• Title/Summary/Keyword: Electric Power Lines

Search Result 485, Processing Time 0.026 seconds

Propagation Characteristics of Potential Tsunamis in Okinawa Trough (오키나와 트러프 잠재 지진해일 전파특성)

  • Kim, Jong-Hak;Choi, Weon-Hack;Bae, Jae-Seok;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.3
    • /
    • pp.268-276
    • /
    • 2008
  • Potential tsunamis generated in Okinawa Trough were simulated for the investigation of the propagation characteristics in the southwestern sea of Korean Peninsula. Shallow waters in the continental shelf of East China Sea and deep waters in Okinawa Trough play an important role in the propagation characteristics of the tsunamis generated in this region. The propagation characteristics can be classified into two phases according to the stage of propagation. In the first phase, the tsunamis propagate both northeast and southwest along the deep water of the trough. In the second phase, the tsunamis enter the continental shelf of the East China Sea at right angles to topographic contour lines. Simulated results show that the tsunamis generated in the Okinawa Trough give a weak influence to the southern and western coasts of Korea due to the special topography of the southwestern sea of Korean Peninsula.

A Study on the Radiation Characteristics of Microstrip Array Antennas on the Nonplanar Surface (곡면에서의 마이크로스트립 어레이 안테나의 복사 특성에 관한 연구)

  • 구연건;이정수;고광태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.2
    • /
    • pp.121-136
    • /
    • 1989
  • In this paper, an attempt has been made to analyze the theoretically and verify experimentally the effect of curvature on the radiation characteristics of microstrip array antennas mounted conformally on the concave surface and the convex surface of the cylindrical body. The analysis of single element microstrip antenna is made by using the analysis method of Transmission Line Model. The theory of array antennas is established by application of the method of transformed coordinates, in which the translation and the ratation about each single element arrayed two-demensionally on the nonplanar surface are under consideration, and it is investigated by computation of the synthetic electric field strength in the far zone. In addition, various radiation characteristics, such as return loss, resonant frequency, radiation pattern, half-power, beamwidth, gain, are measrued and compared with the theroetical values according to the variation of curvature, by designing and building 4-element array microstrip antenna operating at 10 GHz, and microstrip feed lines. As predicted in theroy, it is verified that radiation pattern of antennas mounted on the concave and the convex surfaces alike broadens as the radius of curvature decreases. And for the curved surfaces, aggrement between computed values of the total synthetic radiation power pattern by the method of transformed coordinates and measured valuse is good. Besides, it is found that resonant frequency, input impedance and gain are hardly affected by the radius of curvature.

  • PDF

Dynamic Characteristics of Pressure Propagation According to Boundary Condition Changes in a Transmission Line (경계조건변화에 따른 동력전달관로의 동특성)

  • 나기대;유영태;김지환
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.75-82
    • /
    • 2002
  • Design for a quiet operation of fluid power system requires the understanding of noise and vibration characteristics of the system. It's not easy to analyze noise problem in hydraulic cylinder used in typical actuator Because they've got complex fluid dynamics. One of the fundamental problems associated with the hydraulic system is the pulsating flow in pipe lines, which can be tackled by the analysis under simplifying assumptions. The present study focuses on theoretic analysis and experimental study on the dynamics of laminar pulsating flow in a circular pipe. We analyze the propagation characteristics of the pressure pulse within a hydraulic pipe line taking into account the pulsating flow frequency variation. We also measure instantaneous pressure pulses within pipe line to identify the transfer functions. We conduct series of experiments to investigate the propagation characteristics of pressure pulse for various pressure of pulsating flow. The working fluid of the present study is ISO VG46 and the temperature ranges from 20 to $60^{\circ}$ with normal pressure at 4000kPa. The flow rate is measured by using an ultrasonic flow meter. Pressures at fixed upstream and downstream positions are measured concurrently. The electric signals of the pressure sensor are stored and analyzed using a system analyzer(PKE 983 series). The frequency is varied in the range of 10~500Hz. The Reynolds number is kept below 2,000. In the present study, boundary condition was varied by installing a surge tank and an orifice at the end of pipe. Experimental and theoretical results were compared each other under various boundary conditions.

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.

Development of Trimming Technology in High-fine Resistor Using U.V. Laser (자외선 레이저를 이용한 고정밀 저항체 가공기술 개발)

  • Noh, S.S.;Kim, D.H.;Chung, G.S.;Kim, H.P.;Kim, K.H.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.358-364
    • /
    • 2002
  • In this paper, we used U.V.(wavelength, 355nm) laser for adjusting Pt thin films temperature sensor to $100{\Omega}$ at $0^{\circ}C$. Internationally, A-class tolerance of temperature sensor is $0.06{\Omega}$ at $0^{\circ}C$. This is under value of $0.15^{\circ}C$, actually, so high-fine trimming technology is essential to this process. The width of trimmed lines was about $10{\mu}m$ and the best trimming of Pt thin films of $1{\sim}1.5{\mu}m$ was carried out with power : 35mW, rep. rate frequency : 200Hz and bite size : $1.5{\mu}m$. And using photolithography process, 96 resistors were fabricated in $2"{\times}2"$ substrate as the proportion of $79{\sim}90{\Omega}$ and $91{\sim}102{\Omega}$ is 42.7% and 57.3%, respectively. As result of trimming resistors to the target value of $109.73{\Omega}$ at $25^{\circ}C$, 82.3% of resistors had the tolerance within ${\pm}0.30{\Omega}$ and the others(17.7%) were within ${\pm}0.06{\Omega}$ of A-class tolerance.

A Study of the Planting Characteristics of Street Trees and Herbaceous Plants in Gangwon-do (강원도 내 가로수와 가로녹지대 초화류의 식재 특성에 관한 연구)

  • Jeong Jin-Hyung;Lee Ki-Eui
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.5 s.112
    • /
    • pp.57-68
    • /
    • 2005
  • This study surveyed planting areas along streets in Gangwon-do to find out how to improve the planting and use of street trees and herbaceous plants. There were 301,491 trees of 41 species on the streets of Gangwon-do in 2004. The predominant species of street trees were Ginkgo biloba ($40\%$), Prunus spp. (Prunus yedoensis and Prunus sargentii) ($25\%$), Platanus occidentalis ($5\%$), followed by Betula platyphylla var. japonica, Zelkova serrata, Prunus armeniaca var. ansu, Acer palmatum, and Pinus thunbergii. Eighty-four herbaceous plant species were found in the Youngseo district (the southern area of Gangwon-do); the ratio of native species to exotic was 51:33. The predominant species were Cosmos bipinnatus, Petunia hybrida, Tagetes spp., Aster koraiensis, and Fagopyrum esculentum. Eighty-nine herbaceous plant species were found in the Youngdong district (the eastern area of Gangwon-do); the ratio of native species to exotic was 55:33. The predominant herbaceous plants were Aster koraiensis, Tagetes spp., Petunia hybrida, Rudbeckia bicolor, Cosmos bipinnatus, Salvia splendens, Brassica oleraceae var. acephala, Aquilegia buergeriana var. oxysepala, Coreopsis drummondii, Viola tricolor, and Dianthus superbus var. longicalycinus. Appropriate pruning adds to the aesthetic value of trees and prolongs their useful life; it also maintains good health and thereby reduces the need to control insects and diseases. Street trees had not been properly pruned due to the presence of power lines and a shortage of pruning information. The pruning was controlled by Korea Electric Power Company, which has no pruning information. Pruning must be maintained by a professional landscape company in order to maintain good shape, such as that which is done for bonsai. In order to improve the planting, use and maintenance of landscape plants in Gangwon-do, the following recommendations are made: street tree species should be diversified, suitable street trees should be selected for each space, native species should generally be used, trees should be appropriately pruned and properly fertilized, pests and diseases should be controlled, plantings should be done in multiple layers, spatial arrangements should be improved, larger trees should be planted, and drainage and underground electric wires should be considered when planting.

A Study on Three-phase Imbalance of a Power Transmission Line due to Installation of a Passive Loop Conductor (수동루프에 의한 송전선로 상불평형 발생에 관한 연구)

  • 김종형;신명철;최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.31-38
    • /
    • 2003
  • Among mitigation techniques for electric and magnetic field (EMF) from an overhead transmission line a passive loop is a way that can be cheap and easily installed on the existing towers and have a satisfactory effect as well. However current induced in the passive loop causes transmission power loss and the phase imbalance increases since geometrical asymmetry of the transmission lines becomes larger. So in order to evaluate the power loss and the phase imbalance due to a passive loop, this paper represent a 345[kV] 1-circuit flat type transmission line as asymmetrical 3-phase distributed parameter line model where the effect of a passive loop is embedded in the line parameters, and then formulates differential equations. By solving these equations voltages and currents of each phase at receiving end become known. We find out that power losses occur differently at each phase and positive sequence component decreases at receiving end while negative sequence component increase. In general phase imbalance due to a passive loop is slight, but it increases in proportional to the induced current and length of section where the passive loop is installed. Thus the phase imbalance should be included in terms of cost for introducing a passive loop.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Calculation of Induced Current in the Human Body around 765 kV Transmission Lines (765 kV 초고압 송전선 주변의 인체 유도전류 계산)

  • 명성호;이재복;허창수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.802-812
    • /
    • 1998
  • Safety related to electric field exposure for the personnel of high voltage power plant and substation is of importance. To analyze the induced current influencing on human body in this paper, we calculate directly capacitance in three dimension which is complex and time consuming, as not to separate the voltage source and the induced object using a effective modeling technique. The proposed algorithm in this paper has been applied to 765 kV high voltage transmission line to evaluate human hazard for the induced current through the case study. As the results, the short circuit current of human body has been identified in the range of 0.3 mA to 6.8 mA. Closing to transmission line, this range of short current can exceed 5 mA that ANSI recommended let-go current. Therefore, it is necessary to countermeasure such as putting on conductive clothing in live-line maintenance of transmission line.

  • PDF

Research of Electrical Safety Test Construction about Structure under 765kV Transmission Lines (765kV 송전선로 선하 건조물 전기안전 실증시험 구축 연구)

  • Mun, Seong-duk;Maeng, Jong-ho;An, Ho-sung;Ahn, Heesung;Lee, Ho-guen
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.410-411
    • /
    • 2015
  • 765kV 송전선로와 선하 건조물은 최하단 도체의 높이 28m를 적용하고 대지저항률은 $100{\Omega}m$, IEEE 변전소 설계지침인 Std-80에 따라 건조물에 접촉하는 사람의 인체저항은 $1000{\Omega}m$, 대지를 딛고 있는 사람의 한쪽 발 접지저항은 직경 8cm의 원판 접지저항을 적용한다. 이렇게 구성된 모델에서 선로중심에서 건조물까지 이격거리 변동에 따라 인체 유도전류를 측정하고자 한다. 본 연구에서는 전기안전 실증시험을 위해 765kV 가공송전선로 직하에 목조 및 샌드위치 판넬 2가지 시험용 가옥을 설치하였다. 전기설비기술기준에 의거하여 선하직하 이격거리가 28m일 때 발생할 수 있는 전자계 특성과 재질에 따른 전자계가 미치는 영향을 비교 분석하고 장기 유도장해 실측 데이터를 확보하고자 그림 1과 같이 구축 설계하였다. 이를 통해 송전선로에 의해 선로중심으로부터 구축된 모의가옥까지 이격거리에 따라 유도되는 전류를 측정하고 그 크기가 인체에 미치는 유도전류 한계치 초과 여부에 대해 검토함으로써 안전성 여부에 대해 측정 및 검토하고자 시험게획을 수립하였다. 또한 선로 고장 시 대지전위상승에 의한 선하 건조물 안정성 검토 및 낙뢰서지 유입에 의한 전기안전 시험 구성을 하였다.

  • PDF