• Title/Summary/Keyword: Electric Power Lines

Search Result 485, Processing Time 0.028 seconds

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

A Study on the channel characteristics of the household AC power line used for the low bit rate communication home network (전력선 통신 응용을 위한 저압 댁내망의 채널 특성 분석 기법에 관한 연구)

  • Ahn, N.H.;Chang, T.G.;Hwang, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.305-307
    • /
    • 2001
  • In this paper, the household AC power line network is characterized for the low bit rate power line communication (PLC) in the frequency range from 10kHz to 450kHz. Various types of electric apparatus and the power lines constitute the network topology, and the PLC channel transfer function and the channel impedance are derived based on the constructed network topology. The channel characteristics derived with the lumped circuit model and the distributed circuit model are compared using the computer simulations. The effect of the wave reflection and signal distortions are also investigated.

  • PDF

Development of Performance Analysis System (NOPAS) for Turbine Cycle of Nuclear Power Plant

  • Kim, Seong-Kun;Park, Kwang-Hee
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.34-45
    • /
    • 2001
  • We have needs to develop a performance analysis system that can be used in domestic nuclear power plants to determine performance status of turbine cycle. We developed new NOPAS system to aid performance analysis of turbine cycle . Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on ASME (American Society of Mechanical Engineers) PTC (Performance Test Code). Robustness in the performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful aids for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis reports.

  • PDF

Development and Operation of Durability Mock-Up Test Facilities for Offshore Electricity Structures (해상 전력구조물 내구성 실증 실험장 구축 및 운영)

  • Pang Gi-Sung;Han Sang-Mook;Song Young-Chul;Kwon Byeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.265-268
    • /
    • 2005
  • This paper discusses a strategy and status for development and operation of durability mock-up test facilities for offshore structures. The strategy is examplified and facilitated using an offshore transmission tower crossing the West sea and the Shihwha lake, which was designed and constructed 345kV T/L lines transmitting power from Yeong-Heung fossil power plant to Seoul metropolitan area. Various data for corrosion protection, aging, life-prediction of concrete and steel offshore structures can be obtained using the proposed mock-up test facility. Acquired data will be used for further research on durability, life-prediction, and retrofit of structures. It is important to maintain the safety of 345 kV Yeong-Heung transmission line crossing the Shihwha lake because the offshore structure is one of the critical electric facilities transmitting large power to the metropolitan area. Operation of the offshore transmission tower mock-up is expected to make a significant contribution to stable power supply.

  • PDF

Measurement and Analysis of Line Impedance in Underground Cables (지중케이블 선로 임피던스 실측 및 분석)

  • Ha, C.W.;Kim, J.N.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.205-207
    • /
    • 2003
  • The line impedance is important data that is applied in all analysis fields of electric power system like power flow, fault current, stability and relay calculation etc. Usually, impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistance. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Therefore, the line impedance were measured for this study in an actual power system of underground cables, and were analyzed by a generalized circuit analysis program EMTP for comparison with the measured value. These analysis result is considered to become foundation of impedance calculation for underground cable.

  • PDF

Energy Storage Application Strategy on DC Electric Railroad System using a Novel Railroad Analysis Algorithm

  • Lee, Han-Sang;Lee, Han-Min;Lee, Chang-Mu;Jang, Gil-Soo;Kim, Gil-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.228-238
    • /
    • 2010
  • There is an increasing interest in research to help overcome the energy crisis that has been focused on energy storage applications in various parts of power systems. Energy storage systems are good at enhancing the reliability or improving the efficiency of a power system by creating a time gap between the generation and the consumption of power. As a contribution to the various applications of storage devices, this paper describes a novel algorithm that determines the power and storage capacity of selected energy storage devices in order to improve upon railroad system efficiency. The algorithm is also demonstrated by means of simulation studies for the Korean railroad lines now in service. A part of this novel algorithm includes the DC railroad powerflow algorithm that considers the mobility of railroad vehicles, which is necessary because the electric railroad system has a distinct distribution system where the location and power of vehicles are not fixed values. In order to derive a more accurate powerflow result, this algorithm has been designed to consider the rail voltage as well as the feeder voltage for calculating the vehicle voltage. By applying the resultant control scheme, the charging or discharging within a specific voltage boundary, energy savings and a substation voltage stabilization using storage devices are achieved at the same time.

Characterization of wind-induced vibrations in transmission lines by single-channel field data analysis

  • Yamaguchi, Hiroki;Gurung, Chandra B.;Yukino, Teruhiro
    • Wind and Structures
    • /
    • v.8 no.2
    • /
    • pp.121-134
    • /
    • 2005
  • Wind-induced vibrations measured in the Tsuruga Test Line are characterized in this paper by single-channel data analysis based on piecewise application of Prony's method. Some of events were identified as galloping, while most of events were buffeting responses, which were confirmed partly by the buffeting analysis. Effects of end condition etc. on the response characteristics are also discussed.

Analysis of Induced-Currant density Distribution in Spherical Human Model (자계에 의한 구형 인체모델 내부의 유도전류밀도 분포 해석)

  • Yeo, H.Ch.;Kim, B.K.;Park, S.H.;Kang, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.458-458
    • /
    • 2003
  • In this study the induced-current density distributions in spherical human model by the magnetic field from electric power lines were analysed with visualization and also the effects of phase difference between components of magneto field were investigated.

  • PDF

Exploration of underground utilities using method predicting an anomaly(II) - field application (전기비저항을 이용한 지하매설물 탐사(II) - 현장실험 중심으로)

  • Ryu, Hee Hwan;Cho, Seon Ah;Kim, Kyoung Yul;Cho, Gye Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.449-461
    • /
    • 2017
  • The uncertain existence and insufficient information of underground structures, such as pipe lines and cable tunnels, is causing many problems related to route plan, design, construction of new underground structures. The theoretical equations that is able to predict the location, size, and direction of underground structures through electric field analysis are suggested at the previous study (Ryu., 2015). Three field tests were performed for predicting the location, size, and direction of underground structures and the existence and size of sink-hole. Prediction results were reflected at the design and follow-up measures were performed.

Study on drawing up the integration method between combined information communication network design and information management system for Transportation-Power-Infrastructures on the electric vehicle (전기자동차 교통-전력-시설 통합 정보통신 네트워크 설계 및 정보관리시스템 간 연계 방안 수립에 관한 연구)

  • Choi, Yoon-Gun;Hwang, Tae-Hong;Kim, Geon-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.60-70
    • /
    • 2011
  • Vehicle location detection and wireless communication method have be designed along the same lines as GPS, CDMA and WLAN, which is based upon the selecting factors such as state-of-art technology trend, accuracy, stability, and economic feasibility, in order to select the optimum method of information communication networks for integrated "Transportation-Power-Facilities" on the electric bus. In addition, the key features of each alternative for an efficient linkage have been review and the integration methodology for linking among Transportation Charging Center, Transportation(ITS, BIS) Center and smart Grid Center has been drawn up based on a technical level of difficulty of each alternative, political and administrative difficulties, and expense justification.