-breaker. In this paper, we describe the results of cold-gas flow analyses on 245kV and 300kV circuit-breakers.

  • PDF

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

Potential Ruse as a function of the Buried Depth for Structure (구조체의 매설깊이에 따른 전위상승)

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.27-28
    • /
    • 2006
  • This paper deals with an approach to the reduction of potential rise according to the buried depth of structure. In order to analyze the surface potential rise of structure, an electrolytic tank which simulates the semi-infinite earth has been used. The potential rise has been measured and analyzed for types of structure using an electrolytic tank experimental apparatus in real time. The structure models were designed through reducing real buildings and fabricated with two types on a scale of one-one hundred sixty When a test current flowed through structure models, the potential rise of outline frame type(structure model A) was more high than that of electric cage type(structure model B). The distributions of surface potential rise are dependent on the buried depth of structure model.

  • PDF

A Study on the Explosion Riskiness with Flying of Activated Carbon (활성탄의 부유중 폭발 위험성에 관한 연구)

  • 김정환;현성호;이창우;함영민
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.3-9
    • /
    • 1998
  • We investigated the weight loss according to temperature using TGA in order to find the thermal hazard of brand-new activated-carbon and disused activated-carbon dusts, and the properties of dust explosion in variation of the specific surface area of their dust with the same particle size. Using hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of activated carbon dust. The explosion pressure of both activated carbon increased as the specipic surface area increased. The results indicated that brand-new activated-carbon of which specific surface area was larger three to four times than that of disused activated-carbon was much easier of dust explosion.

  • PDF

A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession (화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구)

  • Jung, Byeong-Sun;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

A Study on the Causal Relationship Between Electricity Consumption and Output in Manufacturing Sectors of Korea (국내 제조업종별 전력소비와 경제산출간 인과관계 분석)

  • Park, Min Hyuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.65-72
    • /
    • 2017
  • This study analyzed causal relationship between electricity consumption and economic output (GDP) for Korea from 2001 to 2014 employing the vector error-correction model estimation by manufacturing sector. The results of unit-roots tests show that all sectoral GDP and electricity consumptions were not stationary. And cointegration tests show that processed foods, Wood Pulp Paper, electricity apparatus, Precision Medical sectors had a linear combinations in the long run between electricity consumptions and economic growth. With respect to the direction of causality, manufacturing sector has a uni-directional running from economic output (GDP) to electricity consumption in short term. The results of study show that sectoral causal relation were different each other in short term and long term. These findings imply that electricity demand management policy focusing on efficiency improvement is necessary to minimize negative impacts on economic growth and to adopt suitable structural policies can induce energy conservation.

Performance and Availability of Seawater Distiller with Heat Pipe Utilizing Low-Grade Waste Heat (저급 폐열 이용 히트파이프 해수담수기의 성능과 유용성)

  • Park, Chang-Dae;Chung, Kyung-Yul;Tanaka, Hiroshi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.81-86
    • /
    • 2013
  • Exhaust gas from a small portable electric generator is simply exhausted to the surroundings because the capacity and quality of the waste heat of this gas is generally not sufficient to recover and utilize. We have proposed a seawater distiller utilizing the thermal energy of waste gas from an electric generator. The distiller recovers heat from the waste gas by means of a heat pipe and uses it effectively through a multiple-effect diffusion-type structure. We constructed an experimental apparatus with a vertical single-effect still having a 4-stroke 50 cc generator engine and found that the experimental results for distillate productivity show good agreement with the theoretical predictions. The results show that the distiller can recover 52 W of waste heat from the gas at $171^{\circ}C$, and ~85% of the recovered heat can be utilized for distillation to produce 70 g/h of fresh water. This is equivalent to a productivity of 500 g/h in the case of a 10-effect still. Therefore, the proposed distiller should be useful in remote areas where electricity and water grids are inadequate.

The Study of the Characteristic of Ti Thin Film Using Small Magnetron Sputtering Method for Sunglass Lens (소형 Magnetron sputtering 방법에 의한 썬글라스 렌즈용 Ti 박막의 특성연구)

  • Park, Moonchan;Jung, Boo Young;Lee, Jong Geun;Joo, Kyung Bok;Lee, Wha Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Purpose: Ti thin films were deposited on slide glass and CR-39 lenses using small magnetron sputtering apparatus to of Ti thin films. Methods: The thickness of Ti thin films were measured by cross section SEM, the transmittance and reflectance of them were obtained using spectrophotometer, the refractive index and extinction of them were obtained from VASE data. Results: The transmittances of Ti thin films with 60 nm, 120 nm, 140 nm thickness were a little change within the visual region from 400 nm to 750 nm, but were increased a little amount at near 400 nm. The transmittance of 60 nm, 120 nm, 140 nm Ti thickness in d-line was 30%, 25%, 20%, respectively. Also, it was shown that the refractive indices and extinction coefficients of the Ti thin films obtained from VASE were similar to those of Ti thin film offered macleod program. Conclusions: Ti films on CR-39 with these transmittances were available for sunglass lens. It was indicated that the refractive indices and extinction coefficients of the Ti thin films were decreased with the thickness of Ti thin film, for the thickness of Ti thin films was due to very thin.

  • PDF

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.